Cargando…

Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors

Vital signs such as heart rate and respiration rate are among the most important physiological signals for health monitoring and medical applications. Impulse radio (IR) ultra-wideband (UWB) radar becomes one of the essential sensors in non-contact vital signs detection. The heart pulse wave is easi...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Hongqiang, Ebrahim, Malikeh P., Hasan, Kareeb, Heydari, Fatemeh, Howley, Paul, Yuce, Mehmet Rasit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747437/
https://www.ncbi.nlm.nih.gov/pubmed/35009628
http://dx.doi.org/10.3390/s22010083
_version_ 1784630836372439040
author Xu, Hongqiang
Ebrahim, Malikeh P.
Hasan, Kareeb
Heydari, Fatemeh
Howley, Paul
Yuce, Mehmet Rasit
author_facet Xu, Hongqiang
Ebrahim, Malikeh P.
Hasan, Kareeb
Heydari, Fatemeh
Howley, Paul
Yuce, Mehmet Rasit
author_sort Xu, Hongqiang
collection PubMed
description Vital signs such as heart rate and respiration rate are among the most important physiological signals for health monitoring and medical applications. Impulse radio (IR) ultra-wideband (UWB) radar becomes one of the essential sensors in non-contact vital signs detection. The heart pulse wave is easily corrupted by noise and respiration activity since the heartbeat signal has less power compared with the breathing signal and its harmonics. In this paper, a signal processing technique for a UWB radar system was developed to detect the heart rate and respiration rate. There are four main stages of signal processing: (1) clutter removal to reduce the static random noise from the environment; (2) independent component analysis (ICA) to do dimension reduction and remove noise; (3) using low-pass and high-pass filters to eliminate the out of band noise; (4) modified covariance method for spectrum estimation. Furthermore, higher harmonics of heart rate were used to estimate heart rate and minimize respiration interference. The experiments in this article contain different scenarios including bed angle, body position, as well as interference from the visitor near the bed and away from the bed. The results were compared with the ECG sensor and respiration belt. The average mean absolute error (MAE) of heart rate results is 1.32 for the proposed algorithm.
format Online
Article
Text
id pubmed-8747437
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87474372022-01-11 Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors Xu, Hongqiang Ebrahim, Malikeh P. Hasan, Kareeb Heydari, Fatemeh Howley, Paul Yuce, Mehmet Rasit Sensors (Basel) Article Vital signs such as heart rate and respiration rate are among the most important physiological signals for health monitoring and medical applications. Impulse radio (IR) ultra-wideband (UWB) radar becomes one of the essential sensors in non-contact vital signs detection. The heart pulse wave is easily corrupted by noise and respiration activity since the heartbeat signal has less power compared with the breathing signal and its harmonics. In this paper, a signal processing technique for a UWB radar system was developed to detect the heart rate and respiration rate. There are four main stages of signal processing: (1) clutter removal to reduce the static random noise from the environment; (2) independent component analysis (ICA) to do dimension reduction and remove noise; (3) using low-pass and high-pass filters to eliminate the out of band noise; (4) modified covariance method for spectrum estimation. Furthermore, higher harmonics of heart rate were used to estimate heart rate and minimize respiration interference. The experiments in this article contain different scenarios including bed angle, body position, as well as interference from the visitor near the bed and away from the bed. The results were compared with the ECG sensor and respiration belt. The average mean absolute error (MAE) of heart rate results is 1.32 for the proposed algorithm. MDPI 2021-12-23 /pmc/articles/PMC8747437/ /pubmed/35009628 http://dx.doi.org/10.3390/s22010083 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xu, Hongqiang
Ebrahim, Malikeh P.
Hasan, Kareeb
Heydari, Fatemeh
Howley, Paul
Yuce, Mehmet Rasit
Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors
title Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors
title_full Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors
title_fullStr Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors
title_full_unstemmed Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors
title_short Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors
title_sort accurate heart rate and respiration rate detection based on a higher-order harmonics peak selection method using radar non-contact sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747437/
https://www.ncbi.nlm.nih.gov/pubmed/35009628
http://dx.doi.org/10.3390/s22010083
work_keys_str_mv AT xuhongqiang accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors
AT ebrahimmalikehp accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors
AT hasankareeb accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors
AT heydarifatemeh accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors
AT howleypaul accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors
AT yucemehmetrasit accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors