Cargando…

Bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique

We present a case of bifurcation percutaneous coronary intervention (PCI) of the left main trunk (LMT) using a proximal balloon edge dilation (PBED) technique following a proximal optimizing technique (POT). The procedure of the PBED technique entailed precise positioning of the balloon for SB dilat...

Descripción completa

Detalles Bibliográficos
Autores principales: Kume, Teruyoshi, Koto, Satoshi, Sudo, Yasuyuki, Hiroshi, Okamoto, Yamada, Ryotaro, Imai, Koichiro, Koyama, Terumasa, Tamada, Tomoko, Neishi, Yoji, Uemura, Shiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese College of Cardiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8721264/
https://www.ncbi.nlm.nih.gov/pubmed/35024065
http://dx.doi.org/10.1016/j.jccase.2021.06.002
_version_ 1784625301088632832
author Kume, Teruyoshi
Koto, Satoshi
Sudo, Yasuyuki
Hiroshi, Okamoto
Yamada, Ryotaro
Imai, Koichiro
Koyama, Terumasa
Tamada, Tomoko
Neishi, Yoji
Uemura, Shiro
author_facet Kume, Teruyoshi
Koto, Satoshi
Sudo, Yasuyuki
Hiroshi, Okamoto
Yamada, Ryotaro
Imai, Koichiro
Koyama, Terumasa
Tamada, Tomoko
Neishi, Yoji
Uemura, Shiro
author_sort Kume, Teruyoshi
collection PubMed
description We present a case of bifurcation percutaneous coronary intervention (PCI) of the left main trunk (LMT) using a proximal balloon edge dilation (PBED) technique following a proximal optimizing technique (POT). The procedure of the PBED technique entailed precise positioning of the balloon for SB dilation, with the proximal radiopaque marker lying in the cross-sectional plane of the stent struts at the left circumflex artery (LCx) ostium. The PBED technique might prevent stent deformation induced by side branch (SB) dilation and eliminates the need for the second POT procedure in the re-POT sequence. In fact, three-dimensional reconstruction of optical coherence tomography (3D-OCT) revealed good opening of stent cells overlying the LCx ostium without deformation of stent struts causing incomplete stent apposition at the site opposite the LCx, so the second POT procedure was unnecessary in this case. <Learning objective: This is the first case report to describe bifurcation PCI of the LMT using POT-PBED procedures under 3D-OCT guidance. POT-PBED procedures might offer excellent acute results for cross-over single-stent implantation in LMT bifurcation lesions and could eliminate the second POT procedure in the re-POT sequence.>
format Online
Article
Text
id pubmed-8721264
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Japanese College of Cardiology
record_format MEDLINE/PubMed
spelling pubmed-87212642022-01-11 Bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique Kume, Teruyoshi Koto, Satoshi Sudo, Yasuyuki Hiroshi, Okamoto Yamada, Ryotaro Imai, Koichiro Koyama, Terumasa Tamada, Tomoko Neishi, Yoji Uemura, Shiro J Cardiol Cases Case Report We present a case of bifurcation percutaneous coronary intervention (PCI) of the left main trunk (LMT) using a proximal balloon edge dilation (PBED) technique following a proximal optimizing technique (POT). The procedure of the PBED technique entailed precise positioning of the balloon for SB dilation, with the proximal radiopaque marker lying in the cross-sectional plane of the stent struts at the left circumflex artery (LCx) ostium. The PBED technique might prevent stent deformation induced by side branch (SB) dilation and eliminates the need for the second POT procedure in the re-POT sequence. In fact, three-dimensional reconstruction of optical coherence tomography (3D-OCT) revealed good opening of stent cells overlying the LCx ostium without deformation of stent struts causing incomplete stent apposition at the site opposite the LCx, so the second POT procedure was unnecessary in this case. <Learning objective: This is the first case report to describe bifurcation PCI of the LMT using POT-PBED procedures under 3D-OCT guidance. POT-PBED procedures might offer excellent acute results for cross-over single-stent implantation in LMT bifurcation lesions and could eliminate the second POT procedure in the re-POT sequence.> Japanese College of Cardiology 2021-07-03 /pmc/articles/PMC8721264/ /pubmed/35024065 http://dx.doi.org/10.1016/j.jccase.2021.06.002 Text en © 2021 Japanese College of Cardiology. Published by Elsevier Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Case Report
Kume, Teruyoshi
Koto, Satoshi
Sudo, Yasuyuki
Hiroshi, Okamoto
Yamada, Ryotaro
Imai, Koichiro
Koyama, Terumasa
Tamada, Tomoko
Neishi, Yoji
Uemura, Shiro
Bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique
title Bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique
title_full Bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique
title_fullStr Bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique
title_full_unstemmed Bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique
title_short Bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique
title_sort bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8721264/
https://www.ncbi.nlm.nih.gov/pubmed/35024065
http://dx.doi.org/10.1016/j.jccase.2021.06.002
work_keys_str_mv AT kumeteruyoshi bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique
AT kotosatoshi bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique
AT sudoyasuyuki bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique
AT hiroshiokamoto bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique
AT yamadaryotaro bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique
AT imaikoichiro bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique
AT koyamaterumasa bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique
AT tamadatomoko bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique
AT neishiyoji bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique
AT uemurashiro bifurcationpercutaneouscoronaryinterventionofleftmaintrunktreatedusingaproximaloptimizingtechniqueandproximalballoonedgedilationtechnique