Cargando…
Correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study
BACKGROUND: Knee replacement is a very effective and indispensable treatment option for end-stage knee arthritis, and the number of cases has been increasing worldwide. A replaced knee joint without patient joint awareness is thought to be the ultimate goal of artificial knees. Joint awareness repor...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8725250/ https://www.ncbi.nlm.nih.gov/pubmed/34980073 http://dx.doi.org/10.1186/s12891-021-04971-6 |
_version_ | 1784626076002025472 |
---|---|
author | Itoh, Masafumi Itou, Junya Kuwashima, Umito Okazaki, Ken |
author_facet | Itoh, Masafumi Itou, Junya Kuwashima, Umito Okazaki, Ken |
author_sort | Itoh, Masafumi |
collection | PubMed |
description | BACKGROUND: Knee replacement is a very effective and indispensable treatment option for end-stage knee arthritis, and the number of cases has been increasing worldwide. A replaced knee joint without patient joint awareness is thought to be the ultimate goal of artificial knees. Joint awareness reportedly correlates with patient satisfaction. Although numbness around a replaced knee is a minor but common problem, its effect on postoperative outcome is controversial. Joint awareness also is sensitive to subtle abnormalities of the joint, so it must be negatively affected by numbness. Although numbness is minor, it cannot be ignored to further improve knee replacement outcomes. This study investigated the relationship between patient-reported numbness and other patient-reported outcome measures (PROMs), including joint awareness, and kneeling. We developed a numbness score based on a 5-point Likert scale on frequency of numbness, with an intraclass correlation coefficient of 0.76 and higher scores indicating less numbness. METHODS: The numbness score, New Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS), Forgotten Joint Score-12 (FJS-12), and other clinical and radiological data from 311 patients (394 primary knee replacements) were analyzed. Kneeling ability was evaluated by using kneeling-specific items in the KSS (KSS-Kneeling). RESULTS: No numbness was found in 170 knees (43.1%), and some degree of numbness was found in the remaining 224 knees (56.9%). The numbness score showed weak-to-moderate correlations with KSS-Symptoms (r = 0.44), KSS-Satisfaction (r = 0.41), KSS-Activities (r = 0.29), and all KOOS subscales (r = 0.23–0.44), and FJS-12 (r = 0.42). Multiple regression analyses suggested that midline incision positively affected the numbness score over the anteromedial incision (p = 0.04) and that a better numbness score (p = 0.001), male sex (p < 0.0001), and better postoperative knee flexion angle (0.04) positively affected kneeling. CONCLUSIONS: The numbness score positively correlated with PROMs and positively affected kneeling. Knee replacements performed via an anteromedial incision may be at higher risk for numbness. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-021-04971-6. |
format | Online Article Text |
id | pubmed-8725250 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-87252502022-01-06 Correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study Itoh, Masafumi Itou, Junya Kuwashima, Umito Okazaki, Ken BMC Musculoskelet Disord Research BACKGROUND: Knee replacement is a very effective and indispensable treatment option for end-stage knee arthritis, and the number of cases has been increasing worldwide. A replaced knee joint without patient joint awareness is thought to be the ultimate goal of artificial knees. Joint awareness reportedly correlates with patient satisfaction. Although numbness around a replaced knee is a minor but common problem, its effect on postoperative outcome is controversial. Joint awareness also is sensitive to subtle abnormalities of the joint, so it must be negatively affected by numbness. Although numbness is minor, it cannot be ignored to further improve knee replacement outcomes. This study investigated the relationship between patient-reported numbness and other patient-reported outcome measures (PROMs), including joint awareness, and kneeling. We developed a numbness score based on a 5-point Likert scale on frequency of numbness, with an intraclass correlation coefficient of 0.76 and higher scores indicating less numbness. METHODS: The numbness score, New Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS), Forgotten Joint Score-12 (FJS-12), and other clinical and radiological data from 311 patients (394 primary knee replacements) were analyzed. Kneeling ability was evaluated by using kneeling-specific items in the KSS (KSS-Kneeling). RESULTS: No numbness was found in 170 knees (43.1%), and some degree of numbness was found in the remaining 224 knees (56.9%). The numbness score showed weak-to-moderate correlations with KSS-Symptoms (r = 0.44), KSS-Satisfaction (r = 0.41), KSS-Activities (r = 0.29), and all KOOS subscales (r = 0.23–0.44), and FJS-12 (r = 0.42). Multiple regression analyses suggested that midline incision positively affected the numbness score over the anteromedial incision (p = 0.04) and that a better numbness score (p = 0.001), male sex (p < 0.0001), and better postoperative knee flexion angle (0.04) positively affected kneeling. CONCLUSIONS: The numbness score positively correlated with PROMs and positively affected kneeling. Knee replacements performed via an anteromedial incision may be at higher risk for numbness. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-021-04971-6. BioMed Central 2022-01-03 /pmc/articles/PMC8725250/ /pubmed/34980073 http://dx.doi.org/10.1186/s12891-021-04971-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Itoh, Masafumi Itou, Junya Kuwashima, Umito Okazaki, Ken Correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study |
title | Correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study |
title_full | Correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study |
title_fullStr | Correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study |
title_full_unstemmed | Correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study |
title_short | Correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study |
title_sort | correlation of patient-reported numbness around surgical scars with patient-reported outcome measures and joint awareness after knee replacement: a cohort study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8725250/ https://www.ncbi.nlm.nih.gov/pubmed/34980073 http://dx.doi.org/10.1186/s12891-021-04971-6 |
work_keys_str_mv | AT itohmasafumi correlationofpatientreportednumbnessaroundsurgicalscarswithpatientreportedoutcomemeasuresandjointawarenessafterkneereplacementacohortstudy AT itoujunya correlationofpatientreportednumbnessaroundsurgicalscarswithpatientreportedoutcomemeasuresandjointawarenessafterkneereplacementacohortstudy AT kuwashimaumito correlationofpatientreportednumbnessaroundsurgicalscarswithpatientreportedoutcomemeasuresandjointawarenessafterkneereplacementacohortstudy AT okazakiken correlationofpatientreportednumbnessaroundsurgicalscarswithpatientreportedoutcomemeasuresandjointawarenessafterkneereplacementacohortstudy |