Preliminary Analysis of a Wireless and Wearable Electronic-Textile EASI-Based Electrocardiogram

Background: With cardiovascular disease continuing to be the leading cause of death and the primary reason for hospitalization worldwide, there is an increased burden on healthcare facilities. Electronic-textile (e-textile)-based cardiac monitoring offers a viable option to allow cardiac rehabilitat...

Descripción completa

Detalles Bibliográficos
Autores principales: Teferra, Meseret N., Hobbs, David A., Clark, Robyn A., Reynolds, Karen J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8720778/
https://www.ncbi.nlm.nih.gov/pubmed/34988133
http://dx.doi.org/10.3389/fcvm.2021.806726
_version_ 1784625196853886976
author Teferra, Meseret N.
Hobbs, David A.
Clark, Robyn A.
Reynolds, Karen J.
author_facet Teferra, Meseret N.
Hobbs, David A.
Clark, Robyn A.
Reynolds, Karen J.
author_sort Teferra, Meseret N.
collection PubMed
description Background: With cardiovascular disease continuing to be the leading cause of death and the primary reason for hospitalization worldwide, there is an increased burden on healthcare facilities. Electronic-textile (e-textile)-based cardiac monitoring offers a viable option to allow cardiac rehabilitation programs to be conducted outside of the hospital. Objectives: This study aimed to determine whether signals produced by an e-textile ECG monitor with textile electrodes in an EASI configuration are of sufficient quality to be used for cardiac monitoring. Specific objectives were to investigate the effect of the textile electrode characteristics, placement, and condition on signal quality, and finally to compare results to a reference ECG obtained from a current clinical standard the Holter monitor. Methods: ECGs during different body movements (yawning, deep-breathing, coughing, sideways, and up movement) and activities of daily living (sitting, sitting/standing from a chair, and climbing stairs) were collected from a baseline standard of normal healthy adult male using a novel e-textile ECG and a reference Holter monitor. Each movement or activity was recorded for 5 min with 2-min intervals between each recording. Three different textile area electrodes (40, 60, and 70 mm(2)) and electrode thicknesses (3, 5, and 10 mm) were considered in the experiment. The effect of electrode placement within the EASI configuration was also studied. Different signal quality parameters, including signal to noise ratio, approximate entropy, baseline power signal quality index, and QRS duration and QT intervals, were used to evaluate the accuracy and reliability of the textile-based ECG monitor. Results: The overall signal quality from the 70 mm(2) textile electrodes was higher compared to the smaller area electrodes. Results showed that the ECGs from 3 and 5 mm textile electrodes showed good quality. Regarding location, placing the “A” and “I” electrodes on the left and right anterior axillary points, respectively, showed higher signal quality compared to the standard EASI electrode placement. Wet textile electrodes showed better signal quality compared to their dry counterparts. When compared to the traditional Holter monitor, there was no significant difference in signal quality, which indicated textile monitoring was as good as current clinical standards (non-inferior). Conclusion: The e-textile EASI ECG monitor could be a viable option for real-time monitoring of cardiac activities. A clinical trial in a larger sample is recommended to validate the results in a clinical population.
format Online
Article
Text
id pubmed-8720778
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87207782022-01-04 Preliminary Analysis of a Wireless and Wearable Electronic-Textile EASI-Based Electrocardiogram Teferra, Meseret N. Hobbs, David A. Clark, Robyn A. Reynolds, Karen J. Front Cardiovasc Med Cardiovascular Medicine Background: With cardiovascular disease continuing to be the leading cause of death and the primary reason for hospitalization worldwide, there is an increased burden on healthcare facilities. Electronic-textile (e-textile)-based cardiac monitoring offers a viable option to allow cardiac rehabilitation programs to be conducted outside of the hospital. Objectives: This study aimed to determine whether signals produced by an e-textile ECG monitor with textile electrodes in an EASI configuration are of sufficient quality to be used for cardiac monitoring. Specific objectives were to investigate the effect of the textile electrode characteristics, placement, and condition on signal quality, and finally to compare results to a reference ECG obtained from a current clinical standard the Holter monitor. Methods: ECGs during different body movements (yawning, deep-breathing, coughing, sideways, and up movement) and activities of daily living (sitting, sitting/standing from a chair, and climbing stairs) were collected from a baseline standard of normal healthy adult male using a novel e-textile ECG and a reference Holter monitor. Each movement or activity was recorded for 5 min with 2-min intervals between each recording. Three different textile area electrodes (40, 60, and 70 mm(2)) and electrode thicknesses (3, 5, and 10 mm) were considered in the experiment. The effect of electrode placement within the EASI configuration was also studied. Different signal quality parameters, including signal to noise ratio, approximate entropy, baseline power signal quality index, and QRS duration and QT intervals, were used to evaluate the accuracy and reliability of the textile-based ECG monitor. Results: The overall signal quality from the 70 mm(2) textile electrodes was higher compared to the smaller area electrodes. Results showed that the ECGs from 3 and 5 mm textile electrodes showed good quality. Regarding location, placing the “A” and “I” electrodes on the left and right anterior axillary points, respectively, showed higher signal quality compared to the standard EASI electrode placement. Wet textile electrodes showed better signal quality compared to their dry counterparts. When compared to the traditional Holter monitor, there was no significant difference in signal quality, which indicated textile monitoring was as good as current clinical standards (non-inferior). Conclusion: The e-textile EASI ECG monitor could be a viable option for real-time monitoring of cardiac activities. A clinical trial in a larger sample is recommended to validate the results in a clinical population. Frontiers Media S.A. 2021-12-20 /pmc/articles/PMC8720778/ /pubmed/34988133 http://dx.doi.org/10.3389/fcvm.2021.806726 Text en Copyright © 2021 Teferra, Hobbs, Clark and Reynolds. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Teferra, Meseret N.
Hobbs, David A.
Clark, Robyn A.
Reynolds, Karen J.
Preliminary Analysis of a Wireless and Wearable Electronic-Textile EASI-Based Electrocardiogram
title Preliminary Analysis of a Wireless and Wearable Electronic-Textile EASI-Based Electrocardiogram
title_full Preliminary Analysis of a Wireless and Wearable Electronic-Textile EASI-Based Electrocardiogram
title_fullStr Preliminary Analysis of a Wireless and Wearable Electronic-Textile EASI-Based Electrocardiogram
title_full_unstemmed Preliminary Analysis of a Wireless and Wearable Electronic-Textile EASI-Based Electrocardiogram
title_short Preliminary Analysis of a Wireless and Wearable Electronic-Textile EASI-Based Electrocardiogram
title_sort preliminary analysis of a wireless and wearable electronic-textile easi-based electrocardiogram
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8720778/
https://www.ncbi.nlm.nih.gov/pubmed/34988133
http://dx.doi.org/10.3389/fcvm.2021.806726
work_keys_str_mv AT teferrameseretn preliminaryanalysisofawirelessandwearableelectronictextileeasibasedelectrocardiogram
AT hobbsdavida preliminaryanalysisofawirelessandwearableelectronictextileeasibasedelectrocardiogram
AT clarkrobyna preliminaryanalysisofawirelessandwearableelectronictextileeasibasedelectrocardiogram
AT reynoldskarenj preliminaryanalysisofawirelessandwearableelectronictextileeasibasedelectrocardiogram