Cargando…

Improving the Specificity of CT Angiography for the Diagnosis of Hepatic Artery Occlusion after Liver Transplantation in Suspected Patients with Doppler Ultrasound Abnormalities

OBJECTIVE: To investigate whether the diagnostic performance of CT angiography (CTA) could be improved by modifying the conventional criterion (anastomosis site abnormality) to diagnose hepatic artery occlusion (HAO) after liver transplantation (LT) in suspected patients with Doppler ultrasound (US)...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jin Sil, Kim, Dong Wook, Kim, Kyoung Won, Song, Gi Won, Lee, Sung Gyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8743154/
https://www.ncbi.nlm.nih.gov/pubmed/34983093
http://dx.doi.org/10.3348/kjr.2021.0266
_version_ 1784629848639012864
author Kim, Jin Sil
Kim, Dong Wook
Kim, Kyoung Won
Song, Gi Won
Lee, Sung Gyu
author_facet Kim, Jin Sil
Kim, Dong Wook
Kim, Kyoung Won
Song, Gi Won
Lee, Sung Gyu
author_sort Kim, Jin Sil
collection PubMed
description OBJECTIVE: To investigate whether the diagnostic performance of CT angiography (CTA) could be improved by modifying the conventional criterion (anastomosis site abnormality) to diagnose hepatic artery occlusion (HAO) after liver transplantation (LT) in suspected patients with Doppler ultrasound (US) abnormalities. MATERIALS AND METHODS: One hundred thirty-four adult LT recipients (88 males and 46 females; mean age, 52.7 years) with suspected HAO on Doppler US (40 HAO and 94 non-HAO according to the reference standards) were included. We evaluated 1) abnormalities in the HA anastomosis, categorized as a cutoff, ≥ 50% stenosis at the anastomotic site, or diffuse stenosis at both graft and recipient sides around the anastomosis, and 2) abnormalities in the distal run-off, including invisibility or irregular, faint, and discontinuous enhancement. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional (considering anastomosis site abnormalities alone) and modified CTA criteria (abnormalities in both the anastomosis site and distal run-off) for the diagnosis of HAO were calculated and compared using the McNemar test. RESULTS: By using the conventional criterion to diagnose HAO, the sensitivity, specificity, PPV, NPV, and accuracy were 100% (40/40), 74.5% (70/94), 62.5% (40/64), 100% (70/70), and 82.1% (110/134), respectively. The modified criterion for diagnosing HAO showed significantly increased specificity (93.6%, 88/94) and accuracy (93.3%, 125/134) compared to that with the conventional criterion (p = 0.001 and 0.002, respectively), although the sensitivity (92.5%, 37/40) decreased slightly without statistical significance (p = 0.250). CONCLUSION: The modified criterion considering abnormalities in both the anastomosis site and distal run-off improved the diagnostic performance of CTA for HAO in suspected patients with Doppler US abnormalities, particularly by increasing the specificity.
