Cargando…

Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries

To elucidate the accuracy, efficacy, and safety of percutaneous iliosacral screw (ISS) and trans-iliac trans-sacral screw (TITS) insertion using a single C-arm fluoroscopy intensifier. Additionally, the potential risk factors that might cause mal-positioned screws were identified. Patients with pelv...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jui-Ping, Tsai, Ping-Jui, Su, Chun-Yi, Tseng, I.-Chuan, Chou, Ying-Chao, Chen, I.-Jung, Lee, Pai-Wei, Yu, Yi-Hsun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8748721/
https://www.ncbi.nlm.nih.gov/pubmed/35013494
http://dx.doi.org/10.1038/s41598-021-04351-z
_version_ 1784631066512850944
author Chen, Jui-Ping
Tsai, Ping-Jui
Su, Chun-Yi
Tseng, I.-Chuan
Chou, Ying-Chao
Chen, I.-Jung
Lee, Pai-Wei
Yu, Yi-Hsun
author_facet Chen, Jui-Ping
Tsai, Ping-Jui
Su, Chun-Yi
Tseng, I.-Chuan
Chou, Ying-Chao
Chen, I.-Jung
Lee, Pai-Wei
Yu, Yi-Hsun
author_sort Chen, Jui-Ping
collection PubMed
description To elucidate the accuracy, efficacy, and safety of percutaneous iliosacral screw (ISS) and trans-iliac trans-sacral screw (TITS) insertion using a single C-arm fluoroscopy intensifier. Additionally, the potential risk factors that might cause mal-positioned screws were identified. Patients with pelvic ring injuries who underwent percutaneous screw fixation in a single medical institute were divided into an ISS group (n = 59) and a TITS group (n = 62) and assessed. The angles deviated from ideal orientation (ADIO) of the implanted screw were measured, and potential risk factors for mal-positioned screws were analyzed. Overall, the reduction quality of the pelvic ring was good or excellent in 70 patients (82.4%) by Matta’s criteria and in 48 patients (56.5%) by Lefaivre’s criteria. ADIO measurements of the ISS and TITS groups via multi-planar computed tomography were 9.16° ± 6.97° and 3.09° ± 2.8° in the axial view, respectively, and 5.92° ± 3.65° and 2.10° ± 2.01° in the coronal view, respectively. Univariate statistical analysis revealed body mass index as the single potential risk factor of mal-positioned screws. With careful preoperative planning and intraoperative preparations, placing ISS and TITS under the guidance of single C-arm fluoroscopy intensifier is a reliable and safe technique. Caution should be exercised when performing this procedure in patients with a high body mass index.
format Online
Article
Text
id pubmed-8748721
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-87487212022-01-11 Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries Chen, Jui-Ping Tsai, Ping-Jui Su, Chun-Yi Tseng, I.-Chuan Chou, Ying-Chao Chen, I.-Jung Lee, Pai-Wei Yu, Yi-Hsun Sci Rep Article To elucidate the accuracy, efficacy, and safety of percutaneous iliosacral screw (ISS) and trans-iliac trans-sacral screw (TITS) insertion using a single C-arm fluoroscopy intensifier. Additionally, the potential risk factors that might cause mal-positioned screws were identified. Patients with pelvic ring injuries who underwent percutaneous screw fixation in a single medical institute were divided into an ISS group (n = 59) and a TITS group (n = 62) and assessed. The angles deviated from ideal orientation (ADIO) of the implanted screw were measured, and potential risk factors for mal-positioned screws were analyzed. Overall, the reduction quality of the pelvic ring was good or excellent in 70 patients (82.4%) by Matta’s criteria and in 48 patients (56.5%) by Lefaivre’s criteria. ADIO measurements of the ISS and TITS groups via multi-planar computed tomography were 9.16° ± 6.97° and 3.09° ± 2.8° in the axial view, respectively, and 5.92° ± 3.65° and 2.10° ± 2.01° in the coronal view, respectively. Univariate statistical analysis revealed body mass index as the single potential risk factor of mal-positioned screws. With careful preoperative planning and intraoperative preparations, placing ISS and TITS under the guidance of single C-arm fluoroscopy intensifier is a reliable and safe technique. Caution should be exercised when performing this procedure in patients with a high body mass index. Nature Publishing Group UK 2022-01-10 /pmc/articles/PMC8748721/ /pubmed/35013494 http://dx.doi.org/10.1038/s41598-021-04351-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Chen, Jui-Ping
Tsai, Ping-Jui
Su, Chun-Yi
Tseng, I.-Chuan
Chou, Ying-Chao
Chen, I.-Jung
Lee, Pai-Wei
Yu, Yi-Hsun
Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries
title Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries
title_full Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries
title_fullStr Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries
title_full_unstemmed Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries
title_short Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries
title_sort percutaneous iliosacral screw and trans-iliac trans-sacral screw with single c-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8748721/
https://www.ncbi.nlm.nih.gov/pubmed/35013494
http://dx.doi.org/10.1038/s41598-021-04351-z
work_keys_str_mv AT chenjuiping percutaneousiliosacralscrewandtransiliactranssacralscrewwithsinglecarmfluoroscopeintensifierisasafetreatmentforpelvicringinjuries
AT tsaipingjui percutaneousiliosacralscrewandtransiliactranssacralscrewwithsinglecarmfluoroscopeintensifierisasafetreatmentforpelvicringinjuries
AT suchunyi percutaneousiliosacralscrewandtransiliactranssacralscrewwithsinglecarmfluoroscopeintensifierisasafetreatmentforpelvicringinjuries
AT tsengichuan percutaneousiliosacralscrewandtransiliactranssacralscrewwithsinglecarmfluoroscopeintensifierisasafetreatmentforpelvicringinjuries
AT chouyingchao percutaneousiliosacralscrewandtransiliactranssacralscrewwithsinglecarmfluoroscopeintensifierisasafetreatmentforpelvicringinjuries
AT chenijung percutaneousiliosacralscrewandtransiliactranssacralscrewwithsinglecarmfluoroscopeintensifierisasafetreatmentforpelvicringinjuries
AT leepaiwei percutaneousiliosacralscrewandtransiliactranssacralscrewwithsinglecarmfluoroscopeintensifierisasafetreatmentforpelvicringinjuries
AT yuyihsun percutaneousiliosacralscrewandtransiliactranssacralscrewwithsinglecarmfluoroscopeintensifierisasafetreatmentforpelvicringinjuries