BACKGROUND: The aim of the study was to assess the dosimetric comparison of bone marrow between standard IMRT(SD-IMRT) and bone marrow sparing IMRT (BMS-IMRT) among carcinoma cervix patients who underwent radical or adjuvant chemoradiation in a tertiary cancer center. MATERIALS AND METHODS: Forty el...

Descripción completa

Detalles Bibliográficos
Autores principales: Pattanayak, Lucy, Mohanta, Samir, Panda, Sasmita, Mohapatra, Manoranjan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8726445/
https://www.ncbi.nlm.nih.gov/pubmed/34992871
http://dx.doi.org/10.5603/RPOR.a2021.0120
_version_ 1784626324840644608
author Pattanayak, Lucy
Mohanta, Samir
Panda, Sasmita
Mohapatra, Manoranjan
author_facet Pattanayak, Lucy
Mohanta, Samir
Panda, Sasmita
Mohapatra, Manoranjan
author_sort Pattanayak, Lucy
collection PubMed
description BACKGROUND: The aim of the study was to assess the dosimetric comparison of bone marrow between standard IMRT(SD-IMRT) and bone marrow sparing IMRT (BMS-IMRT) among carcinoma cervix patients who underwent radical or adjuvant chemoradiation in a tertiary cancer center. MATERIALS AND METHODS: Forty eligible patients of histo-pathologically proven carcinoma cervix were enrolled in the study that was randomized on a 1:1 basis between SD-IMRT and BMS-IMRT from July 2018 to October 2019. The whole pelvis, bilateral femoral heads, and upper 1/3(rd) femur were contoured using the whole bone technique as a surrogate marker for the bone marrow. In both arms, V10, V20, and V40, bone marrow was noted along with mean, maximum, minimum dose, and total volume. DVH for the bone marrow in both arms was compared using the unpaired student t-test. RESULTS: We found no significant difference in the mean of various parameters in SD-IMRT arm vs. BMS IMRT arm — for the bone marrow: V10 (89 ± 4.3% vs. 86.7 ± 3.7%), V20 (73.2 ± 5.3% vs. 73.1 ± 4.5%), V40 (23.9 ± 5.4% vs. 26.6 ± 7.4%) and, similarly, for mean dose (28.1 ± 3.5% vs. 28.1 ± 1.8%), maximum dose (53.4 ± 0.58% vs. 53.2 ± 0.58%), minimum dose (0.33 ± 0.18% vs. 0.38 ± 0.38%), total volume (961 ± 110 cc vs. 901 ± 152 cc). CONCLUSION: This study shows no statistically significant difference in dosimetry between the two groups, which suggests that SD-IMRT spares the bone marrow adequately. Therefore, the need for BMS-IMRT using the present contouring technique does not give any added advantage over SD-IMRT. However, large sample size, other novel contouring technique, and multivariate analysis are needed to reach a definite conclusion.
format Online
Article
Text
id pubmed-8726445
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-87264452022-01-05 Comparison of dosimetric data of bone marrow between standard IMRT and bone marrow sparing IMRT in carcinoma cervix Pattanayak, Lucy Mohanta, Samir Panda, Sasmita Mohapatra, Manoranjan Rep Pract Oncol Radiother Research Paper BACKGROUND: The aim of the study was to assess the dosimetric comparison of bone marrow between standard IMRT(SD-IMRT) and bone marrow sparing IMRT (BMS-IMRT) among carcinoma cervix patients who underwent radical or adjuvant chemoradiation in a tertiary cancer center. MATERIALS AND METHODS: Forty eligible patients of histo-pathologically proven carcinoma cervix were enrolled in the study that was randomized on a 1:1 basis between SD-IMRT and BMS-IMRT from July 2018 to October 2019. The whole pelvis, bilateral femoral heads, and upper 1/3(rd) femur were contoured using the whole bone technique as a surrogate marker for the bone marrow. In both arms, V10, V20, and V40, bone marrow was noted along with mean, maximum, minimum dose, and total volume. DVH for the bone marrow in both arms was compared using the unpaired student t-test. RESULTS: We found no significant difference in the mean of various parameters in SD-IMRT arm vs. BMS IMRT arm — for the bone marrow: V10 (89 ± 4.3% vs. 86.7 ± 3.7%), V20 (73.2 ± 5.3% vs. 73.1 ± 4.5%), V40 (23.9 ± 5.4% vs. 26.6 ± 7.4%) and, similarly, for mean dose (28.1 ± 3.5% vs. 28.1 ± 1.8%), maximum dose (53.4 ± 0.58% vs. 53.2 ± 0.58%), minimum dose (0.33 ± 0.18% vs. 0.38 ± 0.38%), total volume (961 ± 110 cc vs. 901 ± 152 cc). CONCLUSION: This study shows no statistically significant difference in dosimetry between the two groups, which suggests that SD-IMRT spares the bone marrow adequately. Therefore, the need for BMS-IMRT using the present contouring technique does not give any added advantage over SD-IMRT. However, large sample size, other novel contouring technique, and multivariate analysis are needed to reach a definite conclusion. Via Medica 2021-12-30 /pmc/articles/PMC8726445/ /pubmed/34992871 http://dx.doi.org/10.5603/RPOR.a2021.0120 Text en © 2021 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially
spellingShingle Research Paper
Pattanayak, Lucy
Mohanta, Samir
Panda, Sasmita
Mohapatra, Manoranjan
Comparison of dosimetric data of bone marrow between standard IMRT and bone marrow sparing IMRT in carcinoma cervix
title Comparison of dosimetric data of bone marrow between standard IMRT and bone marrow sparing IMRT in carcinoma cervix
title_full Comparison of dosimetric data of bone marrow between standard IMRT and bone marrow sparing IMRT in carcinoma cervix
title_fullStr Comparison of dosimetric data of bone marrow between standard IMRT and bone marrow sparing IMRT in carcinoma cervix
title_full_unstemmed Comparison of dosimetric data of bone marrow between standard IMRT and bone marrow sparing IMRT in carcinoma cervix
title_short Comparison of dosimetric data of bone marrow between standard IMRT and bone marrow sparing IMRT in carcinoma cervix
title_sort comparison of dosimetric data of bone marrow between standard imrt and bone marrow sparing imrt in carcinoma cervix
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8726445/
https://www.ncbi.nlm.nih.gov/pubmed/34992871
http://dx.doi.org/10.5603/RPOR.a2021.0120
work_keys_str_mv AT pattanayaklucy comparisonofdosimetricdataofbonemarrowbetweenstandardimrtandbonemarrowsparingimrtincarcinomacervix
AT mohantasamir comparisonofdosimetricdataofbonemarrowbetweenstandardimrtandbonemarrowsparingimrtincarcinomacervix
AT pandasasmita comparisonofdosimetricdataofbonemarrowbetweenstandardimrtandbonemarrowsparingimrtincarcinomacervix
AT mohapatramanoranjan comparisonofdosimetricdataofbonemarrowbetweenstandardimrtandbonemarrowsparingimrtincarcinomacervix