Cargando…

Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment

BACKGROUND/AIMS: While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to determine the DRA reference diameters of Korean patients and identify the predictors of DRA diameter < 2.3 mm....

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jun-Won, Son, Jung-Woo, Go, Tae-Hwa, Kang, Dae Ryong, Lee, Sang Jun, Kim, Se Eun, Cho, Dong-Hyuk, Park, Young Jun, Youn, Young Jin, Ahn, Min-Soo, Ahn, Sung Gyun, Kim, Jang-Young, Yoo, Byung-Su, Yoon, Junghan, Lee, Seung-Hwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Association of Internal Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747912/
https://www.ncbi.nlm.nih.gov/pubmed/35000375
http://dx.doi.org/10.3904/kjim.2020.685
_version_ 1784630944631619584
author Lee, Jun-Won
Son, Jung-Woo
Go, Tae-Hwa
Kang, Dae Ryong
Lee, Sang Jun
Kim, Se Eun
Cho, Dong-Hyuk
Park, Young Jun
Youn, Young Jin
Ahn, Min-Soo
Ahn, Sung Gyun
Kim, Jang-Young
Yoo, Byung-Su
Yoon, Junghan
Lee, Seung-Hwan
author_facet Lee, Jun-Won
Son, Jung-Woo
Go, Tae-Hwa
Kang, Dae Ryong
Lee, Sang Jun
Kim, Se Eun
Cho, Dong-Hyuk
Park, Young Jun
Youn, Young Jin
Ahn, Min-Soo
Ahn, Sung Gyun
Kim, Jang-Young
Yoo, Byung-Su
Yoon, Junghan
Lee, Seung-Hwan
author_sort Lee, Jun-Won
collection PubMed
description BACKGROUND/AIMS: While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to determine the DRA reference diameters of Korean patients and identify the predictors of DRA diameter < 2.3 mm. METHODS: The outer bilateral DRA diameters were assessed using a linear ultrasound probe in 1,162 consecutive patients who underwent transthoracic echocardiography. The DRA diameter was measured by the perpendicular angle in the dorsum of the hand, and the average values were compared by sex. DRA diameter < 2.3 mm was defined as unsuitable for routine diagnostic coronary angiography using a 5 Fr introducer sheath. RESULTS: The mean DRA diameters were 2.31 ± 0.43 mm (right) and 2.35 ± 0.45 mm (left). The DRA was smaller in women than men (right: 2.15 ± 0.38 mm vs. 2.43 ± 0.44 mm, p < 0.001; left: 2.18 ± 0.39 mm vs. 2.47 ± 0.45 mm, p < 0.001). The DRA diameter was approximately 20% smaller than the radial artery diameter. A total of 630 (54.2%) and 574 (49.4%) patients had DRA diameter < 2.3 mm in the right and left hands, respectively. Female sex, low body mass index (BMI), and low body surface area (BSA) were significant predictors of DRA diameter < 2.3 mm. CONCLUSIONS: We provided reference DRA diameters for Korean patients. Approximately 50% of the studied patients had DRA diameter < 2.3 mm. Female sex, low BMI, and low BSA remained significant predictors of DRA diameter < 2.3 mm.
format Online
Article
Text
id pubmed-8747912
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Korean Association of Internal Medicine
record_format MEDLINE/PubMed
spelling pubmed-87479122022-01-18 Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment Lee, Jun-Won Son, Jung-Woo Go, Tae-Hwa Kang, Dae Ryong Lee, Sang Jun Kim, Se Eun Cho, Dong-Hyuk Park, Young Jun Youn, Young Jin Ahn, Min-Soo Ahn, Sung Gyun Kim, Jang-Young Yoo, Byung-Su Yoon, Junghan Lee, Seung-Hwan Korean J Intern Med Original Article BACKGROUND/AIMS: While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to determine the DRA reference diameters of Korean patients and identify the predictors of DRA diameter < 2.3 mm. METHODS: The outer bilateral DRA diameters were assessed using a linear ultrasound probe in 1,162 consecutive patients who underwent transthoracic echocardiography. The DRA diameter was measured by the perpendicular angle in the dorsum of the hand, and the average values were compared by sex. DRA diameter < 2.3 mm was defined as unsuitable for routine diagnostic coronary angiography using a 5 Fr introducer sheath. RESULTS: The mean DRA diameters were 2.31 ± 0.43 mm (right) and 2.35 ± 0.45 mm (left). The DRA was smaller in women than men (right: 2.15 ± 0.38 mm vs. 2.43 ± 0.44 mm, p < 0.001; left: 2.18 ± 0.39 mm vs. 2.47 ± 0.45 mm, p < 0.001). The DRA diameter was approximately 20% smaller than the radial artery diameter. A total of 630 (54.2%) and 574 (49.4%) patients had DRA diameter < 2.3 mm in the right and left hands, respectively. Female sex, low body mass index (BMI), and low body surface area (BSA) were significant predictors of DRA diameter < 2.3 mm. CONCLUSIONS: We provided reference DRA diameters for Korean patients. Approximately 50% of the studied patients had DRA diameter < 2.3 mm. Female sex, low BMI, and low BSA remained significant predictors of DRA diameter < 2.3 mm. The Korean Association of Internal Medicine 2022-01 2021-12-29 /pmc/articles/PMC8747912/ /pubmed/35000375 http://dx.doi.org/10.3904/kjim.2020.685 Text en Copyright © 2022 The Korean Association of Internal Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Jun-Won
Son, Jung-Woo
Go, Tae-Hwa
Kang, Dae Ryong
Lee, Sang Jun
Kim, Se Eun
Cho, Dong-Hyuk
Park, Young Jun
Youn, Young Jin
Ahn, Min-Soo
Ahn, Sung Gyun
Kim, Jang-Young
Yoo, Byung-Su
Yoon, Junghan
Lee, Seung-Hwan
Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment
title Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment
title_full Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment
title_fullStr Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment
title_full_unstemmed Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment
title_short Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment
title_sort reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747912/
https://www.ncbi.nlm.nih.gov/pubmed/35000375
http://dx.doi.org/10.3904/kjim.2020.685
work_keys_str_mv AT leejunwon referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT sonjungwoo referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT gotaehwa referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT kangdaeryong referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT leesangjun referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT kimseeun referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT chodonghyuk referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT parkyoungjun referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT younyoungjin referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT ahnminsoo referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT ahnsunggyun referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT kimjangyoung referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT yoobyungsu referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT yoonjunghan referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment
AT leeseunghwan referencediameterandcharacteristicsofthedistalradialarterybasedonultrasonographicassessment