Cargando…
Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis
A β-cyclodextrin-decorated magnetic activated carbon adsorbent was prepared and characterized using various analytical techniques (X-ray diffraction (XRD), scanning electron microscopy–electron diffraction spectroscopy (SEM-EDS) and transmission electron microscopy (TEM)), and the adsorbent was used...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747044/ https://www.ncbi.nlm.nih.gov/pubmed/35011480 http://dx.doi.org/10.3390/molecules27010248 |
_version_ | 1784630735298101248 |
---|---|
author | Mpupa, Anele Nqombolo, Azile Mizaikoff, Boris Nomngongo, Philiswa Nosizo |
author_facet | Mpupa, Anele Nqombolo, Azile Mizaikoff, Boris Nomngongo, Philiswa Nosizo |
author_sort | Mpupa, Anele |
collection | PubMed |
description | A β-cyclodextrin-decorated magnetic activated carbon adsorbent was prepared and characterized using various analytical techniques (X-ray diffraction (XRD), scanning electron microscopy–electron diffraction spectroscopy (SEM-EDS) and transmission electron microscopy (TEM)), and the adsorbent was used in the development of a magnetic solid-phase microextraction (MSPE) method for the preconcentration of estrone, β-estradiol, hydrocortisone and progesterone in wastewater and river water samples. This method was optimized using the central composite design in order to determine the experimental parameters affecting the extraction procedure. The quantification of hormones was achieved using high-performance liquid chromatography equipped with a photodiode array detector (HPLC-DAD). Under optimum conditions, the linearity ranged from 0.04 to 300 µg L(−1) with a correlation of determinations of 0.9969–0.9991. The limits of detection and quantification were between 0.01–0.03 and 0.033–0.1 µg L(−1), with intraday and interday precisions at 1.1–3.4 and 3.2–4.2. The equilibrium data were best described by the Langmuir isotherm model, and high adsorption capacities (217–294 mg g(−1)) were obtained. The developed procedure demonstrated high potential as an effective technique for use in wastewater samples without significant interferences, and the adsorbent could be reused up to eight times. |
format | Online Article Text |
id | pubmed-8747044 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87470442022-01-11 Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis Mpupa, Anele Nqombolo, Azile Mizaikoff, Boris Nomngongo, Philiswa Nosizo Molecules Article A β-cyclodextrin-decorated magnetic activated carbon adsorbent was prepared and characterized using various analytical techniques (X-ray diffraction (XRD), scanning electron microscopy–electron diffraction spectroscopy (SEM-EDS) and transmission electron microscopy (TEM)), and the adsorbent was used in the development of a magnetic solid-phase microextraction (MSPE) method for the preconcentration of estrone, β-estradiol, hydrocortisone and progesterone in wastewater and river water samples. This method was optimized using the central composite design in order to determine the experimental parameters affecting the extraction procedure. The quantification of hormones was achieved using high-performance liquid chromatography equipped with a photodiode array detector (HPLC-DAD). Under optimum conditions, the linearity ranged from 0.04 to 300 µg L(−1) with a correlation of determinations of 0.9969–0.9991. The limits of detection and quantification were between 0.01–0.03 and 0.033–0.1 µg L(−1), with intraday and interday precisions at 1.1–3.4 and 3.2–4.2. The equilibrium data were best described by the Langmuir isotherm model, and high adsorption capacities (217–294 mg g(−1)) were obtained. The developed procedure demonstrated high potential as an effective technique for use in wastewater samples without significant interferences, and the adsorbent could be reused up to eight times. MDPI 2021-12-31 /pmc/articles/PMC8747044/ /pubmed/35011480 http://dx.doi.org/10.3390/molecules27010248 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mpupa, Anele Nqombolo, Azile Mizaikoff, Boris Nomngongo, Philiswa Nosizo Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis |
title | Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis |
title_full | Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis |
title_fullStr | Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis |
title_full_unstemmed | Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis |
title_short | Beta-Cyclodextrin-Decorated Magnetic Activated Carbon as a Sorbent for Extraction and Enrichment of Steroid Hormones (Estrone, β-Estradiol, Hydrocortisone and Progesterone) for Liquid Chromatographic Analysis |
title_sort | beta-cyclodextrin-decorated magnetic activated carbon as a sorbent for extraction and enrichment of steroid hormones (estrone, β-estradiol, hydrocortisone and progesterone) for liquid chromatographic analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747044/ https://www.ncbi.nlm.nih.gov/pubmed/35011480 http://dx.doi.org/10.3390/molecules27010248 |
work_keys_str_mv | AT mpupaanele betacyclodextrindecoratedmagneticactivatedcarbonasasorbentforextractionandenrichmentofsteroidhormonesestronebestradiolhydrocortisoneandprogesteroneforliquidchromatographicanalysis AT nqomboloazile betacyclodextrindecoratedmagneticactivatedcarbonasasorbentforextractionandenrichmentofsteroidhormonesestronebestradiolhydrocortisoneandprogesteroneforliquidchromatographicanalysis AT mizaikoffboris betacyclodextrindecoratedmagneticactivatedcarbonasasorbentforextractionandenrichmentofsteroidhormonesestronebestradiolhydrocortisoneandprogesteroneforliquidchromatographicanalysis AT nomngongophiliswanosizo betacyclodextrindecoratedmagneticactivatedcarbonasasorbentforextractionandenrichmentofsteroidhormonesestronebestradiolhydrocortisoneandprogesteroneforliquidchromatographicanalysis |