Cargando…
Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease
Dry powder inhalers (DPIs) are breath actuated, and patients using DPIs need to generate an optimal inspiratory flow during the inhalation maneuver for effective drug delivery to the lungs. However, practical and standardized recommendations for measuring peak inspiratory flow (PIF)—a potential indi...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747625/ https://www.ncbi.nlm.nih.gov/pubmed/35023914 http://dx.doi.org/10.2147/COPD.S319511 |
_version_ | 1784630873222545408 |
---|---|
author | Ohar, Jill A Ferguson, Gary T Mahler, Donald A Drummond, M Bradley Dhand, Rajiv Pleasants, Roy A Anzueto, Antonio Halpin, David M G Price, David B Drescher, Gail S Hoy, Haley M Haughney, John Hess, Michael W Usmani, Omar S |
author_facet | Ohar, Jill A Ferguson, Gary T Mahler, Donald A Drummond, M Bradley Dhand, Rajiv Pleasants, Roy A Anzueto, Antonio Halpin, David M G Price, David B Drescher, Gail S Hoy, Haley M Haughney, John Hess, Michael W Usmani, Omar S |
author_sort | Ohar, Jill A |
collection | PubMed |
description | Dry powder inhalers (DPIs) are breath actuated, and patients using DPIs need to generate an optimal inspiratory flow during the inhalation maneuver for effective drug delivery to the lungs. However, practical and standardized recommendations for measuring peak inspiratory flow (PIF)—a potential indicator for effective DPI use in chronic obstructive pulmonary disease (COPD)—are lacking. To evaluate recommended PIF assessment approaches, we reviewed the Instructions for Use of the In-Check™ DIAL and the prescribing information for eight DPIs approved for use in the treatment of COPD in the United States. To evaluate applied PIF assessment approaches, we conducted a PubMed search from inception to August 31, 2021, for reports of clinical and real-life studies where PIF was measured using the In-Check™ DIAL or through a DPI in patients with COPD. Evaluation of collective sources, including 47 applicable studies, showed that instructions related to the positioning of the patient with their DPI, instructions for exhalation before the inhalation maneuver, the inhalation maneuver itself, and post-inhalation breath-hold times varied, and in many instances, appeared vague and/or incomplete. We observed considerable variation in how PIF was measured in clinical and real-life studies, underscoring the need for a standardized method of PIF measurement. Standardization of technique will facilitate comparisons among studies. Based on these findings and our clinical and research experience, we propose specific recommendations for PIF measurement to standardize the process and better ensure accurate and reliable PIF values in clinical trials and in daily clinical practice. |
format | Online Article Text |
id | pubmed-8747625 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-87476252022-01-11 Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease Ohar, Jill A Ferguson, Gary T Mahler, Donald A Drummond, M Bradley Dhand, Rajiv Pleasants, Roy A Anzueto, Antonio Halpin, David M G Price, David B Drescher, Gail S Hoy, Haley M Haughney, John Hess, Michael W Usmani, Omar S Int J Chron Obstruct Pulmon Dis Review Dry powder inhalers (DPIs) are breath actuated, and patients using DPIs need to generate an optimal inspiratory flow during the inhalation maneuver for effective drug delivery to the lungs. However, practical and standardized recommendations for measuring peak inspiratory flow (PIF)—a potential indicator for effective DPI use in chronic obstructive pulmonary disease (COPD)—are lacking. To evaluate recommended PIF assessment approaches, we reviewed the Instructions for Use of the In-Check™ DIAL and the prescribing information for eight DPIs approved for use in the treatment of COPD in the United States. To evaluate applied PIF assessment approaches, we conducted a PubMed search from inception to August 31, 2021, for reports of clinical and real-life studies where PIF was measured using the In-Check™ DIAL or through a DPI in patients with COPD. Evaluation of collective sources, including 47 applicable studies, showed that instructions related to the positioning of the patient with their DPI, instructions for exhalation before the inhalation maneuver, the inhalation maneuver itself, and post-inhalation breath-hold times varied, and in many instances, appeared vague and/or incomplete. We observed considerable variation in how PIF was measured in clinical and real-life studies, underscoring the need for a standardized method of PIF measurement. Standardization of technique will facilitate comparisons among studies. Based on these findings and our clinical and research experience, we propose specific recommendations for PIF measurement to standardize the process and better ensure accurate and reliable PIF values in clinical trials and in daily clinical practice. Dove 2022-01-06 /pmc/articles/PMC8747625/ /pubmed/35023914 http://dx.doi.org/10.2147/COPD.S319511 Text en © 2022 Ohar et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Review Ohar, Jill A Ferguson, Gary T Mahler, Donald A Drummond, M Bradley Dhand, Rajiv Pleasants, Roy A Anzueto, Antonio Halpin, David M G Price, David B Drescher, Gail S Hoy, Haley M Haughney, John Hess, Michael W Usmani, Omar S Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease |
title | Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease |
title_full | Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease |
title_fullStr | Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease |
title_full_unstemmed | Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease |
title_short | Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease |
title_sort | measuring peak inspiratory flow in patients with chronic obstructive pulmonary disease |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747625/ https://www.ncbi.nlm.nih.gov/pubmed/35023914 http://dx.doi.org/10.2147/COPD.S319511 |
work_keys_str_mv | AT oharjilla measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT fergusongaryt measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT mahlerdonalda measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT drummondmbradley measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT dhandrajiv measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT pleasantsroya measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT anzuetoantonio measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT halpindavidmg measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT pricedavidb measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT dreschergails measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT hoyhaleym measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT haughneyjohn measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT hessmichaelw measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease AT usmaniomars measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease |