Cargando…
Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia
Purpose: To assess the 8-year clinical outcomes of implantation of an implantable collamer lens (ICL) with a central port (KS-Aquaport; EVO-ICL) for moderate to high myopia and myopic astigmatism. Methods: This retrospective study comprised a total of 177 eyes of 106 patients with spherical equivale...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8716586/ https://www.ncbi.nlm.nih.gov/pubmed/34977099 http://dx.doi.org/10.3389/fmed.2021.799078 |
_version_ | 1784624354373402624 |
---|---|
author | Kamiya, Kazutaka Shimizu, Kimiya Takahashi, Masahide Ando, Wakako Hayakawa, Hideki Shoji, Nobuyuki |
author_facet | Kamiya, Kazutaka Shimizu, Kimiya Takahashi, Masahide Ando, Wakako Hayakawa, Hideki Shoji, Nobuyuki |
author_sort | Kamiya, Kazutaka |
collection | PubMed |
description | Purpose: To assess the 8-year clinical outcomes of implantation of an implantable collamer lens (ICL) with a central port (KS-Aquaport; EVO-ICL) for moderate to high myopia and myopic astigmatism. Methods: This retrospective study comprised a total of 177 eyes of 106 patients with spherical equivalents of −7.99 ± 3.33 D [mean ± standard deviation], who underwent EVO-ICL implantation. We evaluated the safety, efficacy, predictability, stability, and adverse events of the surgery, at 1 month, and 1, 2, 4, 6, and 8 years postoperatively. Results: The logarithm of the minimal angle of resolution (LogMAR) uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were −0.07 ± 0.17 and −0.20 ± 0.09, respectively, at 8 years postoperatively. The safety and efficacy indices were 1.18 ± 0.24 and 0.89 ± 0.28, respectively. At 8 years, 83 and 93% eyes were within ± 0.5 D and ± 1.0 D of the targeted correction, respectively. Change in manifest refraction from 1 month to 8 years postoperatively was −0.13 ± 0.30 D. Three eyes (1.7%) that developed cataracts had a slight pre-existing peripheral anterior subcapsular cataract formation required simultaneous ICL extraction and cataract surgery at 2 or 3 years or ICL size change (1 size up) at 7 years postoperatively. We found that neither significant intraocular pressure (IOP) rise (including pupillary block) nor significant endothelial cell loss occurred in any case throughout the 8-year observation period. Conclusions: Current ICL implantation with central port technology offered good continuous outcomes for all measures of safety, efficacy, predictability, and stability for correcting moderate to high myopic errors over a long period, thereby suggesting its long-term viability as a surgical approach for the treatment of such eyes. |
format | Online Article Text |
id | pubmed-8716586 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-87165862021-12-31 Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia Kamiya, Kazutaka Shimizu, Kimiya Takahashi, Masahide Ando, Wakako Hayakawa, Hideki Shoji, Nobuyuki Front Med (Lausanne) Medicine Purpose: To assess the 8-year clinical outcomes of implantation of an implantable collamer lens (ICL) with a central port (KS-Aquaport; EVO-ICL) for moderate to high myopia and myopic astigmatism. Methods: This retrospective study comprised a total of 177 eyes of 106 patients with spherical equivalents of −7.99 ± 3.33 D [mean ± standard deviation], who underwent EVO-ICL implantation. We evaluated the safety, efficacy, predictability, stability, and adverse events of the surgery, at 1 month, and 1, 2, 4, 6, and 8 years postoperatively. Results: The logarithm of the minimal angle of resolution (LogMAR) uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were −0.07 ± 0.17 and −0.20 ± 0.09, respectively, at 8 years postoperatively. The safety and efficacy indices were 1.18 ± 0.24 and 0.89 ± 0.28, respectively. At 8 years, 83 and 93% eyes were within ± 0.5 D and ± 1.0 D of the targeted correction, respectively. Change in manifest refraction from 1 month to 8 years postoperatively was −0.13 ± 0.30 D. Three eyes (1.7%) that developed cataracts had a slight pre-existing peripheral anterior subcapsular cataract formation required simultaneous ICL extraction and cataract surgery at 2 or 3 years or ICL size change (1 size up) at 7 years postoperatively. We found that neither significant intraocular pressure (IOP) rise (including pupillary block) nor significant endothelial cell loss occurred in any case throughout the 8-year observation period. Conclusions: Current ICL implantation with central port technology offered good continuous outcomes for all measures of safety, efficacy, predictability, and stability for correcting moderate to high myopic errors over a long period, thereby suggesting its long-term viability as a surgical approach for the treatment of such eyes. Frontiers Media S.A. 2021-12-16 /pmc/articles/PMC8716586/ /pubmed/34977099 http://dx.doi.org/10.3389/fmed.2021.799078 Text en Copyright © 2021 Kamiya, Shimizu, Takahashi, Ando, Hayakawa and Shoji. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Kamiya, Kazutaka Shimizu, Kimiya Takahashi, Masahide Ando, Wakako Hayakawa, Hideki Shoji, Nobuyuki Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia |
title | Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia |
title_full | Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia |
title_fullStr | Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia |
title_full_unstemmed | Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia |
title_short | Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia |
title_sort | eight-year outcomes of implantation of posterior chamber phakic intraocular lens with a central port for moderate to high ametropia |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8716586/ https://www.ncbi.nlm.nih.gov/pubmed/34977099 http://dx.doi.org/10.3389/fmed.2021.799078 |
work_keys_str_mv | AT kamiyakazutaka eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia AT shimizukimiya eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia AT takahashimasahide eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia AT andowakako eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia AT hayakawahideki eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia AT shojinobuyuki eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia |