Cargando…

Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila

BACKGROUND: Legionella pneumophila is an opportunistic waterborne pathogen of significant public health problems, which can cause serious human respiratory diseases (Legionnaires’ disease). Multiple cross displacement amplification (MCDA), a isothermal nucleic acid amplification technique, has been...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Luxi, Gu, Rumeng, Li, Xiaomeng, Song, Meijun, Huang, Xiaojun, Mu, Deguang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8742375/
https://www.ncbi.nlm.nih.gov/pubmed/34996350
http://dx.doi.org/10.1186/s12866-021-02363-3
_version_ 1784629698996731904
author Jiang, Luxi
Gu, Rumeng
Li, Xiaomeng
Song, Meijun
Huang, Xiaojun
Mu, Deguang
author_facet Jiang, Luxi
Gu, Rumeng
Li, Xiaomeng
Song, Meijun
Huang, Xiaojun
Mu, Deguang
author_sort Jiang, Luxi
collection PubMed
description BACKGROUND: Legionella pneumophila is an opportunistic waterborne pathogen of significant public health problems, which can cause serious human respiratory diseases (Legionnaires’ disease). Multiple cross displacement amplification (MCDA), a isothermal nucleic acid amplification technique, has been applied in the rapid detection of several bacterial agents. In this report, we developed a MCDA coupled with Nanoparticles-based Lateral Flow Biosensor (MCDA-LFB) for the rapid detection of L. pneumophila. RESULTS: A set of 10 primers based on the L. pneumophila specific mip gene to specifically identify 10 different target sequence regions of L. pneumophila was designed. The optimal time and temperature for amplification are 57 min and 65 °C. The limit of detection (LoD) is 10 fg in pure cultures of L. pneumophila. No cross-reaction was obtained and the specificity of MCDA-LFB assay was 100%. The whole process of the assay, including 20 min of DNA preparation, 35 min of L. pneumophila-MCDA reaction, and 2 min of sensor strip reaction, took a total of 57 min (less than 1 h). Among 88 specimens for clinical evaluation, 5 (5.68%) samples were L. pneumophila-positive by MCDA-LFB and traditional culture method, while 4(4.55%) samples were L. pneumophila-positive by PCR method targeting mip gene. Compared with culture method, the diagnostic accuracy of MCDA-LFB method was higher. CONCLUSIONS: In summary, the L. pneumophila-MCDA-LFB method we successfully developed is a simple, fast, reliable and sensitive diagnostic tool, which can be widely used in basic and clinical laboratories. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12866-021-02363-3.
format Online
Article
Text
id pubmed-8742375
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-87423752022-01-10 Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila Jiang, Luxi Gu, Rumeng Li, Xiaomeng Song, Meijun Huang, Xiaojun Mu, Deguang BMC Microbiol Research BACKGROUND: Legionella pneumophila is an opportunistic waterborne pathogen of significant public health problems, which can cause serious human respiratory diseases (Legionnaires’ disease). Multiple cross displacement amplification (MCDA), a isothermal nucleic acid amplification technique, has been applied in the rapid detection of several bacterial agents. In this report, we developed a MCDA coupled with Nanoparticles-based Lateral Flow Biosensor (MCDA-LFB) for the rapid detection of L. pneumophila. RESULTS: A set of 10 primers based on the L. pneumophila specific mip gene to specifically identify 10 different target sequence regions of L. pneumophila was designed. The optimal time and temperature for amplification are 57 min and 65 °C. The limit of detection (LoD) is 10 fg in pure cultures of L. pneumophila. No cross-reaction was obtained and the specificity of MCDA-LFB assay was 100%. The whole process of the assay, including 20 min of DNA preparation, 35 min of L. pneumophila-MCDA reaction, and 2 min of sensor strip reaction, took a total of 57 min (less than 1 h). Among 88 specimens for clinical evaluation, 5 (5.68%) samples were L. pneumophila-positive by MCDA-LFB and traditional culture method, while 4(4.55%) samples were L. pneumophila-positive by PCR method targeting mip gene. Compared with culture method, the diagnostic accuracy of MCDA-LFB method was higher. CONCLUSIONS: In summary, the L. pneumophila-MCDA-LFB method we successfully developed is a simple, fast, reliable and sensitive diagnostic tool, which can be widely used in basic and clinical laboratories. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12866-021-02363-3. BioMed Central 2022-01-08 /pmc/articles/PMC8742375/ /pubmed/34996350 http://dx.doi.org/10.1186/s12866-021-02363-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Jiang, Luxi
Gu, Rumeng
Li, Xiaomeng
Song, Meijun
Huang, Xiaojun
Mu, Deguang
Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila
title Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila
title_full Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila
title_fullStr Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila
title_full_unstemmed Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila
title_short Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila
title_sort multiple cross displacement amplification coupled with lateral flow biosensor (mcda-lfb) for rapid detection of legionella pneumophila
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8742375/
https://www.ncbi.nlm.nih.gov/pubmed/34996350
http://dx.doi.org/10.1186/s12866-021-02363-3
work_keys_str_mv AT jiangluxi multiplecrossdisplacementamplificationcoupledwithlateralflowbiosensormcdalfbforrapiddetectionoflegionellapneumophila
AT gurumeng multiplecrossdisplacementamplificationcoupledwithlateralflowbiosensormcdalfbforrapiddetectionoflegionellapneumophila
AT lixiaomeng multiplecrossdisplacementamplificationcoupledwithlateralflowbiosensormcdalfbforrapiddetectionoflegionellapneumophila
AT songmeijun multiplecrossdisplacementamplificationcoupledwithlateralflowbiosensormcdalfbforrapiddetectionoflegionellapneumophila
AT huangxiaojun multiplecrossdisplacementamplificationcoupledwithlateralflowbiosensormcdalfbforrapiddetectionoflegionellapneumophila
AT mudeguang multiplecrossdisplacementamplificationcoupledwithlateralflowbiosensormcdalfbforrapiddetectionoflegionellapneumophila