Cargando…

Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study

INTRODUCTION: The volar locking plate has been widely used for unstable distal radius fractures to provide early recovery of wrist function. Volar plate prominence to the watershed line has been reported to be related to flexor tendon irritation, and avoid implant prominence in this area was suggest...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Yin-Ming, Chen, Chun-Yu, Lin, Kai-Cheng, Tarng, Yih-Wen, Liao, Ching-Yi, Chang, Wei-Ning
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8725281/
https://www.ncbi.nlm.nih.gov/pubmed/34980102
http://dx.doi.org/10.1186/s12891-021-04984-1
_version_ 1784626082533605376
author Huang, Yin-Ming
Chen, Chun-Yu
Lin, Kai-Cheng
Tarng, Yih-Wen
Liao, Ching-Yi
Chang, Wei-Ning
author_facet Huang, Yin-Ming
Chen, Chun-Yu
Lin, Kai-Cheng
Tarng, Yih-Wen
Liao, Ching-Yi
Chang, Wei-Ning
author_sort Huang, Yin-Ming
collection PubMed
description INTRODUCTION: The volar locking plate has been widely used for unstable distal radius fractures to provide early recovery of wrist function. Volar plate prominence to the watershed line has been reported to be related to flexor tendon irritation, and avoid implant prominence in this area was suggested. On the other hand, marginal distal radius fracture patterns required the plate to cross the watershed line, making conflict over plate positioning on marginal distal radius fractures. This study compared functional outcomes in patients with marginal distal radius fractures treated with two different implants. MATERIALS AND METHODS: A retrospective study was conducted, all patients who received a Synthes 2.4 mm LCP or an Acumed Acu-Loc VLP between January 2015 and December 2018 were reviewed. The marginal distal radius fracture pattern was the most distal horizontal fracture line within 10 mm of the lunate fossa’s joint line. The primary outcomes including patient-reported pain scores, range of motion, and grip strength were assessed. Secondary outcomes included patient-based subjective satisfaction scores of the injured wrist and hand function. The Mayo Wrist Score and the requirement for a secondary procedure related to hardware complications were also recorded. RESULTS: Forty-two patients met our inclusion criteria. Twenty-one patients were treated with the Synthes 2.4 mm LCP, and 21 patients with the Acumed Acu-Loc VLP. The primary outcome revealed that post-operative range of motion (P = 0.016) and grip strengths (P = 0.014) were significantly improved in the Acu-Loc VLP group. The MAYO wrist score in the Acu-Loc VLP group was also significantly better (P = 0.006). CONCLUSIONS: Despite advances in implant designs, flexor tendon irritation or rupture is still a complication following distal radius’s volar plating. We believe the Acumed Acu-Loc VLP design provided better functional outcomes than the Synthes 2.4 mm LCP if appropriately and carefully placed into its designed-for position. This positioning results in promising patient satisfaction when treating marginal distal radius fractures.
format Online
Article
Text
id pubmed-8725281
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-87252812022-01-06 Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study Huang, Yin-Ming Chen, Chun-Yu Lin, Kai-Cheng Tarng, Yih-Wen Liao, Ching-Yi Chang, Wei-Ning BMC Musculoskelet Disord Research INTRODUCTION: The volar locking plate has been widely used for unstable distal radius fractures to provide early recovery of wrist function. Volar plate prominence to the watershed line has been reported to be related to flexor tendon irritation, and avoid implant prominence in this area was suggested. On the other hand, marginal distal radius fracture patterns required the plate to cross the watershed line, making conflict over plate positioning on marginal distal radius fractures. This study compared functional outcomes in patients with marginal distal radius fractures treated with two different implants. MATERIALS AND METHODS: A retrospective study was conducted, all patients who received a Synthes 2.4 mm LCP or an Acumed Acu-Loc VLP between January 2015 and December 2018 were reviewed. The marginal distal radius fracture pattern was the most distal horizontal fracture line within 10 mm of the lunate fossa’s joint line. The primary outcomes including patient-reported pain scores, range of motion, and grip strength were assessed. Secondary outcomes included patient-based subjective satisfaction scores of the injured wrist and hand function. The Mayo Wrist Score and the requirement for a secondary procedure related to hardware complications were also recorded. RESULTS: Forty-two patients met our inclusion criteria. Twenty-one patients were treated with the Synthes 2.4 mm LCP, and 21 patients with the Acumed Acu-Loc VLP. The primary outcome revealed that post-operative range of motion (P = 0.016) and grip strengths (P = 0.014) were significantly improved in the Acu-Loc VLP group. The MAYO wrist score in the Acu-Loc VLP group was also significantly better (P = 0.006). CONCLUSIONS: Despite advances in implant designs, flexor tendon irritation or rupture is still a complication following distal radius’s volar plating. We believe the Acumed Acu-Loc VLP design provided better functional outcomes than the Synthes 2.4 mm LCP if appropriately and carefully placed into its designed-for position. This positioning results in promising patient satisfaction when treating marginal distal radius fractures. BioMed Central 2022-01-03 /pmc/articles/PMC8725281/ /pubmed/34980102 http://dx.doi.org/10.1186/s12891-021-04984-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Huang, Yin-Ming
Chen, Chun-Yu
Lin, Kai-Cheng
Tarng, Yih-Wen
Liao, Ching-Yi
Chang, Wei-Ning
Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
title Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
title_full Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
title_fullStr Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
title_full_unstemmed Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
title_short Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
title_sort functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8725281/
https://www.ncbi.nlm.nih.gov/pubmed/34980102
http://dx.doi.org/10.1186/s12891-021-04984-1
work_keys_str_mv AT huangyinming functionaloutcomesfollowingfixationofamarginaldistalradiusfracturewithtwocommonlyusedvolarlockingplatesaretrospectivecohortstudy
AT chenchunyu functionaloutcomesfollowingfixationofamarginaldistalradiusfracturewithtwocommonlyusedvolarlockingplatesaretrospectivecohortstudy
AT linkaicheng functionaloutcomesfollowingfixationofamarginaldistalradiusfracturewithtwocommonlyusedvolarlockingplatesaretrospectivecohortstudy
AT tarngyihwen functionaloutcomesfollowingfixationofamarginaldistalradiusfracturewithtwocommonlyusedvolarlockingplatesaretrospectivecohortstudy
AT liaochingyi functionaloutcomesfollowingfixationofamarginaldistalradiusfracturewithtwocommonlyusedvolarlockingplatesaretrospectivecohortstudy
AT changweining functionaloutcomesfollowingfixationofamarginaldistalradiusfracturewithtwocommonlyusedvolarlockingplatesaretrospectivecohortstudy