Cargando…

Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction

OBJECTIVE: To compare the effects of bone suppression imaging using deep learning (BSp-DL) based on a generative adversarial network (GAN) and bone subtraction imaging using a dual energy technique (BSt-DE) on radiologists’ performance for pulmonary nodule detection on chest radiographs (CXRs). MATE...

Descripción completa

Detalles Bibliográficos
Autores principales: Bae, Kyungsoo, Oh, Dong Yul, Yun, Il Dong, Jeon, Kyung Nyeo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8743147/
https://www.ncbi.nlm.nih.gov/pubmed/34983100
http://dx.doi.org/10.3348/kjr.2021.0146
_version_ 1784629846748430336
author Bae, Kyungsoo
Oh, Dong Yul
Yun, Il Dong
Jeon, Kyung Nyeo
author_facet Bae, Kyungsoo
Oh, Dong Yul
Yun, Il Dong
Jeon, Kyung Nyeo
author_sort Bae, Kyungsoo
collection PubMed
description OBJECTIVE: To compare the effects of bone suppression imaging using deep learning (BSp-DL) based on a generative adversarial network (GAN) and bone subtraction imaging using a dual energy technique (BSt-DE) on radiologists’ performance for pulmonary nodule detection on chest radiographs (CXRs). MATERIALS AND METHODS: A total of 111 adults, including 49 patients with 83 pulmonary nodules, who underwent both CXR using the dual energy technique and chest CT, were enrolled. Using CT as a reference, two independent radiologists evaluated CXR images for the presence or absence of pulmonary nodules in three reading sessions (standard CXR, BSt-DE CXR, and BSp-DL CXR). Person-wise and nodule-wise performances were assessed using receiver-operating characteristic (ROC) and alternative free-response ROC (AFROC) curve analyses, respectively. Subgroup analyses based on nodule size, location, and the presence of overlapping bones were performed. RESULTS: BSt-DE with an area under the AFROC curve (AUAFROC) of 0.996 and 0.976 for readers 1 and 2, respectively, and BSp-DL with AUAFROC of 0.981 and 0.958, respectively, showed better nodule-wise performance than standard CXR (AUAFROC of 0.907 and 0.808, respectively; p ≤ 0.005). In the person-wise analysis, BSp-DL with an area under the ROC curve (AUROC) of 0.984 and 0.931 for readers 1 and 2, respectively, showed better performance than standard CXR (AUROC of 0.915 and 0.798, respectively; p ≤ 0.011) and comparable performance to BSt-DE (AUROC of 0.988 and 0.974; p ≥ 0.064). BSt-DE and BSp-DL were superior to standard CXR for detecting nodules overlapping with bones (p < 0.017) or in the upper/middle lung zone (p < 0.017). BSt-DE was superior (p < 0.017) to BSp-DL in detecting peripheral and sub-centimeter nodules. CONCLUSION: BSp-DL (GAN-based bone suppression) showed comparable performance to BSt-DE and can improve radiologists’ performance in detecting pulmonary nodules on CXRs. Nevertheless, for better delineation of small and peripheral nodules, further technical improvements are required.
format Online
Article
Text
id pubmed-8743147
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-87431472022-01-18 Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction Bae, Kyungsoo Oh, Dong Yul Yun, Il Dong Jeon, Kyung Nyeo Korean J Radiol Thoracic Imaging OBJECTIVE: To compare the effects of bone suppression imaging using deep learning (BSp-DL) based on a generative adversarial network (GAN) and bone subtraction imaging using a dual energy technique (BSt-DE) on radiologists’ performance for pulmonary nodule detection on chest radiographs (CXRs). MATERIALS AND METHODS: A total of 111 adults, including 49 patients with 83 pulmonary nodules, who underwent both CXR using the dual energy technique and chest CT, were enrolled. Using CT as a reference, two independent radiologists evaluated CXR images for the presence or absence of pulmonary nodules in three reading sessions (standard CXR, BSt-DE CXR, and BSp-DL CXR). Person-wise and nodule-wise performances were assessed using receiver-operating characteristic (ROC) and alternative free-response ROC (AFROC) curve analyses, respectively. Subgroup analyses based on nodule size, location, and the presence of overlapping bones were performed. RESULTS: BSt-DE with an area under the AFROC curve (AUAFROC) of 0.996 and 0.976 for readers 1 and 2, respectively, and BSp-DL with AUAFROC of 0.981 and 0.958, respectively, showed better nodule-wise performance than standard CXR (AUAFROC of 0.907 and 0.808, respectively; p ≤ 0.005). In the person-wise analysis, BSp-DL with an area under the ROC curve (AUROC) of 0.984 and 0.931 for readers 1 and 2, respectively, showed better performance than standard CXR (AUROC of 0.915 and 0.798, respectively; p ≤ 0.011) and comparable performance to BSt-DE (AUROC of 0.988 and 0.974; p ≥ 0.064). BSt-DE and BSp-DL were superior to standard CXR for detecting nodules overlapping with bones (p < 0.017) or in the upper/middle lung zone (p < 0.017). BSt-DE was superior (p < 0.017) to BSp-DL in detecting peripheral and sub-centimeter nodules. CONCLUSION: BSp-DL (GAN-based bone suppression) showed comparable performance to BSt-DE and can improve radiologists’ performance in detecting pulmonary nodules on CXRs. Nevertheless, for better delineation of small and peripheral nodules, further technical improvements are required. The Korean Society of Radiology 2022-01 2022-01-03 /pmc/articles/PMC8743147/ /pubmed/34983100 http://dx.doi.org/10.3348/kjr.2021.0146 Text en Copyright © 2022 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Thoracic Imaging
Bae, Kyungsoo
Oh, Dong Yul
Yun, Il Dong
Jeon, Kyung Nyeo
Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction
title Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction
title_full Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction
title_fullStr Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction
title_full_unstemmed Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction
title_short Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction
title_sort bone suppression on chest radiographs for pulmonary nodule detection: comparison between a generative adversarial network and dual-energy subtraction
topic Thoracic Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8743147/
https://www.ncbi.nlm.nih.gov/pubmed/34983100
http://dx.doi.org/10.3348/kjr.2021.0146
work_keys_str_mv AT baekyungsoo bonesuppressiononchestradiographsforpulmonarynoduledetectioncomparisonbetweenagenerativeadversarialnetworkanddualenergysubtraction
AT ohdongyul bonesuppressiononchestradiographsforpulmonarynoduledetectioncomparisonbetweenagenerativeadversarialnetworkanddualenergysubtraction
AT yunildong bonesuppressiononchestradiographsforpulmonarynoduledetectioncomparisonbetweenagenerativeadversarialnetworkanddualenergysubtraction
AT jeonkyungnyeo bonesuppressiononchestradiographsforpulmonarynoduledetectioncomparisonbetweenagenerativeadversarialnetworkanddualenergysubtraction