High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging

Background/Aim: The turbo spin-echo (TSE) sequence is widely used for musculoskeletal (MSK) imaging; however, its acquisition speed is limited and can be easily affected by motion artifacts. We aimed to evaluate whether the use of a simultaneous multi-slice TSE (SMS-TSE) sequence can accelerate MSK...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Feifei, Wen, Zejun, Dou, Shewei, Kan, Xiaojing, Wei, Shufang, Ge, Yinghui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8724040/
https://www.ncbi.nlm.nih.gov/pubmed/34992546
http://dx.doi.org/10.3389/fphys.2021.759888
_version_ 1784625839988539392
author Gao, Feifei
Wen, Zejun
Dou, Shewei
Kan, Xiaojing
Wei, Shufang
Ge, Yinghui
author_facet Gao, Feifei
Wen, Zejun
Dou, Shewei
Kan, Xiaojing
Wei, Shufang
Ge, Yinghui
author_sort Gao, Feifei
collection PubMed
description Background/Aim: The turbo spin-echo (TSE) sequence is widely used for musculoskeletal (MSK) imaging; however, its acquisition speed is limited and can be easily affected by motion artifacts. We aimed to evaluate whether the use of a simultaneous multi-slice TSE (SMS-TSE) sequence can accelerate MSK imaging while maintaining image quality when compared with the routine TSE sequence. Methods: We prospectively enrolled 71 patients [mean age, 37.43 ± 12.56 (range, 20–67) years], including 37 men and 34 women, to undergo TSE and SMS sequences. The total scanning times for the wrist, ankle and knee joint with routine sequence were 14.92, 13.97, and 13.48 min, respectively. For the SMS-TSE sequence, they were 7.52, 7.20, and 6.87 min. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), were measured. Three experienced MSK imaging radiologists qualitatively evaluated the image quality of bone texture, cartilage, tendons, ligament, meniscus, and artifact using a 5-point evaluation system, and the diagnostic performance of the SMS-TSE sequences was evaluated. Results: Compared with the routine TSE sequences, the scanning time was lower by 49.60, 48.46, and 49.04% using SMS-TSE sequences for the wrist, ankle, and knee joints, respectively. For the SNR comparison, the SMS-TSE sequences were significantly higher than the routine TSE sequence for wrist (except for Axial-T2WI-FS), ankle, and knee joint MR imaging (all p < 0.05), but no statistical significance was obtained for the CNR measurement (all p > 0.05, except for Sag-PDWI-FS in ankle joint). For the wrist joint, the diagnostic sensitivity, specificity, and accuracy were 88.24, 100, and 92%. For the ankle joint, they were 100, 75, and 93.33%. For the knee joint, they were 87.50, 85.71, and 87.10%. Conclusion: The use of the SMS-TSE sequence in the wrist, ankle, and knee joints can significantly reduce the scanning time and show similar image quality when compared with the routine TSE sequence.
format Online
Article
Text
id pubmed-8724040
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87240402022-01-05 High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging Gao, Feifei Wen, Zejun Dou, Shewei Kan, Xiaojing Wei, Shufang Ge, Yinghui Front Physiol Physiology Background/Aim: The turbo spin-echo (TSE) sequence is widely used for musculoskeletal (MSK) imaging; however, its acquisition speed is limited and can be easily affected by motion artifacts. We aimed to evaluate whether the use of a simultaneous multi-slice TSE (SMS-TSE) sequence can accelerate MSK imaging while maintaining image quality when compared with the routine TSE sequence. Methods: We prospectively enrolled 71 patients [mean age, 37.43 ± 12.56 (range, 20–67) years], including 37 men and 34 women, to undergo TSE and SMS sequences. The total scanning times for the wrist, ankle and knee joint with routine sequence were 14.92, 13.97, and 13.48 min, respectively. For the SMS-TSE sequence, they were 7.52, 7.20, and 6.87 min. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), were measured. Three experienced MSK imaging radiologists qualitatively evaluated the image quality of bone texture, cartilage, tendons, ligament, meniscus, and artifact using a 5-point evaluation system, and the diagnostic performance of the SMS-TSE sequences was evaluated. Results: Compared with the routine TSE sequences, the scanning time was lower by 49.60, 48.46, and 49.04% using SMS-TSE sequences for the wrist, ankle, and knee joints, respectively. For the SNR comparison, the SMS-TSE sequences were significantly higher than the routine TSE sequence for wrist (except for Axial-T2WI-FS), ankle, and knee joint MR imaging (all p < 0.05), but no statistical significance was obtained for the CNR measurement (all p > 0.05, except for Sag-PDWI-FS in ankle joint). For the wrist joint, the diagnostic sensitivity, specificity, and accuracy were 88.24, 100, and 92%. For the ankle joint, they were 100, 75, and 93.33%. For the knee joint, they were 87.50, 85.71, and 87.10%. Conclusion: The use of the SMS-TSE sequence in the wrist, ankle, and knee joints can significantly reduce the scanning time and show similar image quality when compared with the routine TSE sequence. Frontiers Media S.A. 2021-12-21 /pmc/articles/PMC8724040/ /pubmed/34992546 http://dx.doi.org/10.3389/fphys.2021.759888 Text en Copyright © 2021 Gao, Wen, Dou, Kan, Wei and Ge. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Gao, Feifei
Wen, Zejun
Dou, Shewei
Kan, Xiaojing
Wei, Shufang
Ge, Yinghui
High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging
title High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging
title_full High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging
title_fullStr High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging
title_full_unstemmed High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging
title_short High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging
title_sort high-resolution simultaneous multi-slice accelerated turbo spin-echo musculoskeletal imaging: a head-to-head comparison with routine turbo spin-echo imaging
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8724040/
https://www.ncbi.nlm.nih.gov/pubmed/34992546
http://dx.doi.org/10.3389/fphys.2021.759888
work_keys_str_mv AT gaofeifei highresolutionsimultaneousmultisliceacceleratedturbospinechomusculoskeletalimagingaheadtoheadcomparisonwithroutineturbospinechoimaging
AT wenzejun highresolutionsimultaneousmultisliceacceleratedturbospinechomusculoskeletalimagingaheadtoheadcomparisonwithroutineturbospinechoimaging
AT doushewei highresolutionsimultaneousmultisliceacceleratedturbospinechomusculoskeletalimagingaheadtoheadcomparisonwithroutineturbospinechoimaging
AT kanxiaojing highresolutionsimultaneousmultisliceacceleratedturbospinechomusculoskeletalimagingaheadtoheadcomparisonwithroutineturbospinechoimaging
AT weishufang highresolutionsimultaneousmultisliceacceleratedturbospinechomusculoskeletalimagingaheadtoheadcomparisonwithroutineturbospinechoimaging
AT geyinghui highresolutionsimultaneousmultisliceacceleratedturbospinechomusculoskeletalimagingaheadtoheadcomparisonwithroutineturbospinechoimaging