Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays

[Image: see text] A range of biosensing techniques including immunoassays are routinely used for quantitation of analytes in biological samples and available in a range of formats, from centralized lab testing (e.g., microplate enzyme-linked immunosorbent assay (ELISA)) to automated point-of-care (P...

Descripción completa

Detalles Bibliográficos
Autores principales: Reis, Nuno M., Needs, Sarah H., Jegouic, Sophie M., Gill, Kirandeep K., Sirivisoot, Sirintra, Howard, Scott, Kempe, Jack, Bola, Shaan, Al-Hakeem, Kareem, Jones, Ian M., Prommool, Tanapan, Luangaram, Prasit, Avirutnan, Panisadee, Puttikhunt, Chunya, Edwards, Alexander D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8728737/
https://www.ncbi.nlm.nih.gov/pubmed/34854666
http://dx.doi.org/10.1021/acssensors.1c01524
_version_ 1784626794485252096
author Reis, Nuno M.
Needs, Sarah H.
Jegouic, Sophie M.
Gill, Kirandeep K.
Sirivisoot, Sirintra
Howard, Scott
Kempe, Jack
Bola, Shaan
Al-Hakeem, Kareem
Jones, Ian M.
Prommool, Tanapan
Luangaram, Prasit
Avirutnan, Panisadee
Puttikhunt, Chunya
Edwards, Alexander D.
author_facet Reis, Nuno M.
Needs, Sarah H.
Jegouic, Sophie M.
Gill, Kirandeep K.
Sirivisoot, Sirintra
Howard, Scott
Kempe, Jack
Bola, Shaan
Al-Hakeem, Kareem
Jones, Ian M.
Prommool, Tanapan
Luangaram, Prasit
Avirutnan, Panisadee
Puttikhunt, Chunya
Edwards, Alexander D.
author_sort Reis, Nuno M.
collection PubMed
description [Image: see text] A range of biosensing techniques including immunoassays are routinely used for quantitation of analytes in biological samples and available in a range of formats, from centralized lab testing (e.g., microplate enzyme-linked immunosorbent assay (ELISA)) to automated point-of-care (POC) and lateral flow immunochromatographic tests. High analytical performance is intrinsically linked to the use of a sequence of reagent and washing steps, yet this is extremely challenging to deliver at the POC without a high level of fluidic control involving, e.g., automation, fluidic pumping, or manual fluid handling/pipetting. Here we introduce a microfluidic siphon concept that conceptualizes a multistep ″dipstick″ for quantitative, enzymatically amplified immunoassays using a strip of microporous or microbored material. We demonstrated that gravity-driven siphon flow can be realized in single-bore glass capillaries, a multibored microcapillary film, and a glass fiber porous membrane. In contrast to other POC devices proposed to date, the operation of the siphon is only dependent on the hydrostatic liquid pressure (gravity) and not capillary forces, and the unique stepwise approach to the delivery of the sample and immunoassay reagents results in zero dead volume in the device, no reagent overlap or carryover, and full start/stop fluid control. We demonstrated applications of a 10-bore microfluidic siphon as a portable ELISA system without compromised quantitative capabilities in two global diagnostic applications: (1) a four-plex sandwich ELISA for rapid smartphone dengue serotype identification by serotype-specific dengue virus NS1 antigen detection, relevant for acute dengue fever diagnosis, and (2) quantitation of anti-SARS-CoV-2 IgG and IgM titers in spiked serum samples. Diagnostic siphons provide the opportunity for high-performance immunoassay testing outside sophisticated laboratories, meeting the rapidly changing global clinical and public health needs.
format Online
Article
Text
id pubmed-8728737
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-87287372022-01-05 Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays Reis, Nuno M. Needs, Sarah H. Jegouic, Sophie M. Gill, Kirandeep K. Sirivisoot, Sirintra Howard, Scott Kempe, Jack Bola, Shaan Al-Hakeem, Kareem Jones, Ian M. Prommool, Tanapan Luangaram, Prasit Avirutnan, Panisadee Puttikhunt, Chunya Edwards, Alexander D. ACS Sens [Image: see text] A range of biosensing techniques including immunoassays are routinely used for quantitation of analytes in biological samples and available in a range of formats, from centralized lab testing (e.g., microplate enzyme-linked immunosorbent assay (ELISA)) to automated point-of-care (POC) and lateral flow immunochromatographic tests. High analytical performance is intrinsically linked to the use of a sequence of reagent and washing steps, yet this is extremely challenging to deliver at the POC without a high level of fluidic control involving, e.g., automation, fluidic pumping, or manual fluid handling/pipetting. Here we introduce a microfluidic siphon concept that conceptualizes a multistep ″dipstick″ for quantitative, enzymatically amplified immunoassays using a strip of microporous or microbored material. We demonstrated that gravity-driven siphon flow can be realized in single-bore glass capillaries, a multibored microcapillary film, and a glass fiber porous membrane. In contrast to other POC devices proposed to date, the operation of the siphon is only dependent on the hydrostatic liquid pressure (gravity) and not capillary forces, and the unique stepwise approach to the delivery of the sample and immunoassay reagents results in zero dead volume in the device, no reagent overlap or carryover, and full start/stop fluid control. We demonstrated applications of a 10-bore microfluidic siphon as a portable ELISA system without compromised quantitative capabilities in two global diagnostic applications: (1) a four-plex sandwich ELISA for rapid smartphone dengue serotype identification by serotype-specific dengue virus NS1 antigen detection, relevant for acute dengue fever diagnosis, and (2) quantitation of anti-SARS-CoV-2 IgG and IgM titers in spiked serum samples. Diagnostic siphons provide the opportunity for high-performance immunoassay testing outside sophisticated laboratories, meeting the rapidly changing global clinical and public health needs. American Chemical Society 2021-12-02 2021-12-24 /pmc/articles/PMC8728737/ /pubmed/34854666 http://dx.doi.org/10.1021/acssensors.1c01524 Text en © 2021 American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Reis, Nuno M.
Needs, Sarah H.
Jegouic, Sophie M.
Gill, Kirandeep K.
Sirivisoot, Sirintra
Howard, Scott
Kempe, Jack
Bola, Shaan
Al-Hakeem, Kareem
Jones, Ian M.
Prommool, Tanapan
Luangaram, Prasit
Avirutnan, Panisadee
Puttikhunt, Chunya
Edwards, Alexander D.
Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays
title Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays
title_full Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays
title_fullStr Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays
title_full_unstemmed Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays
title_short Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays
title_sort gravity-driven microfluidic siphons: fluidic characterization and application to quantitative immunoassays
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8728737/
https://www.ncbi.nlm.nih.gov/pubmed/34854666
http://dx.doi.org/10.1021/acssensors.1c01524
work_keys_str_mv AT reisnunom gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT needssarahh gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT jegouicsophiem gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT gillkirandeepk gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT sirivisootsirintra gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT howardscott gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT kempejack gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT bolashaan gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT alhakeemkareem gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT jonesianm gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT prommooltanapan gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT luangaramprasit gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT avirutnanpanisadee gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT puttikhuntchunya gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays
AT edwardsalexanderd gravitydrivenmicrofluidicsiphonsfluidiccharacterizationandapplicationtoquantitativeimmunoassays