Cargando…

Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement

BACKGROUND: Whole body standing alignment (WBSA) in terms of biomechanics can be evaluated accurately only by referring the gravity line (GL) which lies on the gravity center (GC). Here, we introduce a method for estimating GL and simultaneous WBSA measurement using the EOS® imaging system and repor...

Descripción completa

Detalles Bibliográficos
Autores principales: Hasegawa, Kazuhiro, Amabile, Celia, Nesme, Matthieu, Dubousset, Jean
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8725375/
https://www.ncbi.nlm.nih.gov/pubmed/34980054
http://dx.doi.org/10.1186/s12891-021-04948-5
_version_ 1784626103581671424
author Hasegawa, Kazuhiro
Amabile, Celia
Nesme, Matthieu
Dubousset, Jean
author_facet Hasegawa, Kazuhiro
Amabile, Celia
Nesme, Matthieu
Dubousset, Jean
author_sort Hasegawa, Kazuhiro
collection PubMed
description BACKGROUND: Whole body standing alignment (WBSA) in terms of biomechanics can be evaluated accurately only by referring the gravity line (GL) which lies on the gravity center (GC). Here, we introduce a method for estimating GL and simultaneous WBSA measurement using the EOS® imaging system and report on the reproducibility and reliability of the method. METHODS: A 3-dimensional (3D) avatar to estimate GC was created following three steps: 3D reconstruction of the bone based on EOS images; deformation into a generic morphotype (MakeHuman statistical model) before density integration with 3D rasterization of the full body into 1-mm(3) voxels (the content of each voxel is considered homogeneous); computation of the density of all the voxels provides the center of mass, which can be projected onto the floor as the GC of the full body, providing the GL in relation to the WBSA. The repeatability, reproducibility, and accuracy of the estimated GC and body weight of the avatar were compared with clinical estimation using a force plate in healthy volunteers and patients with degenerative and deformative diseases. RESULTS: Statistical analyses of the data revealed that the repeatability and reproducibility of the estimation was high with intra-rater and inter-rater intraclass correlation coefficient. ≥0.999. The coordinate values of the GC and body weight estimation did not differ significantly between the avatar and force plate measurements, demonstrating the high accuracy of the method. CONCLUSION: This new method of estimating GC and WBSA is reliable and accurate. Application of this method could allow clinicians to quickly and qualitatively evaluate WBSA with GL with various spinal malalignment pathologies.
format Online
Article
Text
id pubmed-8725375
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-87253752022-01-06 Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement Hasegawa, Kazuhiro Amabile, Celia Nesme, Matthieu Dubousset, Jean BMC Musculoskelet Disord Research Article BACKGROUND: Whole body standing alignment (WBSA) in terms of biomechanics can be evaluated accurately only by referring the gravity line (GL) which lies on the gravity center (GC). Here, we introduce a method for estimating GL and simultaneous WBSA measurement using the EOS® imaging system and report on the reproducibility and reliability of the method. METHODS: A 3-dimensional (3D) avatar to estimate GC was created following three steps: 3D reconstruction of the bone based on EOS images; deformation into a generic morphotype (MakeHuman statistical model) before density integration with 3D rasterization of the full body into 1-mm(3) voxels (the content of each voxel is considered homogeneous); computation of the density of all the voxels provides the center of mass, which can be projected onto the floor as the GC of the full body, providing the GL in relation to the WBSA. The repeatability, reproducibility, and accuracy of the estimated GC and body weight of the avatar were compared with clinical estimation using a force plate in healthy volunteers and patients with degenerative and deformative diseases. RESULTS: Statistical analyses of the data revealed that the repeatability and reproducibility of the estimation was high with intra-rater and inter-rater intraclass correlation coefficient. ≥0.999. The coordinate values of the GC and body weight estimation did not differ significantly between the avatar and force plate measurements, demonstrating the high accuracy of the method. CONCLUSION: This new method of estimating GC and WBSA is reliable and accurate. Application of this method could allow clinicians to quickly and qualitatively evaluate WBSA with GL with various spinal malalignment pathologies. BioMed Central 2022-01-03 /pmc/articles/PMC8725375/ /pubmed/34980054 http://dx.doi.org/10.1186/s12891-021-04948-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Hasegawa, Kazuhiro
Amabile, Celia
Nesme, Matthieu
Dubousset, Jean
Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement
title Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement
title_full Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement
title_fullStr Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement
title_full_unstemmed Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement
title_short Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement
title_sort gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8725375/
https://www.ncbi.nlm.nih.gov/pubmed/34980054
http://dx.doi.org/10.1186/s12891-021-04948-5
work_keys_str_mv AT hasegawakazuhiro gravitycenterestimationforevaluationofstandingwholebodycompensationusingvirtualbarycentremetrybasedonbiplanarslotscanningstereoradiographyvalidationbysimultaneousforceplatemeasurement
AT amabilecelia gravitycenterestimationforevaluationofstandingwholebodycompensationusingvirtualbarycentremetrybasedonbiplanarslotscanningstereoradiographyvalidationbysimultaneousforceplatemeasurement
AT nesmematthieu gravitycenterestimationforevaluationofstandingwholebodycompensationusingvirtualbarycentremetrybasedonbiplanarslotscanningstereoradiographyvalidationbysimultaneousforceplatemeasurement
AT duboussetjean gravitycenterestimationforevaluationofstandingwholebodycompensationusingvirtualbarycentremetrybasedonbiplanarslotscanningstereoradiographyvalidationbysimultaneousforceplatemeasurement