Cargando…
Clinical Safety and Outcomes of a Novel Ultrasound Assisted Bioabsorbable Suture Anchor in Foot and Ankle Surgeries
CATEGORY: Sports INTRODUCTION/PURPOSE: Bioabsorbable suture anchors have been popularized due to potential for osseous integration, less interference with diagnostic imaging, and ease of use. Recently, ultrasound assisted suture anchor systems have been introduced with the benefits of obtaining inte...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8723164/ http://dx.doi.org/10.1177/2473011420S00164 |
_version_ | 1784625654276292608 |
---|---|
author | Chen, Jie Sharma, Akhil Akoh, Craig C. Kadakia, Rishin J. Parekh, Selene G. |
author_facet | Chen, Jie Sharma, Akhil Akoh, Craig C. Kadakia, Rishin J. Parekh, Selene G. |
author_sort | Chen, Jie |
collection | PubMed |
description | CATEGORY: Sports INTRODUCTION/PURPOSE: Bioabsorbable suture anchors have been popularized due to potential for osseous integration, less interference with diagnostic imaging, and ease of use. Recently, ultrasound assisted suture anchor systems have been introduced with the benefits of obtaining interdigitation with cancellous bone while maintaining a minimal footprint. In a cadaveric study, ultrasound assisted suture anchors demonstrated a similar pullout strength and less system displacement when compared to a benchmark bioabsorbable anchor system. However, the failure and complication rates of ultrasound assisted bioabsorbable anchors has never been demonstrated in a clinical setting. We studied the Stryker SonicAnchor by examining complication rates in foot and ankle procedures and secondarily determined the efficacy by evaluating clinical outcomes of surgeries using this anchor system. METHODS: A retrospective analysis was performed on all patients treated by the primary investigator using the Stryker SutureAnchor between the dates of May 2016 and February 2018. We included all patients for which the anchor was used during surgery with at least 2 year followup including VAS and FAOS scores. We recorded baseline demographic information as well as the type of surgery patients underwent. We recorded all intraoperative and postoperative complications for these surgeries. In addition, we compared preoperative and postoperative clinical scores. RESULTS: 57 patients met inclusion criteria. On average, patients were 53 years old at the time of surgery. Mean followup was 32.8 months. Mean BMI was 30.36. Three patients reported current tobacco use (5.3%), four patients (7.0%) had type II diabetes mellitus at the time of their surgery, and only one patient (1.8%) had osteoporosis. Common procedures were Achilles repair including Haglund’s resection, peroneal surgery, and lateral ligament reconstruction. There were two deep infections requiring reoperation, one medial malleolus stress fracture following total ankle replacement, one metatarsal stress fracture not involving the surgery site, and one DVT. No reports of anchor pullout or soft tissue repair failure. VAS and FAOS scores improved from 6.2 to 1.2 and 54.3 to 93.9. CONCLUSION: In our review of 57 patients operated on with the SonicAnchor with at least two year followup, there were zero cases of complications stemming from the anchor including anchor pullout or soft tissue repair failure. Overall, patients improved tremendously in their clinical outcome scores across a wide range of different procedures. Previous studies have demonstrated the biomechanical strength of the SonicAnchor and our review supports its clinical safety and efficacy in long-term clinical followup. |
format | Online Article Text |
id | pubmed-8723164 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-87231642022-01-28 Clinical Safety and Outcomes of a Novel Ultrasound Assisted Bioabsorbable Suture Anchor in Foot and Ankle Surgeries Chen, Jie Sharma, Akhil Akoh, Craig C. Kadakia, Rishin J. Parekh, Selene G. Foot Ankle Orthop Article CATEGORY: Sports INTRODUCTION/PURPOSE: Bioabsorbable suture anchors have been popularized due to potential for osseous integration, less interference with diagnostic imaging, and ease of use. Recently, ultrasound assisted suture anchor systems have been introduced with the benefits of obtaining interdigitation with cancellous bone while maintaining a minimal footprint. In a cadaveric study, ultrasound assisted suture anchors demonstrated a similar pullout strength and less system displacement when compared to a benchmark bioabsorbable anchor system. However, the failure and complication rates of ultrasound assisted bioabsorbable anchors has never been demonstrated in a clinical setting. We studied the Stryker SonicAnchor by examining complication rates in foot and ankle procedures and secondarily determined the efficacy by evaluating clinical outcomes of surgeries using this anchor system. METHODS: A retrospective analysis was performed on all patients treated by the primary investigator using the Stryker SutureAnchor between the dates of May 2016 and February 2018. We included all patients for which the anchor was used during surgery with at least 2 year followup including VAS and FAOS scores. We recorded baseline demographic information as well as the type of surgery patients underwent. We recorded all intraoperative and postoperative complications for these surgeries. In addition, we compared preoperative and postoperative clinical scores. RESULTS: 57 patients met inclusion criteria. On average, patients were 53 years old at the time of surgery. Mean followup was 32.8 months. Mean BMI was 30.36. Three patients reported current tobacco use (5.3%), four patients (7.0%) had type II diabetes mellitus at the time of their surgery, and only one patient (1.8%) had osteoporosis. Common procedures were Achilles repair including Haglund’s resection, peroneal surgery, and lateral ligament reconstruction. There were two deep infections requiring reoperation, one medial malleolus stress fracture following total ankle replacement, one metatarsal stress fracture not involving the surgery site, and one DVT. No reports of anchor pullout or soft tissue repair failure. VAS and FAOS scores improved from 6.2 to 1.2 and 54.3 to 93.9. CONCLUSION: In our review of 57 patients operated on with the SonicAnchor with at least two year followup, there were zero cases of complications stemming from the anchor including anchor pullout or soft tissue repair failure. Overall, patients improved tremendously in their clinical outcome scores across a wide range of different procedures. Previous studies have demonstrated the biomechanical strength of the SonicAnchor and our review supports its clinical safety and efficacy in long-term clinical followup. SAGE Publications 2021-03-05 /pmc/articles/PMC8723164/ http://dx.doi.org/10.1177/2473011420S00164 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Article Chen, Jie Sharma, Akhil Akoh, Craig C. Kadakia, Rishin J. Parekh, Selene G. Clinical Safety and Outcomes of a Novel Ultrasound Assisted Bioabsorbable Suture Anchor in Foot and Ankle Surgeries |
title | Clinical Safety and Outcomes of a Novel Ultrasound Assisted
Bioabsorbable Suture Anchor in Foot and Ankle Surgeries |
title_full | Clinical Safety and Outcomes of a Novel Ultrasound Assisted
Bioabsorbable Suture Anchor in Foot and Ankle Surgeries |
title_fullStr | Clinical Safety and Outcomes of a Novel Ultrasound Assisted
Bioabsorbable Suture Anchor in Foot and Ankle Surgeries |
title_full_unstemmed | Clinical Safety and Outcomes of a Novel Ultrasound Assisted
Bioabsorbable Suture Anchor in Foot and Ankle Surgeries |
title_short | Clinical Safety and Outcomes of a Novel Ultrasound Assisted
Bioabsorbable Suture Anchor in Foot and Ankle Surgeries |
title_sort | clinical safety and outcomes of a novel ultrasound assisted
bioabsorbable suture anchor in foot and ankle surgeries |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8723164/ http://dx.doi.org/10.1177/2473011420S00164 |
work_keys_str_mv | AT chenjie clinicalsafetyandoutcomesofanovelultrasoundassistedbioabsorbablesutureanchorinfootandanklesurgeries AT sharmaakhil clinicalsafetyandoutcomesofanovelultrasoundassistedbioabsorbablesutureanchorinfootandanklesurgeries AT akohcraigc clinicalsafetyandoutcomesofanovelultrasoundassistedbioabsorbablesutureanchorinfootandanklesurgeries AT kadakiarishinj clinicalsafetyandoutcomesofanovelultrasoundassistedbioabsorbablesutureanchorinfootandanklesurgeries AT parekhseleneg clinicalsafetyandoutcomesofanovelultrasoundassistedbioabsorbablesutureanchorinfootandanklesurgeries |