Cargando…

Europium Fluorescent Nanoparticles-Based Multiplex Lateral Flow Immunoassay for Simultaneous Detection of Three Antibiotic Families Residue

A fluorescent immunoassay based on europium nanoparticles (EuNPs-FIA) was developed for the simultaneous detection of antibiotic residues, solving the problems of single target detection and low sensitivity of traditional immunoassay methods. In the EuNPs-FIA, EuNPs were used as indictive probes by...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yaping, Ma, Biao, Liu, Miaomiao, Chen, Erjing, Xu, Ying, Zhang, Mingzhou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8722402/
https://www.ncbi.nlm.nih.gov/pubmed/34988061
http://dx.doi.org/10.3389/fchem.2021.793355
_version_ 1784625519117991936
author Wang, Yaping
Ma, Biao
Liu, Miaomiao
Chen, Erjing
Xu, Ying
Zhang, Mingzhou
author_facet Wang, Yaping
Ma, Biao
Liu, Miaomiao
Chen, Erjing
Xu, Ying
Zhang, Mingzhou
author_sort Wang, Yaping
collection PubMed
description A fluorescent immunoassay based on europium nanoparticles (EuNPs-FIA) was developed for the simultaneous detection of antibiotic residues, solving the problems of single target detection and low sensitivity of traditional immunoassay methods. In the EuNPs-FIA, EuNPs were used as indictive probes by binding to anti-tetracyclines monoclonal antibodies (anti-TCs mAb), anti-sulphonamides monoclonal antibodies (anti-SAs mAb) and anti-fluoroquinolones monoclonal antibodies (anti-FQs mAb), respectively. Different artificial antigens were assigned to different regions of the nitrocellulose membrane as capture reagents. The EuNPs-FIA allowed for the simultaneous detection of three classes of antibiotics (tetracyclines, fluoroquinolones and sulphonamides) within 15 min. It enabled both the qualitative determination with the naked eye under UV light and the quantitative detection of target antibiotics by scanning the fluorescence intensity of the detection probes on the corresponding detection lines. For qualitative analysis, the cut-off values for tetracyclines (TCs), fluoroquinolones (FQs) and sulphonamides (SAs) were 3.2 ng/ml, 2.4 ng/ml and 4.0 ng/ml, respectively, which were much lower than the maximum residue limit in food. For quantitative analysis, these ranged from 0.06 to 6.85 ng/ml for TCs, 0.03–5.14 ng/ml for FQs, and 0.04–4.40 ng/ml for SAs. The linear correlation coefficients were higher than 0.97. The mean spiked recoveries ranged from 92.1 to 106.2% with relative standard deviations less than 8.75%. Among them, the three monoclonal antibodies could recognize four types of TCs, seven types of FQs and 13 types of SAs, respectively, and the detection range could cover 24 antibiotic residues with different structural formulations. The results of the detection of antibiotic residues in real samples using this method were highly correlated with those of high performance liquid chromatography (R (2) > 0.98). The accuracy and precision of the EuNPs-FIA also met the requirements for quantitative analysis. These results suggested that this multiplex immunoassay method was a promising method for rapid screening of three families of antibiotic residues.
