Cargando…

Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis

A β-cyclodextrin-decorated magnetic activated carbon adsorbent was prepared and characterized using various analytical techniques (X-ray diffraction (XRD), scanning electron microscopy–electron diffraction spectroscopy (SEM-EDS) and transmission electron microscopy (TEM)), and the adsorbent was used...

Descripción completa

Detalles Bibliográficos
Autores principales: Mpupa, Anele, Nqombolo, Azile, Mizaikoff, Boris, Nomngongo, Philiswa Nosizo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747044/
https://www.ncbi.nlm.nih.gov/pubmed/35011480
http://dx.doi.org/10.3390/molecules27010248
_version_ 1784630735298101248
author Mpupa, Anele
Nqombolo, Azile
Mizaikoff, Boris
Nomngongo, Philiswa Nosizo
author_facet Mpupa, Anele
Nqombolo, Azile
Mizaikoff, Boris
Nomngongo, Philiswa Nosizo
author_sort Mpupa, Anele
collection PubMed
description A β-cyclodextrin-decorated magnetic activated carbon adsorbent was prepared and characterized using various analytical techniques (X-ray diffraction (XRD), scanning electron microscopy–electron diffraction spectroscopy (SEM-EDS) and transmission electron microscopy (TEM)), and the adsorbent was used in the development of a magnetic solid-phase microextraction (MSPE) method for the preconcentration of estrone, β-estradiol, hydrocortisone and progesterone in wastewater and river water samples. This method was optimized using the central composite design in order to determine the experimental parameters affecting the extraction procedure. The quantification of hormones was achieved using high-performance liquid chromatography equipped with a photodiode array detector (HPLC-DAD). Under optimum conditions, the linearity ranged from 0.04 to 300 µg L(−1) with a correlation of determinations of 0.9969–0.9991. The limits of detection and quantification were between 0.01–0.03 and 0.033–0.1 µg L(−1), with intraday and interday precisions at 1.1–3.4 and 3.2–4.2. The equilibrium data were best described by the Langmuir isotherm model, and high adsorption capacities (217–294 mg g(−1)) were obtained. The developed procedure demonstrated high potential as an effective technique for use in wastewater samples without significant interferences, and the adsorbent could be reused up to eight times.
format Online
Article
Text
id pubmed-8747044
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87470442022-01-11 Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis Mpupa, Anele Nqombolo, Azile Mizaikoff, Boris Nomngongo, Philiswa Nosizo Molecules Article A β-cyclodextrin-decorated magnetic activated carbon adsorbent was prepared and characterized using various analytical techniques (X-ray diffraction (XRD), scanning electron microscopy–electron diffraction spectroscopy (SEM-EDS) and transmission electron microscopy (TEM)), and the adsorbent was used in the development of a magnetic solid-phase microextraction (MSPE) method for the preconcentration of estrone, β-estradiol, hydrocortisone and progesterone in wastewater and river water samples. This method was optimized using the central composite design in order to determine the experimental parameters affecting the extraction procedure. The quantification of hormones was achieved using high-performance liquid chromatography equipped with a photodiode array detector (HPLC-DAD). Under optimum conditions, the linearity ranged from 0.04 to 300 µg L(−1) with a correlation of determinations of 0.9969–0.9991. The limits of detection and quantification were between 0.01–0.03 and 0.033–0.1 µg L(−1), with intraday and interday precisions at 1.1–3.4 and 3.2–4.2. The equilibrium data were best described by the Langmuir isotherm model, and high adsorption capacities (217–294 mg g(−1)) were obtained. The developed procedure demonstrated high potential as an effective technique for use in wastewater samples without significant interferences, and the adsorbent could be reused up to eight times. MDPI 2021-12-31 /pmc/articles/PMC8747044/ /pubmed/35011480 http://dx.doi.org/10.3390/molecules27010248 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mpupa, Anele
Nqombolo, Azile
Mizaikoff, Boris
Nomngongo, Philiswa Nosizo
Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis
title Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis
title_full Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis
title_fullStr Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis
title_full_unstemmed Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis
title_short Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis
title_sort beta-cyclodextrin-decorated magnetic activated carbon as a sorbent for extraction and enrichment of steroid hormones (estrone, β-estradiol, hydrocortisone and progesterone) for liquid chromatographic analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747044/
https://www.ncbi.nlm.nih.gov/pubmed/35011480
http://dx.doi.org/10.3390/molecules27010248
work_keys_str_mv AT mpupaanele betacyclodextrindecoratedmagneticactivatedcarbonasasorbentforextractionandenrichmentofsteroidhormonesestronebestradiolhydrocortisoneandprogesteroneforliquidchromatographicanalysis
AT nqomboloazile betacyclodextrindecoratedmagneticactivatedcarbonasasorbentforextractionandenrichmentofsteroidhormonesestronebestradiolhydrocortisoneandprogesteroneforliquidchromatographicanalysis
AT mizaikoffboris betacyclodextrindecoratedmagneticactivatedcarbonasasorbentforextractionandenrichmentofsteroidhormonesestronebestradiolhydrocortisoneandprogesteroneforliquidchromatographicanalysis
AT nomngongophiliswanosizo betacyclodextrindecoratedmagneticactivatedcarbonasasorbentforextractionandenrichmentofsteroidhormonesestronebestradiolhydrocortisoneandprogesteroneforliquidchromatographicanalysis