Cargando…
Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays
[Image: see text] A range of biosensing techniques including immunoassays are routinely used for quantitation of analytes in biological samples and available in a range of formats, from centralized lab testing (e.g., microplate enzyme-linked immunosorbent assay (ELISA)) to automated point-of-care (P...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2021
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8728737/ https://www.ncbi.nlm.nih.gov/pubmed/34854666 http://dx.doi.org/10.1021/acssensors.1c01524 |
_version_ | 1784626794485252096 |
---|---|
author | Reis, Nuno M. Needs, Sarah H. Jegouic, Sophie M. Gill, Kirandeep K. Sirivisoot, Sirintra Howard, Scott Kempe, Jack Bola, Shaan Al-Hakeem, Kareem Jones, Ian M. Prommool, Tanapan Luangaram, Prasit Avirutnan, Panisadee Puttikhunt, Chunya Edwards, Alexander D. |
author_facet | Reis, Nuno M. Needs, Sarah H. Jegouic, Sophie M. Gill, Kirandeep K. Sirivisoot, Sirintra Howard, Scott Kempe, Jack Bola, Shaan Al-Hakeem, Kareem Jones, Ian M. Prommool, Tanapan Luangaram, Prasit Avirutnan, Panisadee Puttikhunt, Chunya Edwards, Alexander D. |
author_sort | Reis, Nuno M. |
collection | PubMed |
description | [Image: see text] A range of biosensing techniques including immunoassays are routinely used for quantitation of analytes in biological samples and available in a range of formats, from centralized lab testing (e.g., microplate enzyme-linked immunosorbent assay (ELISA)) to automated point-of-care (POC) and lateral flow immunochromatographic tests. High analytical performance is intrinsically linked to the use of a sequence of reagent and washing steps, yet this is extremely challenging to deliver at the POC without a high level of fluidic control involving, e.g., automation, fluidic pumping, or manual fluid handling/pipetting. Here we introduce a microfluidic siphon concept that conceptualizes a multistep ″dipstick″ for quantitative, enzymatically amplified immunoassays using a strip of microporous or microbored material. We demonstrated that gravity-driven siphon flow can be realized in single-bore glass capillaries, a multibored microcapillary film, and a glass fiber porous membrane. In contrast to other POC devices proposed to date, the operation of the siphon is only dependent on the hydrostatic liquid pressure (gravity) and not capillary forces, and the unique stepwise approach to the delivery of the sample and immunoassay reagents results in zero dead volume in the device, no reagent overlap or carryover, and full start/stop fluid control. We demonstrated applications of a 10-bore microfluidic siphon as a portable ELISA system without compromised quantitative capabilities in two global diagnostic applications: (1) a four-plex sandwich ELISA for rapid smartphone dengue serotype identification by serotype-specific dengue virus NS1 antigen detection, relevant for acute dengue fever diagnosis, and (2) quantitation of anti-SARS-CoV-2 IgG and IgM titers in spiked serum samples. Diagnostic siphons provide the opportunity for high-performance immunoassay testing outside sophisticated laboratories, meeting the rapidly changing global clinical and public health needs. |
format | Online Article Text |
id | pubmed-8728737 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-87287372022-01-05 Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays Reis, Nuno M. Needs, Sarah H. Jegouic, Sophie M. Gill, Kirandeep K. Sirivisoot, Sirintra Howard, Scott Kempe, Jack Bola, Shaan Al-Hakeem, Kareem Jones, Ian M. Prommool, Tanapan Luangaram, Prasit Avirutnan, Panisadee Puttikhunt, Chunya Edwards, Alexander D. ACS Sens [Image: see text] A range of biosensing techniques including immunoassays are routinely used for quantitation of analytes in biological samples and available in a range of formats, from centralized lab testing (e.g., microplate enzyme-linked immunosorbent assay (ELISA)) to automated point-of-care (POC) and lateral flow immunochromatographic tests. High analytical performance is intrinsically linked to the use of a sequence of reagent and washing steps, yet this is extremely challenging to deliver at the POC without a high level of fluidic control involving, e.g., automation, fluidic pumping, or manual fluid handling/pipetting. Here we introduce a microfluidic siphon concept that conceptualizes a multistep ″dipstick″ for quantitative, enzymatically amplified immunoassays using a strip of microporous or microbored material. We demonstrated that gravity-driven siphon flow can be realized in single-bore glass capillaries, a multibored microcapillary film, and a glass fiber porous membrane. In contrast to other POC devices proposed to date, the operation of the siphon is only dependent on the hydrostatic liquid pressure (gravity) and not capillary forces, and the unique stepwise approach to the delivery of the sample and immunoassay reagents results in zero dead volume in the device, no reagent overlap or carryover, and full start/stop fluid control. We demonstrated applications of a 10-bore microfluidic siphon as a portable ELISA system without compromised quantitative capabilities in two global diagnostic applications: (1) a four-plex sandwich ELISA for rapid smartphone dengue serotype identification by serotype-specific dengue virus NS1 antigen detection, relevant for acute dengue fever diagnosis, and (2) quantitation of anti-SARS-CoV-2 IgG and IgM titers in spiked serum samples. Diagnostic siphons provide the opportunity for high-performance immunoassay testing outside sophisticated laboratories, meeting the rapidly changing global clinical and public health needs. American Chemical Society 2021-12-02 2021-12-24 /pmc/articles/PMC8728737/ /pubmed/34854666 http://dx.doi.org/10.1021/acssensors.1c01524 Text en © 2021 American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Reis, Nuno M. Needs, Sarah H. Jegouic, Sophie M. Gill, Kirandeep K. Sirivisoot, Sirintra Howard, Scott Kempe, Jack Bola, Shaan Al-Hakeem, Kareem Jones, Ian M. Prommool, Tanapan Luangaram, Prasit Avirutnan, Panisadee Puttikhunt, Chunya Edwards, Alexander D. Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays |
title | Gravity-Driven Microfluidic Siphons: Fluidic Characterization
and Application to Quantitative Immunoassays |
title_full | Gravity-Driven Microfluidic Siphons: Fluidic Characterization
and Application to Quantitative Immunoassays |
title_fullStr | Gravity-Driven Microfluidic Siphons: Fluidic Characterization
and Application to Quantitative Immunoassays |
title_full_unstemmed | Gravity-Driven Microfluidic Siphons: Fluidic Characterization
and Application to Quantitative Immunoassays |
title_short | Gravity-Driven Microfluidic Siphons: Fluidic Characterization
and Application to Quantitative Immunoassays |
title_sort | gravity-driven microfluidic siphons: fluidic characterization
and application to quantitative immunoassays |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8728737/ https://www.ncbi.nlm.nih.gov/pubmed/34854666 http://dx.doi.org/10.1021/acssensors.1c01524 |
work_keys_str_mv | AT reisnunom gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT needssarahh gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT jegouicsophiem gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT gillkirandeepk gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT sirivisootsirintra gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT howardscott gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT kempejack gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT bolashaan gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT alhakeemkareem gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT jonesianm gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT prommooltanapan gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT luangaramprasit gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT avirutnanpanisadee gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT puttikhuntchunya gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays AT edwardsalexanderd gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays |