Cargando…

Transjugular Portosystemic Stent Shunt: Impact of Right Atrial Pressure on Portal Venous Hemodynamics Within the First Week

PURPOSE: Porto-systemic pressure gradient is used to prognosticate rebleeding and resolution of ascites after TIPS. This study investigates the reliability of portal pressure characteristics as quantified immediately after TIPS placement and at short-term control. PATIENTS AND METHODS: Portal venous...

Descripción completa

Detalles Bibliográficos
Autores principales: Pitton, Michael Bernhard, Weinmann, Arndt, Kloeckner, Roman, Mittler, Jens, Ruckes, Christian, Düber, Christoph, Otto, Gerd
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8716358/
https://www.ncbi.nlm.nih.gov/pubmed/34853873
http://dx.doi.org/10.1007/s00270-021-03003-z
Descripción
Sumario:PURPOSE: Porto-systemic pressure gradient is used to prognosticate rebleeding and resolution of ascites after TIPS. This study investigates the reliability of portal pressure characteristics as quantified immediately after TIPS placement and at short-term control. PATIENTS AND METHODS: Portal venous pressure (PVP) and right atrial pressure (RAP) were prospectively obtained before and after TIPS as well as ≥ 48 h after TIPS procedure. Porto-systemic pressure gradients (PSG) and pressure changes were calculated. A multivariate regression analysis was performed to predict portal hemodynamics at short-term control. RESULTS: The study included 124 consecutive patients. Indications for TIPS were refractory ascites, variceal bleeding or combinations of both. Pre- and post-interventional PSG yielded 16.4 ± 5.3 mmHg and 5.9 ± 2.7 mmHg, respectively. At that time, 105/124 patients (84.7%) met the target (PSG ≤ 8 mmHg). After 4 days (median), PSG was 8.5 ± 3.5 mmHg and only 66 patients (53%) met that target. In patients exceeding the target PSG at follow-up, PVP was significantly higher and RAP was lower resulting in the increased PSG. The highly variable changes of RAP were the main contributor to different pressure gradients. In the multivariate regression analysis, PVP and RAP immediately after TIPS were predictors for PSG at short-term control with moderately predictive capacity (AUC = 0.75). CONCLUSION: Besides the reduction of portal vein pressure, the highly variable right atrial pressure was the main contributor to different pressure gradients. Thus, immediate post-TIPS measurements do not reliably predict portal hemodynamics during follow-up. These findings need to be further investigated with respect to the corresponding clinical course of the patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00270-021-03003-z.