Cargando…

Particle-Size-Dependent Filtration Efficiency, Breathability, and Flow Resistance of Face Coverings and Common Household Fabrics Used for Face Masks During the COVID-19 Pandemic

During the COVID-19 pandemic, the increase in demand for protective equipment caused a global shortage and homemade barrier face coverings were recommended as alternatives. However, filtration performances of homemade face coverings have not been fully evaluated. Test methods in the ASTM standard (F...

Descripción completa

Detalles Bibliográficos
Autores principales: Ayodeji, Olukayode James, Hilliard, Terrell A., Ramkumar, Seshadri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8743850/
https://www.ncbi.nlm.nih.gov/pubmed/35035493
http://dx.doi.org/10.1007/s41742-021-00390-6
_version_ 1784630003174998016
author Ayodeji, Olukayode James
Hilliard, Terrell A.
Ramkumar, Seshadri
author_facet Ayodeji, Olukayode James
Hilliard, Terrell A.
Ramkumar, Seshadri
author_sort Ayodeji, Olukayode James
collection PubMed
description During the COVID-19 pandemic, the increase in demand for protective equipment caused a global shortage and homemade barrier face coverings were recommended as alternatives. However, filtration performances of homemade face coverings have not been fully evaluated. Test methods in the ASTM standard (F3502-21) were used to evaluate filtration efficiencies (FE) and breathability (pressure drop, Δp) of face coverings and home fabric materials commonly used during the pandemic. Submicron particulates FE was measured by particle transmission through face covering samples using a Condensation Particle Counter equipped with differential mobility analyzer and electronic manometer. Flow resistance of 0.1 μm-diameter fluorescent nanoparticles in droplets was determined by measuring fluorescence intensity of residual collected at the reverse side of samples. The size-dependent FE (3–94%) and Δp (0.8–72 mmH(2)O) varied considerably among fabrics. Of the 16 mask types, 31.25% and 81.25% met the minimum FE and breathability standards in the ASTM F3502-21, respectively. Overall performance (qF) was highest for velcro masks (max qF = 3.36, min qF = 2.80) and lowest for Dutch wax print fabrics (max qF = 0.12, min qF = 0.03). Most of the samples resisted the flow of 0.1 µm-diameter nanoparticles in droplets. Low flow resistance was observed in bandana, neck gaiter, t-shirt I, tank top and bedspread fabrics. GSM and fabric finishing seems to affect performance. Low performances can be improved by selecting optimum-performance fabrics in the design and manufacture of barrier face coverings. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s41742-021-00390-6.
format Online
Article
Text
id pubmed-8743850
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-87438502022-01-10 Particle-Size-Dependent Filtration Efficiency, Breathability, and Flow Resistance of Face Coverings and Common Household Fabrics Used for Face Masks During the COVID-19 Pandemic Ayodeji, Olukayode James Hilliard, Terrell A. Ramkumar, Seshadri Int J Environ Res Research Paper During the COVID-19 pandemic, the increase in demand for protective equipment caused a global shortage and homemade barrier face coverings were recommended as alternatives. However, filtration performances of homemade face coverings have not been fully evaluated. Test methods in the ASTM standard (F3502-21) were used to evaluate filtration efficiencies (FE) and breathability (pressure drop, Δp) of face coverings and home fabric materials commonly used during the pandemic. Submicron particulates FE was measured by particle transmission through face covering samples using a Condensation Particle Counter equipped with differential mobility analyzer and electronic manometer. Flow resistance of 0.1 μm-diameter fluorescent nanoparticles in droplets was determined by measuring fluorescence intensity of residual collected at the reverse side of samples. The size-dependent FE (3–94%) and Δp (0.8–72 mmH(2)O) varied considerably among fabrics. Of the 16 mask types, 31.25% and 81.25% met the minimum FE and breathability standards in the ASTM F3502-21, respectively. Overall performance (qF) was highest for velcro masks (max qF = 3.36, min qF = 2.80) and lowest for Dutch wax print fabrics (max qF = 0.12, min qF = 0.03). Most of the samples resisted the flow of 0.1 µm-diameter nanoparticles in droplets. Low flow resistance was observed in bandana, neck gaiter, t-shirt I, tank top and bedspread fabrics. GSM and fabric finishing seems to affect performance. Low performances can be improved by selecting optimum-performance fabrics in the design and manufacture of barrier face coverings. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s41742-021-00390-6. Springer International Publishing 2022-01-10 2022 /pmc/articles/PMC8743850/ /pubmed/35035493 http://dx.doi.org/10.1007/s41742-021-00390-6 Text en © University of Tehran 2022 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Research Paper
Ayodeji, Olukayode James
Hilliard, Terrell A.
Ramkumar, Seshadri
Particle-Size-Dependent Filtration Efficiency, Breathability, and Flow Resistance of Face Coverings and Common Household Fabrics Used for Face Masks During the COVID-19 Pandemic
title Particle-Size-Dependent Filtration Efficiency, Breathability, and Flow Resistance of Face Coverings and Common Household Fabrics Used for Face Masks During the COVID-19 Pandemic
title_full Particle-Size-Dependent Filtration Efficiency, Breathability, and Flow Resistance of Face Coverings and Common Household Fabrics Used for Face Masks During the COVID-19 Pandemic
title_fullStr Particle-Size-Dependent Filtration Efficiency, Breathability, and Flow Resistance of Face Coverings and Common Household Fabrics Used for Face Masks During the COVID-19 Pandemic
title_full_unstemmed Particle-Size-Dependent Filtration Efficiency, Breathability, and Flow Resistance of Face Coverings and Common Household Fabrics Used for Face Masks During the COVID-19 Pandemic
title_short Particle-Size-Dependent Filtration Efficiency, Breathability, and Flow Resistance of Face Coverings and Common Household Fabrics Used for Face Masks During the COVID-19 Pandemic
title_sort particle-size-dependent filtration efficiency, breathability, and flow resistance of face coverings and common household fabrics used for face masks during the covid-19 pandemic
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8743850/
https://www.ncbi.nlm.nih.gov/pubmed/35035493
http://dx.doi.org/10.1007/s41742-021-00390-6
work_keys_str_mv AT ayodejiolukayodejames particlesizedependentfiltrationefficiencybreathabilityandflowresistanceoffacecoveringsandcommonhouseholdfabricsusedforfacemasksduringthecovid19pandemic
AT hilliardterrella particlesizedependentfiltrationefficiencybreathabilityandflowresistanceoffacecoveringsandcommonhouseholdfabricsusedforfacemasksduringthecovid19pandemic
AT ramkumarseshadri particlesizedependentfiltrationefficiencybreathabilityandflowresistanceoffacecoveringsandcommonhouseholdfabricsusedforfacemasksduringthecovid19pandemic