Cargando…

A Novel and Clinically Feasible Instrument for Quantifying Upper Limb Muscle Tone and Motor Function via Indirect Measure Methods

Objective: Quantifying muscle tone is often based on a tester’s subjective judgment in clinical settings. There is, however, a lack of suitable tools that can be used to objectively assess muscle tone. This study thus introduces a reliable, clinically-feasible device, called the Arm Circumference Mo...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8719648/
https://www.ncbi.nlm.nih.gov/pubmed/34984110
http://dx.doi.org/10.1109/JTEHM.2021.3136754
_version_ 1784624978913656832
collection PubMed
description Objective: Quantifying muscle tone is often based on a tester’s subjective judgment in clinical settings. There is, however, a lack of suitable tools that can be used to objectively assess muscle tone. This study thus introduces a reliable, clinically-feasible device, called the Arm Circumference Motor Evaluation System (ACMES), for quantifying the muscle tone of upper limbs without using mechanical torque transducers. Methods: While the ACMES conducts continuously passive arm circumduction motions, the voltage and current of the driving motor is transduced into torque values via a least square approximation. A torque sensor and springs with different spring constants were used for the validity and reliability test in the first part of this study. Fifteen healthy adults and two patients who had experienced a stroke participated in the second part, which was a clinical experiment used to examine the in-vivo test-retest reliability and to explore the inspection differences between healthy and patient participants. Results: The results showed that the ACMES has high validity (R(2): ~0.99) and reliability (R(2): 0.96~0.99). The reliability of the ACMES used on human subjects was acceptable (R(2): 0.83~0.85). The various muscle tone patterns could be found among healthy and stroke subjects via the ACMES. Conclusion: Clinically, abnormal muscle tone, which seriously affects motion performance, will be found in many diagnoses, such as stroke or cerebral palsy. However, objectively and feasibly measuring abnormal tone in modern clinical settings is still a challenging task. Thus, the ACMES was developed and tested to verify its feasibility as a measurement system for detecting the mechanical torque associated with muscle tone.
format Online
Article
Text
id pubmed-8719648
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-87196482022-01-03 A Novel and Clinically Feasible Instrument for Quantifying Upper Limb Muscle Tone and Motor Function via Indirect Measure Methods IEEE J Transl Eng Health Med Article Objective: Quantifying muscle tone is often based on a tester’s subjective judgment in clinical settings. There is, however, a lack of suitable tools that can be used to objectively assess muscle tone. This study thus introduces a reliable, clinically-feasible device, called the Arm Circumference Motor Evaluation System (ACMES), for quantifying the muscle tone of upper limbs without using mechanical torque transducers. Methods: While the ACMES conducts continuously passive arm circumduction motions, the voltage and current of the driving motor is transduced into torque values via a least square approximation. A torque sensor and springs with different spring constants were used for the validity and reliability test in the first part of this study. Fifteen healthy adults and two patients who had experienced a stroke participated in the second part, which was a clinical experiment used to examine the in-vivo test-retest reliability and to explore the inspection differences between healthy and patient participants. Results: The results showed that the ACMES has high validity (R(2): ~0.99) and reliability (R(2): 0.96~0.99). The reliability of the ACMES used on human subjects was acceptable (R(2): 0.83~0.85). The various muscle tone patterns could be found among healthy and stroke subjects via the ACMES. Conclusion: Clinically, abnormal muscle tone, which seriously affects motion performance, will be found in many diagnoses, such as stroke or cerebral palsy. However, objectively and feasibly measuring abnormal tone in modern clinical settings is still a challenging task. Thus, the ACMES was developed and tested to verify its feasibility as a measurement system for detecting the mechanical torque associated with muscle tone. IEEE 2021-12-20 /pmc/articles/PMC8719648/ /pubmed/34984110 http://dx.doi.org/10.1109/JTEHM.2021.3136754 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. For more information, see https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Article
A Novel and Clinically Feasible Instrument for Quantifying Upper Limb Muscle Tone and Motor Function via Indirect Measure Methods
title A Novel and Clinically Feasible Instrument for Quantifying Upper Limb Muscle Tone and Motor Function via Indirect Measure Methods
title_full A Novel and Clinically Feasible Instrument for Quantifying Upper Limb Muscle Tone and Motor Function via Indirect Measure Methods
title_fullStr A Novel and Clinically Feasible Instrument for Quantifying Upper Limb Muscle Tone and Motor Function via Indirect Measure Methods
title_full_unstemmed A Novel and Clinically Feasible Instrument for Quantifying Upper Limb Muscle Tone and Motor Function via Indirect Measure Methods
title_short A Novel and Clinically Feasible Instrument for Quantifying Upper Limb Muscle Tone and Motor Function via Indirect Measure Methods
title_sort novel and clinically feasible instrument for quantifying upper limb muscle tone and motor function via indirect measure methods
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8719648/
https://www.ncbi.nlm.nih.gov/pubmed/34984110
http://dx.doi.org/10.1109/JTEHM.2021.3136754
work_keys_str_mv AT anovelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT anovelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT anovelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT anovelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT anovelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT anovelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT anovelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT anovelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT novelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT novelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT novelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT novelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT novelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT novelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT novelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods
AT novelandclinicallyfeasibleinstrumentforquantifyingupperlimbmuscletoneandmotorfunctionviaindirectmeasuremethods