Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia

Purpose: To assess the 8-year clinical outcomes of implantation of an implantable collamer lens (ICL) with a central port (KS-Aquaport; EVO-ICL) for moderate to high myopia and myopic astigmatism. Methods: This retrospective study comprised a total of 177 eyes of 106 patients with spherical equivale...

Descripción completa

Detalles Bibliográficos
Autores principales: Kamiya, Kazutaka, Shimizu, Kimiya, Takahashi, Masahide, Ando, Wakako, Hayakawa, Hideki, Shoji, Nobuyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8716586/
https://www.ncbi.nlm.nih.gov/pubmed/34977099
http://dx.doi.org/10.3389/fmed.2021.799078
_version_ 1784624354373402624
author Kamiya, Kazutaka
Shimizu, Kimiya
Takahashi, Masahide
Ando, Wakako
Hayakawa, Hideki
Shoji, Nobuyuki
author_facet Kamiya, Kazutaka
Shimizu, Kimiya
Takahashi, Masahide
Ando, Wakako
Hayakawa, Hideki
Shoji, Nobuyuki
author_sort Kamiya, Kazutaka
collection PubMed
description Purpose: To assess the 8-year clinical outcomes of implantation of an implantable collamer lens (ICL) with a central port (KS-Aquaport; EVO-ICL) for moderate to high myopia and myopic astigmatism. Methods: This retrospective study comprised a total of 177 eyes of 106 patients with spherical equivalents of −7.99 ± 3.33 D [mean ± standard deviation], who underwent EVO-ICL implantation. We evaluated the safety, efficacy, predictability, stability, and adverse events of the surgery, at 1 month, and 1, 2, 4, 6, and 8 years postoperatively. Results: The logarithm of the minimal angle of resolution (LogMAR) uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were −0.07 ± 0.17 and −0.20 ± 0.09, respectively, at 8 years postoperatively. The safety and efficacy indices were 1.18 ± 0.24 and 0.89 ± 0.28, respectively. At 8 years, 83 and 93% eyes were within ± 0.5 D and ± 1.0 D of the targeted correction, respectively. Change in manifest refraction from 1 month to 8 years postoperatively was −0.13 ± 0.30 D. Three eyes (1.7%) that developed cataracts had a slight pre-existing peripheral anterior subcapsular cataract formation required simultaneous ICL extraction and cataract surgery at 2 or 3 years or ICL size change (1 size up) at 7 years postoperatively. We found that neither significant intraocular pressure (IOP) rise (including pupillary block) nor significant endothelial cell loss occurred in any case throughout the 8-year observation period. Conclusions: Current ICL implantation with central port technology offered good continuous outcomes for all measures of safety, efficacy, predictability, and stability for correcting moderate to high myopic errors over a long period, thereby suggesting its long-term viability as a surgical approach for the treatment of such eyes.
format Online
Article
Text
id pubmed-8716586
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87165862021-12-31 Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia Kamiya, Kazutaka Shimizu, Kimiya Takahashi, Masahide Ando, Wakako Hayakawa, Hideki Shoji, Nobuyuki Front Med (Lausanne) Medicine Purpose: To assess the 8-year clinical outcomes of implantation of an implantable collamer lens (ICL) with a central port (KS-Aquaport; EVO-ICL) for moderate to high myopia and myopic astigmatism. Methods: This retrospective study comprised a total of 177 eyes of 106 patients with spherical equivalents of −7.99 ± 3.33 D [mean ± standard deviation], who underwent EVO-ICL implantation. We evaluated the safety, efficacy, predictability, stability, and adverse events of the surgery, at 1 month, and 1, 2, 4, 6, and 8 years postoperatively. Results: The logarithm of the minimal angle of resolution (LogMAR) uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were −0.07 ± 0.17 and −0.20 ± 0.09, respectively, at 8 years postoperatively. The safety and efficacy indices were 1.18 ± 0.24 and 0.89 ± 0.28, respectively. At 8 years, 83 and 93% eyes were within ± 0.5 D and ± 1.0 D of the targeted correction, respectively. Change in manifest refraction from 1 month to 8 years postoperatively was −0.13 ± 0.30 D. Three eyes (1.7%) that developed cataracts had a slight pre-existing peripheral anterior subcapsular cataract formation required simultaneous ICL extraction and cataract surgery at 2 or 3 years or ICL size change (1 size up) at 7 years postoperatively. We found that neither significant intraocular pressure (IOP) rise (including pupillary block) nor significant endothelial cell loss occurred in any case throughout the 8-year observation period. Conclusions: Current ICL implantation with central port technology offered good continuous outcomes for all measures of safety, efficacy, predictability, and stability for correcting moderate to high myopic errors over a long period, thereby suggesting its long-term viability as a surgical approach for the treatment of such eyes. Frontiers Media S.A. 2021-12-16 /pmc/articles/PMC8716586/ /pubmed/34977099 http://dx.doi.org/10.3389/fmed.2021.799078 Text en Copyright © 2021 Kamiya, Shimizu, Takahashi, Ando, Hayakawa and Shoji. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Kamiya, Kazutaka
Shimizu, Kimiya
Takahashi, Masahide
Ando, Wakako
Hayakawa, Hideki
Shoji, Nobuyuki
Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia
title Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia
title_full Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia
title_fullStr Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia
title_full_unstemmed Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia
title_short Eight-Year Outcomes of Implantation of Posterior Chamber Phakic Intraocular Lens With a Central Port for Moderate to High Ametropia
title_sort eight-year outcomes of implantation of posterior chamber phakic intraocular lens with a central port for moderate to high ametropia
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8716586/
https://www.ncbi.nlm.nih.gov/pubmed/34977099
http://dx.doi.org/10.3389/fmed.2021.799078
work_keys_str_mv AT kamiyakazutaka eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia
AT shimizukimiya eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia
AT takahashimasahide eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia
AT andowakako eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia
AT hayakawahideki eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia
AT shojinobuyuki eightyearoutcomesofimplantationofposteriorchamberphakicintraocularlenswithacentralportformoderatetohighametropia