Cargando…

Static CT myocardial perfusion imaging: image quality, artifacts including distribution and diagnostic performance compared to (82)Rb PET

BACKGROUND: Rubidium-82 positron emission tomography ((82)Rb PET) MPI is considered a noninvasive reference standard for the assessment of myocardial perfusion in coronary artery disease (CAD) patients. Our main goal was to compare the diagnostic performance of static rest/ vasodilator stress CT myo...

Descripción completa

Detalles Bibliográficos
Autores principales: Inácio, João R., Srinivasan, Sriraag Balaji, Ruddy, Terrence D., deKemp, Robert A., Rybicki, Frank, Beanlands, Rob S., Chow, Benjamin J. W., Dwivedi, Girish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8724508/
https://www.ncbi.nlm.nih.gov/pubmed/34981241
http://dx.doi.org/10.1186/s41824-021-00118-x
Descripción
Sumario:BACKGROUND: Rubidium-82 positron emission tomography ((82)Rb PET) MPI is considered a noninvasive reference standard for the assessment of myocardial perfusion in coronary artery disease (CAD) patients. Our main goal was to compare the diagnostic performance of static rest/ vasodilator stress CT myocardial perfusion imaging (CT-MPI) to stress/ rest (82)Rb PET-MPI for the identification of myocardial ischemia. METHODS: Forty-four patients with suspected or diagnosed CAD underwent both static CT-MPI and (82)Rb PET-MPI at rest and during pharmacological stress. The extent and severity of perfusion defects on PET-MPI were assessed to obtain summed stress score, summed rest score, and summed difference score. The extent and severity of perfusion defects on CT-MPI was visually assessed using the same grading scale. CT-MPI was compared with PET-MPI as the gold standard on a per-territory and a per-patient basis. RESULTS: On a per-patient basis, there was moderate agreement between CT-MPI and PET-MPI with a weighted 0.49 for detection of stress induced perfusion abnormalities. Using PET-MPI as a reference, static CT-MPI had 89% sensitivity (SS), 58% specificity (SP), 71% accuracy (AC), 88% negative predictive value (NPV), and 59% positive predictive value (PPV) to diagnose stress-rest perfusion deficits on a per-patient basis. On a per-territory analysis, CT-MPI had 73% SS, 65% SP, 67% AC, 90.8% NPV, and 34% PPV to diagnose perfusion deficits. CONCLUSIONS: CT-MPI has high sensitivity and good overall accuracy for the diagnosis of functionally significant CAD using (82)Rb PET-MPI as the reference standard. CT-MPI may play an important role in assessing the functional significance of CAD especially in combination with CCTA.