Cargando…

Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease

Dry powder inhalers (DPIs) are breath actuated, and patients using DPIs need to generate an optimal inspiratory flow during the inhalation maneuver for effective drug delivery to the lungs. However, practical and standardized recommendations for measuring peak inspiratory flow (PIF)—a potential indi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ohar, Jill A, Ferguson, Gary T, Mahler, Donald A, Drummond, M Bradley, Dhand, Rajiv, Pleasants, Roy A, Anzueto, Antonio, Halpin, David M G, Price, David B, Drescher, Gail S, Hoy, Haley M, Haughney, John, Hess, Michael W, Usmani, Omar S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747625/
https://www.ncbi.nlm.nih.gov/pubmed/35023914
http://dx.doi.org/10.2147/COPD.S319511
_version_ 1784630873222545408
author Ohar, Jill A
Ferguson, Gary T
Mahler, Donald A
Drummond, M Bradley
Dhand, Rajiv
Pleasants, Roy A
Anzueto, Antonio
Halpin, David M G
Price, David B
Drescher, Gail S
Hoy, Haley M
Haughney, John
Hess, Michael W
Usmani, Omar S
author_facet Ohar, Jill A
Ferguson, Gary T
Mahler, Donald A
Drummond, M Bradley
Dhand, Rajiv
Pleasants, Roy A
Anzueto, Antonio
Halpin, David M G
Price, David B
Drescher, Gail S
Hoy, Haley M
Haughney, John
Hess, Michael W
Usmani, Omar S
author_sort Ohar, Jill A
collection PubMed
description Dry powder inhalers (DPIs) are breath actuated, and patients using DPIs need to generate an optimal inspiratory flow during the inhalation maneuver for effective drug delivery to the lungs. However, practical and standardized recommendations for measuring peak inspiratory flow (PIF)—a potential indicator for effective DPI use in chronic obstructive pulmonary disease (COPD)—are lacking. To evaluate recommended PIF assessment approaches, we reviewed the Instructions for Use of the In-Check™ DIAL and the prescribing information for eight DPIs approved for use in the treatment of COPD in the United States. To evaluate applied PIF assessment approaches, we conducted a PubMed search from inception to August 31, 2021, for reports of clinical and real-life studies where PIF was measured using the In-Check™ DIAL or through a DPI in patients with COPD. Evaluation of collective sources, including 47 applicable studies, showed that instructions related to the positioning of the patient with their DPI, instructions for exhalation before the inhalation maneuver, the inhalation maneuver itself, and post-inhalation breath-hold times varied, and in many instances, appeared vague and/or incomplete. We observed considerable variation in how PIF was measured in clinical and real-life studies, underscoring the need for a standardized method of PIF measurement. Standardization of technique will facilitate comparisons among studies. Based on these findings and our clinical and research experience, we propose specific recommendations for PIF measurement to standardize the process and better ensure accurate and reliable PIF values in clinical trials and in daily clinical practice.
format Online
Article
Text
id pubmed-8747625
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-87476252022-01-11 Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease Ohar, Jill A Ferguson, Gary T Mahler, Donald A Drummond, M Bradley Dhand, Rajiv Pleasants, Roy A Anzueto, Antonio Halpin, David M G Price, David B Drescher, Gail S Hoy, Haley M Haughney, John Hess, Michael W Usmani, Omar S Int J Chron Obstruct Pulmon Dis Review Dry powder inhalers (DPIs) are breath actuated, and patients using DPIs need to generate an optimal inspiratory flow during the inhalation maneuver for effective drug delivery to the lungs. However, practical and standardized recommendations for measuring peak inspiratory flow (PIF)—a potential indicator for effective DPI use in chronic obstructive pulmonary disease (COPD)—are lacking. To evaluate recommended PIF assessment approaches, we reviewed the Instructions for Use of the In-Check™ DIAL and the prescribing information for eight DPIs approved for use in the treatment of COPD in the United States. To evaluate applied PIF assessment approaches, we conducted a PubMed search from inception to August 31, 2021, for reports of clinical and real-life studies where PIF was measured using the In-Check™ DIAL or through a DPI in patients with COPD. Evaluation of collective sources, including 47 applicable studies, showed that instructions related to the positioning of the patient with their DPI, instructions for exhalation before the inhalation maneuver, the inhalation maneuver itself, and post-inhalation breath-hold times varied, and in many instances, appeared vague and/or incomplete. We observed considerable variation in how PIF was measured in clinical and real-life studies, underscoring the need for a standardized method of PIF measurement. Standardization of technique will facilitate comparisons among studies. Based on these findings and our clinical and research experience, we propose specific recommendations for PIF measurement to standardize the process and better ensure accurate and reliable PIF values in clinical trials and in daily clinical practice. Dove 2022-01-06 /pmc/articles/PMC8747625/ /pubmed/35023914 http://dx.doi.org/10.2147/COPD.S319511 Text en © 2022 Ohar et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Review
Ohar, Jill A
Ferguson, Gary T
Mahler, Donald A
Drummond, M Bradley
Dhand, Rajiv
Pleasants, Roy A
Anzueto, Antonio
Halpin, David M G
Price, David B
Drescher, Gail S
Hoy, Haley M
Haughney, John
Hess, Michael W
Usmani, Omar S
Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease
title Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease
title_full Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease
title_fullStr Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease
title_full_unstemmed Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease
title_short Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease
title_sort measuring peak inspiratory flow in patients with chronic obstructive pulmonary disease
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747625/
https://www.ncbi.nlm.nih.gov/pubmed/35023914
http://dx.doi.org/10.2147/COPD.S319511
work_keys_str_mv AT oharjilla measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT fergusongaryt measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT mahlerdonalda measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT drummondmbradley measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT dhandrajiv measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT pleasantsroya measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT anzuetoantonio measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT halpindavidmg measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT pricedavidb measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT dreschergails measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT hoyhaleym measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT haughneyjohn measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT hessmichaelw measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease
AT usmaniomars measuringpeakinspiratoryflowinpatientswithchronicobstructivepulmonarydisease