format Online
Article
Text
id pubmed-8722402
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87224022022-01-04 Europium Fluorescent Nanoparticles-Based Multiplex Lateral Flow Immunoassay for Simultaneous Detection of Three Antibiotic Families Residue Wang, Yaping Ma, Biao Liu, Miaomiao Chen, Erjing Xu, Ying Zhang, Mingzhou Front Chem Chemistry A fluorescent immunoassay based on europium nanoparticles (EuNPs-FIA) was developed for the simultaneous detection of antibiotic residues, solving the problems of single target detection and low sensitivity of traditional immunoassay methods. In the EuNPs-FIA, EuNPs were used as indictive probes by binding to anti-tetracyclines monoclonal antibodies (anti-TCs mAb), anti-sulphonamides monoclonal antibodies (anti-SAs mAb) and anti-fluoroquinolones monoclonal antibodies (anti-FQs mAb), respectively. Different artificial antigens were assigned to different regions of the nitrocellulose membrane as capture reagents. The EuNPs-FIA allowed for the simultaneous detection of three classes of antibiotics (tetracyclines, fluoroquinolones and sulphonamides) within 15 min. It enabled both the qualitative determination with the naked eye under UV light and the quantitative detection of target antibiotics by scanning the fluorescence intensity of the detection probes on the corresponding detection lines. For qualitative analysis, the cut-off values for tetracyclines (TCs), fluoroquinolones (FQs) and sulphonamides (SAs) were 3.2 ng/ml, 2.4 ng/ml and 4.0 ng/ml, respectively, which were much lower than the maximum residue limit in food. For quantitative analysis, these ranged from 0.06 to 6.85 ng/ml for TCs, 0.03–5.14 ng/ml for FQs, and 0.04–4.40 ng/ml for SAs. The linear correlation coefficients were higher than 0.97. The mean spiked recoveries ranged from 92.1 to 106.2% with relative standard deviations less than 8.75%. Among them, the three monoclonal antibodies could recognize four types of TCs, seven types of FQs and 13 types of SAs, respectively, and the detection range could cover 24 antibiotic residues with different structural formulations. The results of the detection of antibiotic residues in real samples using this method were highly correlated with those of high performance liquid chromatography (R (2) > 0.98). The accuracy and precision of the EuNPs-FIA also met the requirements for quantitative analysis. These results suggested that this multiplex immunoassay method was a promising method for rapid screening of three families of antibiotic residues. Frontiers Media S.A. 2021-12-20 /pmc/articles/PMC8722402/ /pubmed/34988061 http://dx.doi.org/10.3389/fchem.2021.793355 Text en Copyright © 2021 Wang, Ma, Liu, Chen, Xu and Zhang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Chemistry
Wang, Yaping
Ma, Biao
Liu, Miaomiao
Chen, Erjing
Xu, Ying
Zhang, Mingzhou
Europium Fluorescent Nanoparticles-Based Multiplex Lateral Flow Immunoassay for Simultaneous Detection of Three Antibiotic Families Residue
title Europium Fluorescent Nanoparticles-Based Multiplex Lateral Flow Immunoassay for Simultaneous Detection of Three Antibiotic Families Residue
title_full Europium Fluorescent Nanoparticles-Based Multiplex Lateral Flow Immunoassay for Simultaneous Detection of Three Antibiotic Families Residue
title_fullStr Europium Fluorescent Nanoparticles-Based Multiplex Lateral Flow Immunoassay for Simultaneous Detection of Three Antibiotic Families Residue
title_full_unstemmed Europium Fluorescent Nanoparticles-Based Multiplex Lateral Flow Immunoassay for Simultaneous Detection of Three Antibiotic Families Residue
title_short Europium Fluorescent Nanoparticles-Based Multiplex Lateral Flow Immunoassay for Simultaneous Detection of Three Antibiotic Families Residue
title_sort europium fluorescent nanoparticles-based multiplex lateral flow immunoassay for simultaneous detection of three antibiotic families residue
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8722402/
https://www.ncbi.nlm.nih.gov/pubmed/34988061
http://dx.doi.org/10.3389/fchem.2021.793355
work_keys_str_mv AT wangyaping europiumfluorescentnanoparticlesbasedmultiplexlateralflowimmunoassayforsimultaneousdetectionofthreeantibioticfamiliesresidue
AT mabiao europiumfluorescentnanoparticlesbasedmultiplexlateralflowimmunoassayforsimultaneousdetectionofthreeantibioticfamiliesresidue
AT liumiaomiao europiumfluorescentnanoparticlesbasedmultiplexlateralflowimmunoassayforsimultaneousdetectionofthreeantibioticfamiliesresidue
AT chenerjing europiumfluorescentnanoparticlesbasedmultiplexlateralflowimmunoassayforsimultaneousdetectionofthreeantibioticfamiliesresidue
AT xuying europiumfluorescentnanoparticlesbasedmultiplexlateralflowimmunoassayforsimultaneousdetectionofthreeantibioticfamiliesresidue
AT zhangmingzhou europiumfluorescentnanoparticlesbasedmultiplexlateralflowimmunoassayforsimultaneousdetectionofthreeantibioticfamiliesresidue