Cargando…
Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors
Vital signs such as heart rate and respiration rate are among the most important physiological signals for health monitoring and medical applications. Impulse radio (IR) ultra-wideband (UWB) radar becomes one of the essential sensors in non-contact vital signs detection. The heart pulse wave is easi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747437/ https://www.ncbi.nlm.nih.gov/pubmed/35009628 http://dx.doi.org/10.3390/s22010083 |
_version_ | 1784630836372439040 |
---|---|
author | Xu, Hongqiang Ebrahim, Malikeh P. Hasan, Kareeb Heydari, Fatemeh Howley, Paul Yuce, Mehmet Rasit |
author_facet | Xu, Hongqiang Ebrahim, Malikeh P. Hasan, Kareeb Heydari, Fatemeh Howley, Paul Yuce, Mehmet Rasit |
author_sort | Xu, Hongqiang |
collection | PubMed |
description | Vital signs such as heart rate and respiration rate are among the most important physiological signals for health monitoring and medical applications. Impulse radio (IR) ultra-wideband (UWB) radar becomes one of the essential sensors in non-contact vital signs detection. The heart pulse wave is easily corrupted by noise and respiration activity since the heartbeat signal has less power compared with the breathing signal and its harmonics. In this paper, a signal processing technique for a UWB radar system was developed to detect the heart rate and respiration rate. There are four main stages of signal processing: (1) clutter removal to reduce the static random noise from the environment; (2) independent component analysis (ICA) to do dimension reduction and remove noise; (3) using low-pass and high-pass filters to eliminate the out of band noise; (4) modified covariance method for spectrum estimation. Furthermore, higher harmonics of heart rate were used to estimate heart rate and minimize respiration interference. The experiments in this article contain different scenarios including bed angle, body position, as well as interference from the visitor near the bed and away from the bed. The results were compared with the ECG sensor and respiration belt. The average mean absolute error (MAE) of heart rate results is 1.32 for the proposed algorithm. |
format | Online Article Text |
id | pubmed-8747437 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87474372022-01-11 Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors Xu, Hongqiang Ebrahim, Malikeh P. Hasan, Kareeb Heydari, Fatemeh Howley, Paul Yuce, Mehmet Rasit Sensors (Basel) Article Vital signs such as heart rate and respiration rate are among the most important physiological signals for health monitoring and medical applications. Impulse radio (IR) ultra-wideband (UWB) radar becomes one of the essential sensors in non-contact vital signs detection. The heart pulse wave is easily corrupted by noise and respiration activity since the heartbeat signal has less power compared with the breathing signal and its harmonics. In this paper, a signal processing technique for a UWB radar system was developed to detect the heart rate and respiration rate. There are four main stages of signal processing: (1) clutter removal to reduce the static random noise from the environment; (2) independent component analysis (ICA) to do dimension reduction and remove noise; (3) using low-pass and high-pass filters to eliminate the out of band noise; (4) modified covariance method for spectrum estimation. Furthermore, higher harmonics of heart rate were used to estimate heart rate and minimize respiration interference. The experiments in this article contain different scenarios including bed angle, body position, as well as interference from the visitor near the bed and away from the bed. The results were compared with the ECG sensor and respiration belt. The average mean absolute error (MAE) of heart rate results is 1.32 for the proposed algorithm. MDPI 2021-12-23 /pmc/articles/PMC8747437/ /pubmed/35009628 http://dx.doi.org/10.3390/s22010083 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xu, Hongqiang Ebrahim, Malikeh P. Hasan, Kareeb Heydari, Fatemeh Howley, Paul Yuce, Mehmet Rasit Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors |
title | Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors |
title_full | Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors |
title_fullStr | Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors |
title_full_unstemmed | Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors |
title_short | Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors |
title_sort | accurate heart rate and respiration rate detection based on a higher-order harmonics peak selection method using radar non-contact sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747437/ https://www.ncbi.nlm.nih.gov/pubmed/35009628 http://dx.doi.org/10.3390/s22010083 |
work_keys_str_mv | AT xuhongqiang accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors AT ebrahimmalikehp accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors AT hasankareeb accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors AT heydarifatemeh accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors AT howleypaul accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors AT yucemehmetrasit accurateheartrateandrespirationratedetectionbasedonahigherorderharmonicspeakselectionmethodusingradarnoncontactsensors |