Cargando…
Parametric estimation of gyrotactic microorganism hybrid nanofluid flow between the conical gap of spinning disk-cone apparatus
The silver, magnesium oxide and gyrotactic microorganism-based hybrid nanofluid flow inside the conical space between disc and cone is addressed in the perspective of thermal energy stabilization. Different cases have been discussed between the spinning of cone and disc in the same or counter wise d...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8741995/ https://www.ncbi.nlm.nih.gov/pubmed/34996921 http://dx.doi.org/10.1038/s41598-021-03077-2 |
_version_ | 1784629615321415680 |
---|---|
author | Alrabaiah, Hussam Bilal, Muhammad Khan, Muhammad Altaf Muhammad, Taseer Legas, Endris Yimer |
author_facet | Alrabaiah, Hussam Bilal, Muhammad Khan, Muhammad Altaf Muhammad, Taseer Legas, Endris Yimer |
author_sort | Alrabaiah, Hussam |
collection | PubMed |
description | The silver, magnesium oxide and gyrotactic microorganism-based hybrid nanofluid flow inside the conical space between disc and cone is addressed in the perspective of thermal energy stabilization. Different cases have been discussed between the spinning of cone and disc in the same or counter wise directions. The hybrid nanofluid has been synthesized in the presence of silver Ag and magnesium oxide MgO nanoparticulate. The viscous dissipation and the magnetic field factors are introduced to the modeled equations. The parametric continuation method (PCM) is utilized to numerically handle the modeled problem. Magnesium oxide is chemically made up of Mg(2+) and O(2-) ions that are bound by a strong ionic connection and can be made by pyrolyzing Mg(OH)(2) (magnesium hydroxide) and MgCO(3) (magnesium carbonate) at high temperature (700–1500 °C). For metallurgical, biomedical and electrical implementations, it is more efficient. Similarly, silver nanoparticle's antibacterial properties could be employed to control bacterial growth. It has been observed that a circulating disc with a stationary cone can achieve the optimum cooling of the cone-disk apparatus while the outer edge temperature remains fixed. The thermal energy profile remarkably upgraded with the magnetic effect, the addition of nanoparticulate in base fluid and Eckert number. |
format | Online Article Text |
id | pubmed-8741995 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-87419952022-01-10 Parametric estimation of gyrotactic microorganism hybrid nanofluid flow between the conical gap of spinning disk-cone apparatus Alrabaiah, Hussam Bilal, Muhammad Khan, Muhammad Altaf Muhammad, Taseer Legas, Endris Yimer Sci Rep Article The silver, magnesium oxide and gyrotactic microorganism-based hybrid nanofluid flow inside the conical space between disc and cone is addressed in the perspective of thermal energy stabilization. Different cases have been discussed between the spinning of cone and disc in the same or counter wise directions. The hybrid nanofluid has been synthesized in the presence of silver Ag and magnesium oxide MgO nanoparticulate. The viscous dissipation and the magnetic field factors are introduced to the modeled equations. The parametric continuation method (PCM) is utilized to numerically handle the modeled problem. Magnesium oxide is chemically made up of Mg(2+) and O(2-) ions that are bound by a strong ionic connection and can be made by pyrolyzing Mg(OH)(2) (magnesium hydroxide) and MgCO(3) (magnesium carbonate) at high temperature (700–1500 °C). For metallurgical, biomedical and electrical implementations, it is more efficient. Similarly, silver nanoparticle's antibacterial properties could be employed to control bacterial growth. It has been observed that a circulating disc with a stationary cone can achieve the optimum cooling of the cone-disk apparatus while the outer edge temperature remains fixed. The thermal energy profile remarkably upgraded with the magnetic effect, the addition of nanoparticulate in base fluid and Eckert number. Nature Publishing Group UK 2022-01-07 /pmc/articles/PMC8741995/ /pubmed/34996921 http://dx.doi.org/10.1038/s41598-021-03077-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Alrabaiah, Hussam Bilal, Muhammad Khan, Muhammad Altaf Muhammad, Taseer Legas, Endris Yimer Parametric estimation of gyrotactic microorganism hybrid nanofluid flow between the conical gap of spinning disk-cone apparatus |
title | Parametric estimation of gyrotactic microorganism hybrid nanofluid flow between the conical gap of spinning disk-cone apparatus |
title_full | Parametric estimation of gyrotactic microorganism hybrid nanofluid flow between the conical gap of spinning disk-cone apparatus |
title_fullStr | Parametric estimation of gyrotactic microorganism hybrid nanofluid flow between the conical gap of spinning disk-cone apparatus |
title_full_unstemmed | Parametric estimation of gyrotactic microorganism hybrid nanofluid flow between the conical gap of spinning disk-cone apparatus |
title_short | Parametric estimation of gyrotactic microorganism hybrid nanofluid flow between the conical gap of spinning disk-cone apparatus |
title_sort | parametric estimation of gyrotactic microorganism hybrid nanofluid flow between the conical gap of spinning disk-cone apparatus |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8741995/ https://www.ncbi.nlm.nih.gov/pubmed/34996921 http://dx.doi.org/10.1038/s41598-021-03077-2 |
work_keys_str_mv | AT alrabaiahhussam parametricestimationofgyrotacticmicroorganismhybridnanofluidflowbetweentheconicalgapofspinningdiskconeapparatus AT bilalmuhammad parametricestimationofgyrotacticmicroorganismhybridnanofluidflowbetweentheconicalgapofspinningdiskconeapparatus AT khanmuhammadaltaf parametricestimationofgyrotacticmicroorganismhybridnanofluidflowbetweentheconicalgapofspinningdiskconeapparatus AT muhammadtaseer parametricestimationofgyrotacticmicroorganismhybridnanofluidflowbetweentheconicalgapofspinningdiskconeapparatus AT legasendrisyimer parametricestimationofgyrotacticmicroorganismhybridnanofluidflowbetweentheconicalgapofspinningdiskconeapparatus |