Cargando…
Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment
BACKGROUND/AIMS: While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to determine the DRA reference diameters of Korean patients and identify the predictors of DRA diameter < 2.3 mm....
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Association of Internal Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747912/ https://www.ncbi.nlm.nih.gov/pubmed/35000375 http://dx.doi.org/10.3904/kjim.2020.685 |
_version_ | 1784630944631619584 |
---|---|
author | Lee, Jun-Won Son, Jung-Woo Go, Tae-Hwa Kang, Dae Ryong Lee, Sang Jun Kim, Se Eun Cho, Dong-Hyuk Park, Young Jun Youn, Young Jin Ahn, Min-Soo Ahn, Sung Gyun Kim, Jang-Young Yoo, Byung-Su Yoon, Junghan Lee, Seung-Hwan |
author_facet | Lee, Jun-Won Son, Jung-Woo Go, Tae-Hwa Kang, Dae Ryong Lee, Sang Jun Kim, Se Eun Cho, Dong-Hyuk Park, Young Jun Youn, Young Jin Ahn, Min-Soo Ahn, Sung Gyun Kim, Jang-Young Yoo, Byung-Su Yoon, Junghan Lee, Seung-Hwan |
author_sort | Lee, Jun-Won |
collection | PubMed |
description | BACKGROUND/AIMS: While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to determine the DRA reference diameters of Korean patients and identify the predictors of DRA diameter < 2.3 mm. METHODS: The outer bilateral DRA diameters were assessed using a linear ultrasound probe in 1,162 consecutive patients who underwent transthoracic echocardiography. The DRA diameter was measured by the perpendicular angle in the dorsum of the hand, and the average values were compared by sex. DRA diameter < 2.3 mm was defined as unsuitable for routine diagnostic coronary angiography using a 5 Fr introducer sheath. RESULTS: The mean DRA diameters were 2.31 ± 0.43 mm (right) and 2.35 ± 0.45 mm (left). The DRA was smaller in women than men (right: 2.15 ± 0.38 mm vs. 2.43 ± 0.44 mm, p < 0.001; left: 2.18 ± 0.39 mm vs. 2.47 ± 0.45 mm, p < 0.001). The DRA diameter was approximately 20% smaller than the radial artery diameter. A total of 630 (54.2%) and 574 (49.4%) patients had DRA diameter < 2.3 mm in the right and left hands, respectively. Female sex, low body mass index (BMI), and low body surface area (BSA) were significant predictors of DRA diameter < 2.3 mm. CONCLUSIONS: We provided reference DRA diameters for Korean patients. Approximately 50% of the studied patients had DRA diameter < 2.3 mm. Female sex, low BMI, and low BSA remained significant predictors of DRA diameter < 2.3 mm. |
format | Online Article Text |
id | pubmed-8747912 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Korean Association of Internal Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-87479122022-01-18 Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment Lee, Jun-Won Son, Jung-Woo Go, Tae-Hwa Kang, Dae Ryong Lee, Sang Jun Kim, Se Eun Cho, Dong-Hyuk Park, Young Jun Youn, Young Jin Ahn, Min-Soo Ahn, Sung Gyun Kim, Jang-Young Yoo, Byung-Su Yoon, Junghan Lee, Seung-Hwan Korean J Intern Med Original Article BACKGROUND/AIMS: While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to determine the DRA reference diameters of Korean patients and identify the predictors of DRA diameter < 2.3 mm. METHODS: The outer bilateral DRA diameters were assessed using a linear ultrasound probe in 1,162 consecutive patients who underwent transthoracic echocardiography. The DRA diameter was measured by the perpendicular angle in the dorsum of the hand, and the average values were compared by sex. DRA diameter < 2.3 mm was defined as unsuitable for routine diagnostic coronary angiography using a 5 Fr introducer sheath. RESULTS: The mean DRA diameters were 2.31 ± 0.43 mm (right) and 2.35 ± 0.45 mm (left). The DRA was smaller in women than men (right: 2.15 ± 0.38 mm vs. 2.43 ± 0.44 mm, p < 0.001; left: 2.18 ± 0.39 mm vs. 2.47 ± 0.45 mm, p < 0.001). The DRA diameter was approximately 20% smaller than the radial artery diameter. A total of 630 (54.2%) and 574 (49.4%) patients had DRA diameter < 2.3 mm in the right and left hands, respectively. Female sex, low body mass index (BMI), and low body surface area (BSA) were significant predictors of DRA diameter < 2.3 mm. CONCLUSIONS: We provided reference DRA diameters for Korean patients. Approximately 50% of the studied patients had DRA diameter < 2.3 mm. Female sex, low BMI, and low BSA remained significant predictors of DRA diameter < 2.3 mm. The Korean Association of Internal Medicine 2022-01 2021-12-29 /pmc/articles/PMC8747912/ /pubmed/35000375 http://dx.doi.org/10.3904/kjim.2020.685 Text en Copyright © 2022 The Korean Association of Internal Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Jun-Won Son, Jung-Woo Go, Tae-Hwa Kang, Dae Ryong Lee, Sang Jun Kim, Se Eun Cho, Dong-Hyuk Park, Young Jun Youn, Young Jin Ahn, Min-Soo Ahn, Sung Gyun Kim, Jang-Young Yoo, Byung-Su Yoon, Junghan Lee, Seung-Hwan Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment |
title | Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment |
title_full | Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment |
title_fullStr | Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment |
title_full_unstemmed | Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment |
title_short | Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment |
title_sort | reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747912/ https://www.ncbi.nlm.nih.gov/pubmed/35000375 http://dx.doi.org/10.3904/kjim.2020.685 |
work_keys_str_mv | AT leejunwon referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT sonjungwoo referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT gotaehwa referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT kangdaeryong referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT leesangjun referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT kimseeun referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT chodonghyuk referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT parkyoungjun referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT younyoungjin referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT ahnminsoo referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT ahnsunggyun referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT kimjangyoung referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT yoobyungsu referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT yoonjunghan referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment AT leeseunghwan referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment |