Cargando…

Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine

Purpose: The aim of this study was to evaluate the diagnostic accuracy of optical coherence tomography (OCT) and retinography in the detection of glaucoma through a telemedicine program. Methods: A population-based sample of 4113 persons was randomly selected. The screening examination included a fu...

Descripción completa

Detalles Bibliográficos
Autores principales: Anton, Alfonso, Nolivos, Karen, Pazos, Marta, Fatti, Gianluca, Ayala, Miriam Eleonora, Martínez-Prats, Elena, Peral, Oscar, Poposki, Vladimir, Tsiroukis, Evangelos, Morilla-Grasa, Antonio, Comas, Merce, Castells, Xavier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8746039/
https://www.ncbi.nlm.nih.gov/pubmed/35011957
http://dx.doi.org/10.3390/jcm11010216
_version_ 1784630488631083008
author Anton, Alfonso
Nolivos, Karen
Pazos, Marta
Fatti, Gianluca
Ayala, Miriam Eleonora
Martínez-Prats, Elena
Peral, Oscar
Poposki, Vladimir
Tsiroukis, Evangelos
Morilla-Grasa, Antonio
Comas, Merce
Castells, Xavier
author_facet Anton, Alfonso
Nolivos, Karen
Pazos, Marta
Fatti, Gianluca
Ayala, Miriam Eleonora
Martínez-Prats, Elena
Peral, Oscar
Poposki, Vladimir
Tsiroukis, Evangelos
Morilla-Grasa, Antonio
Comas, Merce
Castells, Xavier
author_sort Anton, Alfonso
collection PubMed
description Purpose: The aim of this study was to evaluate the diagnostic accuracy of optical coherence tomography (OCT) and retinography in the detection of glaucoma through a telemedicine program. Methods: A population-based sample of 4113 persons was randomly selected. The screening examination included a fundus photograph and OCT images. Images were evaluated on a deferred basis. All participants were then invited to a complete glaucoma examination, including gonioscopy, visual field, and dilated fundus examination. The detection rate, sensitivity, specificity, and positive and negative predictive values were calculated. Results: We screened 1006 persons. Of these, 201 (19.9%) were classified as glaucoma suspects; 20.4% were identified only by retinographs, 11.9% only by OCT images, and 46.3% by both. On ophthalmic examination at the hospital (n = 481), confirmed glaucoma was found in 58 (12.1%), probable glaucoma in 76 (15.8%), and ocular hypertension in 10 (2.1%), and no evidence of glaucoma was found in 337 (70.0%). The detection rate for confirmed or probable glaucoma was 9.2%. Sensitivity ranged from 69.4% to 86.2% and specificity from 82.1% to 97.4%, depending on the definition applied. Conclusions: The combination of OCT images and fundus photographs yielded a detection rate of 9.2% in a population-based screening program with moderate sensitivity, high specificity, and predictive values of 84–96%.
format Online
Article
Text
id pubmed-8746039
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87460392022-01-11 Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine Anton, Alfonso Nolivos, Karen Pazos, Marta Fatti, Gianluca Ayala, Miriam Eleonora Martínez-Prats, Elena Peral, Oscar Poposki, Vladimir Tsiroukis, Evangelos Morilla-Grasa, Antonio Comas, Merce Castells, Xavier J Clin Med Article Purpose: The aim of this study was to evaluate the diagnostic accuracy of optical coherence tomography (OCT) and retinography in the detection of glaucoma through a telemedicine program. Methods: A population-based sample of 4113 persons was randomly selected. The screening examination included a fundus photograph and OCT images. Images were evaluated on a deferred basis. All participants were then invited to a complete glaucoma examination, including gonioscopy, visual field, and dilated fundus examination. The detection rate, sensitivity, specificity, and positive and negative predictive values were calculated. Results: We screened 1006 persons. Of these, 201 (19.9%) were classified as glaucoma suspects; 20.4% were identified only by retinographs, 11.9% only by OCT images, and 46.3% by both. On ophthalmic examination at the hospital (n = 481), confirmed glaucoma was found in 58 (12.1%), probable glaucoma in 76 (15.8%), and ocular hypertension in 10 (2.1%), and no evidence of glaucoma was found in 337 (70.0%). The detection rate for confirmed or probable glaucoma was 9.2%. Sensitivity ranged from 69.4% to 86.2% and specificity from 82.1% to 97.4%, depending on the definition applied. Conclusions: The combination of OCT images and fundus photographs yielded a detection rate of 9.2% in a population-based screening program with moderate sensitivity, high specificity, and predictive values of 84–96%. MDPI 2021-12-31 /pmc/articles/PMC8746039/ /pubmed/35011957 http://dx.doi.org/10.3390/jcm11010216 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Anton, Alfonso
Nolivos, Karen
Pazos, Marta
Fatti, Gianluca
Ayala, Miriam Eleonora
Martínez-Prats, Elena
Peral, Oscar
Poposki, Vladimir
Tsiroukis, Evangelos
Morilla-Grasa, Antonio
Comas, Merce
Castells, Xavier
Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine
title Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine
title_full Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine
title_fullStr Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine
title_full_unstemmed Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine
title_short Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine
title_sort diagnostic accuracy and detection rate of glaucoma screening with optic disk photos, optical coherence tomography images, and telemedicine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8746039/
https://www.ncbi.nlm.nih.gov/pubmed/35011957
http://dx.doi.org/10.3390/jcm11010216
work_keys_str_mv AT antonalfonso diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT nolivoskaren diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT pazosmarta diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT fattigianluca diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT ayalamiriameleonora diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT martinezpratselena diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT peraloscar diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT poposkivladimir diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT tsiroukisevangelos diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT morillagrasaantonio diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT comasmerce diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine
AT castellsxavier diagnosticaccuracyanddetectionrateofglaucomascreeningwithopticdiskphotosopticalcoherencetomographyimagesandtelemedicine