format Online
Article
Text
id pubmed-8743154
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-87431542022-01-18 Improving the Specificity of CT Angiography for the Diagnosis of Hepatic Artery Occlusion after Liver Transplantation in Suspected Patients with Doppler Ultrasound Abnormalities Kim, Jin Sil Kim, Dong Wook Kim, Kyoung Won Song, Gi Won Lee, Sung Gyu Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To investigate whether the diagnostic performance of CT angiography (CTA) could be improved by modifying the conventional criterion (anastomosis site abnormality) to diagnose hepatic artery occlusion (HAO) after liver transplantation (LT) in suspected patients with Doppler ultrasound (US) abnormalities. MATERIALS AND METHODS: One hundred thirty-four adult LT recipients (88 males and 46 females; mean age, 52.7 years) with suspected HAO on Doppler US (40 HAO and 94 non-HAO according to the reference standards) were included. We evaluated 1) abnormalities in the HA anastomosis, categorized as a cutoff, ≥ 50% stenosis at the anastomotic site, or diffuse stenosis at both graft and recipient sides around the anastomosis, and 2) abnormalities in the distal run-off, including invisibility or irregular, faint, and discontinuous enhancement. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional (considering anastomosis site abnormalities alone) and modified CTA criteria (abnormalities in both the anastomosis site and distal run-off) for the diagnosis of HAO were calculated and compared using the McNemar test. RESULTS: By using the conventional criterion to diagnose HAO, the sensitivity, specificity, PPV, NPV, and accuracy were 100% (40/40), 74.5% (70/94), 62.5% (40/64), 100% (70/70), and 82.1% (110/134), respectively. The modified criterion for diagnosing HAO showed significantly increased specificity (93.6%, 88/94) and accuracy (93.3%, 125/134) compared to that with the conventional criterion (p = 0.001 and 0.002, respectively), although the sensitivity (92.5%, 37/40) decreased slightly without statistical significance (p = 0.250). CONCLUSION: The modified criterion considering abnormalities in both the anastomosis site and distal run-off improved the diagnostic performance of CTA for HAO in suspected patients with Doppler US abnormalities, particularly by increasing the specificity. The Korean Society of Radiology 2022-01 2022-01-03 /pmc/articles/PMC8743154/ /pubmed/34983093 http://dx.doi.org/10.3348/kjr.2021.0266 Text en Copyright © 2022 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Gastrointestinal Imaging
Kim, Jin Sil
Kim, Dong Wook
Kim, Kyoung Won
Song, Gi Won
Lee, Sung Gyu
Improving the Specificity of CT Angiography for the Diagnosis of Hepatic Artery Occlusion after Liver Transplantation in Suspected Patients with Doppler Ultrasound Abnormalities
title Improving the Specificity of CT Angiography for the Diagnosis of Hepatic Artery Occlusion after Liver Transplantation in Suspected Patients with Doppler Ultrasound Abnormalities
title_full Improving the Specificity of CT Angiography for the Diagnosis of Hepatic Artery Occlusion after Liver Transplantation in Suspected Patients with Doppler Ultrasound Abnormalities
title_fullStr Improving the Specificity of CT Angiography for the Diagnosis of Hepatic Artery Occlusion after Liver Transplantation in Suspected Patients with Doppler Ultrasound Abnormalities
title_full_unstemmed Improving the Specificity of CT Angiography for the Diagnosis of Hepatic Artery Occlusion after Liver Transplantation in Suspected Patients with Doppler Ultrasound Abnormalities
title_short Improving the Specificity of CT Angiography for the Diagnosis of Hepatic Artery Occlusion after Liver Transplantation in Suspected Patients with Doppler Ultrasound Abnormalities
title_sort improving the specificity of ct angiography for the diagnosis of hepatic artery occlusion after liver transplantation in suspected patients with doppler ultrasound abnormalities
topic Gastrointestinal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8743154/
https://www.ncbi.nlm.nih.gov/pubmed/34983093
http://dx.doi.org/10.3348/kjr.2021.0266
work_keys_str_mv AT kimjinsil improvingthespecificityofctangiographyforthediagnosisofhepaticarteryocclusionafterlivertransplantationinsuspectedpatientswithdopplerultrasoundabnormalities
AT kimdongwook improvingthespecificityofctangiographyforthediagnosisofhepaticarteryocclusionafterlivertransplantationinsuspectedpatientswithdopplerultrasoundabnormalities
AT kimkyoungwon improvingthespecificityofctangiographyforthediagnosisofhepaticarteryocclusionafterlivertransplantationinsuspectedpatientswithdopplerultrasoundabnormalities
AT songgiwon improvingthespecificityofctangiographyforthediagnosisofhepaticarteryocclusionafterlivertransplantationinsuspectedpatientswithdopplerultrasoundabnormalities
AT leesunggyu improvingthespecificityofctangiographyforthediagnosisofhepaticarteryocclusionafterlivertransplantationinsuspectedpatientswithdopplerultrasoundabnormalities