Can Real-time Computer-Aided Detection Systems Diminish the Risk of Postcolonoscopy Colorectal Cancer?

The adenoma detection rate is the constant subject of research and the main marker of quality in bowel cancer screening. However, by improving the quality of endoscopy via artificial intelligence methods, all polyps, including those with the potential for malignancy, can be removed, thereby reducing...

Descripción completa

Detalles Bibliográficos
Autores principales: Madalinski, Mariusz, Prudham, Roger
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8742204/
https://www.ncbi.nlm.nih.gov/pubmed/34571490
http://dx.doi.org/10.2196/25328
_version_ 1784629668473733120
author Madalinski, Mariusz
Prudham, Roger
author_facet Madalinski, Mariusz
Prudham, Roger
author_sort Madalinski, Mariusz
collection PubMed
description The adenoma detection rate is the constant subject of research and the main marker of quality in bowel cancer screening. However, by improving the quality of endoscopy via artificial intelligence methods, all polyps, including those with the potential for malignancy, can be removed, thereby reducing interval colorectal cancer rates. As such, the removal of all polyps may become the best marker of endoscopy quality. Thus, we present a viewpoint on integrating the computer-aided detection (CADe) of polyps with high-accuracy, real-time colonoscopy to challenge quality improvements in the performance of colonoscopy. Colonoscopy for bowel cancer screening involving the integration of a deep learning methodology (ie, integrating artificial intelligence with CADe systems) has been assessed in an effort to increase the adenoma detection rate. In this viewpoint, a few studies are described, and their results show that CADe systems are able to increase screening sensitivity. The detection of adenomatous polyps, which are associated with a potential risk of progression to colorectal cancer, and their removal are expected to reduce cancer incidence and mortality rates. However, so far, artificial intelligence methods do not increase the detection of cancer or large adenomatous polyps but contribute to the detection of small precancerous polyps.
format Online
Article
Text
id pubmed-8742204
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-87422042022-01-21 Can Real-time Computer-Aided Detection Systems Diminish the Risk of Postcolonoscopy Colorectal Cancer? Madalinski, Mariusz Prudham, Roger JMIR Med Inform Viewpoint The adenoma detection rate is the constant subject of research and the main marker of quality in bowel cancer screening. However, by improving the quality of endoscopy via artificial intelligence methods, all polyps, including those with the potential for malignancy, can be removed, thereby reducing interval colorectal cancer rates. As such, the removal of all polyps may become the best marker of endoscopy quality. Thus, we present a viewpoint on integrating the computer-aided detection (CADe) of polyps with high-accuracy, real-time colonoscopy to challenge quality improvements in the performance of colonoscopy. Colonoscopy for bowel cancer screening involving the integration of a deep learning methodology (ie, integrating artificial intelligence with CADe systems) has been assessed in an effort to increase the adenoma detection rate. In this viewpoint, a few studies are described, and their results show that CADe systems are able to increase screening sensitivity. The detection of adenomatous polyps, which are associated with a potential risk of progression to colorectal cancer, and their removal are expected to reduce cancer incidence and mortality rates. However, so far, artificial intelligence methods do not increase the detection of cancer or large adenomatous polyps but contribute to the detection of small precancerous polyps. JMIR Publications 2021-12-24 /pmc/articles/PMC8742204/ /pubmed/34571490 http://dx.doi.org/10.2196/25328 Text en ©Mariusz Madalinski, Roger Prudham. Originally published in JMIR Medical Informatics (https://medinform.jmir.org), 24.12.2021. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Medical Informatics, is properly cited. The complete bibliographic information, a link to the original publication on https://medinform.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Viewpoint
Madalinski, Mariusz
Prudham, Roger
Can Real-time Computer-Aided Detection Systems Diminish the Risk of Postcolonoscopy Colorectal Cancer?
title Can Real-time Computer-Aided Detection Systems Diminish the Risk of Postcolonoscopy Colorectal Cancer?
title_full Can Real-time Computer-Aided Detection Systems Diminish the Risk of Postcolonoscopy Colorectal Cancer?
title_fullStr Can Real-time Computer-Aided Detection Systems Diminish the Risk of Postcolonoscopy Colorectal Cancer?
title_full_unstemmed Can Real-time Computer-Aided Detection Systems Diminish the Risk of Postcolonoscopy Colorectal Cancer?
title_short Can Real-time Computer-Aided Detection Systems Diminish the Risk of Postcolonoscopy Colorectal Cancer?
title_sort can real-time computer-aided detection systems diminish the risk of postcolonoscopy colorectal cancer?
topic Viewpoint
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8742204/
https://www.ncbi.nlm.nih.gov/pubmed/34571490
http://dx.doi.org/10.2196/25328
work_keys_str_mv AT madalinskimariusz canrealtimecomputeraideddetectionsystemsdiminishtheriskofpostcolonoscopycolorectalcancer
AT prudhamroger canrealtimecomputeraideddetectionsystemsdiminishtheriskofpostcolonoscopycolorectalcancer