Cargando…

Analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer

BACKGROUND: With full access to both helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT), we compared locally advanced non-small cell lung cancer (LA-NSCLC) treatment plans and verified the plans using patient-specific pretreatment quality assurance (PSQA). MATERIALS AND METHODS: Fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Klunklin, Pitchayaponne, Manoharn, Tamisa, Wanwilairat, Somsak, Nobnop, Wannapha, Watcharawipha, Anirut, Chitapanarux, Imjai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8726455/
https://www.ncbi.nlm.nih.gov/pubmed/34992866
http://dx.doi.org/10.5603/RPOR.a2021.0113
_version_ 1784626327386587136
author Klunklin, Pitchayaponne
Manoharn, Tamisa
Wanwilairat, Somsak
Nobnop, Wannapha
Watcharawipha, Anirut
Chitapanarux, Imjai
author_facet Klunklin, Pitchayaponne
Manoharn, Tamisa
Wanwilairat, Somsak
Nobnop, Wannapha
Watcharawipha, Anirut
Chitapanarux, Imjai
author_sort Klunklin, Pitchayaponne
collection PubMed
description BACKGROUND: With full access to both helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT), we compared locally advanced non-small cell lung cancer (LA-NSCLC) treatment plans and verified the plans using patient-specific pretreatment quality assurance (PSQA). MATERIALS AND METHODS: For each of the seventeen patients included in the study, two treatment plans (i.e. HT and VMAT) were created. Optimized plans were evaluated following the ICRU 83 criteria. Planned quality indexes and dosimetric parameters were compared. Lastly, all plans were subjected to PSQA assessment by determining the gamma passing rate (GPR). RESULTS: All dosimetry results obtained from the planning target volume passed the ICRU 83 criteria. With regard to similar homogeneity indices, VMAT produced better conformity number values than HT (0.78 vs. 0.64), but differences in the values were insignificant. Furthermore, VMAT was associated with a significantly shorter mean treatment time (1.91 minutes vs. 6.66 minutes). For PSQA assessment, both techniques resulted in adequate GPR values (> 90% at the 3%/3 mm criteria). CONCLUSION: Both HT and VMAT techniques led to the generation of clinically satisfactory and reliable radiotherapy plans. However, the VMAT plan was associated with a non-significantly better degree of conformity and a significantly shorter treatment time. Thus, VMAT was determined to be a better choice for LA-NSCLC.
format Online
Article
Text
id pubmed-8726455
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-87264552022-01-05 Analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer Klunklin, Pitchayaponne Manoharn, Tamisa Wanwilairat, Somsak Nobnop, Wannapha Watcharawipha, Anirut Chitapanarux, Imjai Rep Pract Oncol Radiother Research Paper BACKGROUND: With full access to both helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT), we compared locally advanced non-small cell lung cancer (LA-NSCLC) treatment plans and verified the plans using patient-specific pretreatment quality assurance (PSQA). MATERIALS AND METHODS: For each of the seventeen patients included in the study, two treatment plans (i.e. HT and VMAT) were created. Optimized plans were evaluated following the ICRU 83 criteria. Planned quality indexes and dosimetric parameters were compared. Lastly, all plans were subjected to PSQA assessment by determining the gamma passing rate (GPR). RESULTS: All dosimetry results obtained from the planning target volume passed the ICRU 83 criteria. With regard to similar homogeneity indices, VMAT produced better conformity number values than HT (0.78 vs. 0.64), but differences in the values were insignificant. Furthermore, VMAT was associated with a significantly shorter mean treatment time (1.91 minutes vs. 6.66 minutes). For PSQA assessment, both techniques resulted in adequate GPR values (> 90% at the 3%/3 mm criteria). CONCLUSION: Both HT and VMAT techniques led to the generation of clinically satisfactory and reliable radiotherapy plans. However, the VMAT plan was associated with a non-significantly better degree of conformity and a significantly shorter treatment time. Thus, VMAT was determined to be a better choice for LA-NSCLC. Via Medica 2021-12-30 /pmc/articles/PMC8726455/ /pubmed/34992866 http://dx.doi.org/10.5603/RPOR.a2021.0113 Text en © 2021 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially
spellingShingle Research Paper
Klunklin, Pitchayaponne
Manoharn, Tamisa
Wanwilairat, Somsak
Nobnop, Wannapha
Watcharawipha, Anirut
Chitapanarux, Imjai
Analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer
title Analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer
title_full Analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer
title_fullStr Analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer
title_full_unstemmed Analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer
title_short Analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer
title_sort analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8726455/
https://www.ncbi.nlm.nih.gov/pubmed/34992866
http://dx.doi.org/10.5603/RPOR.a2021.0113
work_keys_str_mv AT klunklinpitchayaponne analysisoftheplanneddelivereddosedistributionsandqualityassuranceforhelicaltomotherapyandvolumetricmodulatedarctherapyinlocallyadvancednonsmallcelllungcancer
AT manoharntamisa analysisoftheplanneddelivereddosedistributionsandqualityassuranceforhelicaltomotherapyandvolumetricmodulatedarctherapyinlocallyadvancednonsmallcelllungcancer
AT wanwilairatsomsak analysisoftheplanneddelivereddosedistributionsandqualityassuranceforhelicaltomotherapyandvolumetricmodulatedarctherapyinlocallyadvancednonsmallcelllungcancer
AT nobnopwannapha analysisoftheplanneddelivereddosedistributionsandqualityassuranceforhelicaltomotherapyandvolumetricmodulatedarctherapyinlocallyadvancednonsmallcelllungcancer
AT watcharawiphaanirut analysisoftheplanneddelivereddosedistributionsandqualityassuranceforhelicaltomotherapyandvolumetricmodulatedarctherapyinlocallyadvancednonsmallcelllungcancer
AT chitapanaruximjai analysisoftheplanneddelivereddosedistributionsandqualityassuranceforhelicaltomotherapyandvolumetricmodulatedarctherapyinlocallyadvancednonsmallcelllungcancer