Cargando…

Delayed diagnosis of a retained guidewire after bedside femoral venous catheter insertion: A preventable complication

Central venous catheter (CVC) insertion is a commonly performed procedure that is used for continuous invasive hemodynamic monitoring, fluid resuscitation, drug therapy, and hemodialysis. CVC placement can be associated with serious complications that are mostly preventable. One of these complicatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Almehmi, Sloan E., Abaza, Masa, Krishna, Vinay Narasimha, Almehmi, Ammar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8715130/
https://www.ncbi.nlm.nih.gov/pubmed/35027989
http://dx.doi.org/10.1016/j.radcr.2021.11.030
Descripción
Sumario:Central venous catheter (CVC) insertion is a commonly performed procedure that is used for continuous invasive hemodynamic monitoring, fluid resuscitation, drug therapy, and hemodialysis. CVC placement can be associated with serious complications that are mostly preventable. One of these complications is the loss of the guidewire within the intravascular space, which carries a high morbidity and mortality. Here, we describe a 44-year old patient who presented with acute kidney injury and metabolic derangements that necessitated bedside right femoral dialysis catheter to initiate emergent renal replacement therapy. A day after the catheter insertion, the guidewire was noted on a routine chest X-ray extending into the base of the skull. The clinical course was complicated with cerebral infarction. Subsequently, the retained guidewire was removed a few days after the CVC insertion. In summary, the retained guidewire within the circulation is associated with potentially life-threatening and hazardous outcomes. Continuing education, vigilant supervision, and implementing certain protocols are likely to prevent such undesirable events.