Cargando…

Intracorporeal gastrojejunostomy in Roux-en-Y reconstruction with its efferent loop located on the patient's left side following totally laparoscopic distal gastrectomy: A case report

The drawback of intracorporeal gastrojejunostomy using only endoscopic linear staplers in antecolic Roux-en-Y (R-Y) reconstruction with its efferent loop located on the patient's left side following totally laparoscopic distal gastrectomy (TLDG) is the occurrence of anastomotic failure, even th...

Descripción completa

Detalles Bibliográficos
Autores principales: Tokuhara, Takaya, Nakata, Eiji, Ogata, Akihito, Tenjo, Toshiyuki, Kawai, Isao, Kondo, Keisaku, Hatabe, Shigeru, Yokoyama, Kazutake
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8739077/
https://www.ncbi.nlm.nih.gov/pubmed/35003745
http://dx.doi.org/10.3892/mco.2021.2480
Descripción
Sumario:The drawback of intracorporeal gastrojejunostomy using only endoscopic linear staplers in antecolic Roux-en-Y (R-Y) reconstruction with its efferent loop located on the patient's left side following totally laparoscopic distal gastrectomy (TLDG) is the occurrence of anastomotic failure, even though this reconstruction system is assumed to prevent intraoperative and postoperative twisting of the gastrojejunostomy and lifted jejunum. This case report presents two patients with gastric cancer who underwent intracorporeal gastrojejunostomy consisting of linear stapling and hand suturing in antecolic R-Y reconstruction with its efferent loop located on the patient's left side following TLDG to prevent anastomotic failure of the gastrojejunostomy. After the sacrificed jejunum was created, linear stapling of the greater curvature of the remnant stomach and the lifted jejunum without dividing the jejunum was performed. After removing the sacrificed jejunum and creating a good view of the posterior side of the stapler entry hole, the stapler entry hole was closed from the posterior side to the anterior side, using a single-layer full-thickness and serosubmucosal hand suturing technique with knotted sutures and a knotless barbed suture. No anastomotic failure of the gastrojejunostomy occurred in either patient. Intracorporeal gastrojejunostomy consisting of linear stapling and hand suturing could be an option for gastrojejunostomy in antecolic R-Y reconstruction with its efferent loop located on the patient's left side following TLDG because it can aid in the prevention of anastomotic failure.