Cargando…
Measurement of effective renal plasma flow using model analysis of dynamic CT in the preoperative evaluation of the renal transplant donors
OBJECTIVES: Renal scintigraphy is widely used to evaluate residual function of a transplanted kidney from the donor. Dynamic computed tomography (CT) imaging can evaluate both kidney morphology and regional renal function. The aim of this study was to develop an imaging protocol and a calculation me...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Fujita Medical Society
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8749505/ https://www.ncbi.nlm.nih.gov/pubmed/35111525 http://dx.doi.org/10.20407/fmj.2018-017 |
_version_ | 1784631245188104192 |
---|---|
author | Kataoka, Yumi Nishio, Hitoshi Matsukiyo, Ryo Kato, Ryoichi Hasegawa, Midori Kenmochi, Takashi Shiroki, Ryoichi Toyama, Hiroshi Ichihara, Takashi Kobayashi, Shigeki |
author_facet | Kataoka, Yumi Nishio, Hitoshi Matsukiyo, Ryo Kato, Ryoichi Hasegawa, Midori Kenmochi, Takashi Shiroki, Ryoichi Toyama, Hiroshi Ichihara, Takashi Kobayashi, Shigeki |
author_sort | Kataoka, Yumi |
collection | PubMed |
description | OBJECTIVES: Renal scintigraphy is widely used to evaluate residual function of a transplanted kidney from the donor. Dynamic computed tomography (CT) imaging can evaluate both kidney morphology and regional renal function. The aim of this study was to develop an imaging protocol and a calculation method using dynamic CT for assessing the effective renal plasma flow (ERPF) by model analysis, and to evaluate the validity of the obtained ERPF values. METHODS: Preoperative dynamic CT examination with a low radiation dose exposure system was performed for 25 renal transplant donors, and ERPF was calculated from the obtained images (CT-ERPF). To calculate CT-ERPF, we set the region of interest (ROI) in the renal cortex using automatic ROI-setting software developed in our laboratory. We compared the processing time with automatic and manual ROI settings. To evaluate the validity of CT-ERPF, we examined the correlation of age with CT-ERPF and compared with reported ERPF values. We also compared the uptake rates of technetium-99m-dimercaptosuccinic acid and CT-ERPF in terms of the right-to-left ratio. RESULTS: There was good agreement of CT-ERPF assessed using automatic and manual ROIs. CT-ERPF was negatively correlated with age and showed values below the reference ERPF range in 21 cases. The right-to-left ratio of CT-ERPF showed a significant correlation with that of technetium-99m-dimercaptosuccinic acid. CONCLUSIONS: Using our method, CT-ERPF was a useful indicator for preoperative evaluation of donor’s renal function. |
format | Online Article Text |
id | pubmed-8749505 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Fujita Medical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-87495052022-02-01 Measurement of effective renal plasma flow using model analysis of dynamic CT in the preoperative evaluation of the renal transplant donors Kataoka, Yumi Nishio, Hitoshi Matsukiyo, Ryo Kato, Ryoichi Hasegawa, Midori Kenmochi, Takashi Shiroki, Ryoichi Toyama, Hiroshi Ichihara, Takashi Kobayashi, Shigeki Fujita Med J Original Article OBJECTIVES: Renal scintigraphy is widely used to evaluate residual function of a transplanted kidney from the donor. Dynamic computed tomography (CT) imaging can evaluate both kidney morphology and regional renal function. The aim of this study was to develop an imaging protocol and a calculation method using dynamic CT for assessing the effective renal plasma flow (ERPF) by model analysis, and to evaluate the validity of the obtained ERPF values. METHODS: Preoperative dynamic CT examination with a low radiation dose exposure system was performed for 25 renal transplant donors, and ERPF was calculated from the obtained images (CT-ERPF). To calculate CT-ERPF, we set the region of interest (ROI) in the renal cortex using automatic ROI-setting software developed in our laboratory. We compared the processing time with automatic and manual ROI settings. To evaluate the validity of CT-ERPF, we examined the correlation of age with CT-ERPF and compared with reported ERPF values. We also compared the uptake rates of technetium-99m-dimercaptosuccinic acid and CT-ERPF in terms of the right-to-left ratio. RESULTS: There was good agreement of CT-ERPF assessed using automatic and manual ROIs. CT-ERPF was negatively correlated with age and showed values below the reference ERPF range in 21 cases. The right-to-left ratio of CT-ERPF showed a significant correlation with that of technetium-99m-dimercaptosuccinic acid. CONCLUSIONS: Using our method, CT-ERPF was a useful indicator for preoperative evaluation of donor’s renal function. Fujita Medical Society 2020 2020-02-11 /pmc/articles/PMC8749505/ /pubmed/35111525 http://dx.doi.org/10.20407/fmj.2018-017 Text en https://creativecommons.org/licenses/by/4.0/This is an Open access article distributed under the Terms of Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Original Article Kataoka, Yumi Nishio, Hitoshi Matsukiyo, Ryo Kato, Ryoichi Hasegawa, Midori Kenmochi, Takashi Shiroki, Ryoichi Toyama, Hiroshi Ichihara, Takashi Kobayashi, Shigeki Measurement of effective renal plasma flow using model analysis of dynamic CT in the preoperative evaluation of the renal transplant donors |
title | Measurement of effective renal plasma flow using model analysis of
dynamic CT in the preoperative evaluation of the renal transplant donors |
title_full | Measurement of effective renal plasma flow using model analysis of
dynamic CT in the preoperative evaluation of the renal transplant donors |
title_fullStr | Measurement of effective renal plasma flow using model analysis of
dynamic CT in the preoperative evaluation of the renal transplant donors |
title_full_unstemmed | Measurement of effective renal plasma flow using model analysis of
dynamic CT in the preoperative evaluation of the renal transplant donors |
title_short | Measurement of effective renal plasma flow using model analysis of
dynamic CT in the preoperative evaluation of the renal transplant donors |
title_sort | measurement of effective renal plasma flow using model analysis of
dynamic ct in the preoperative evaluation of the renal transplant donors |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8749505/ https://www.ncbi.nlm.nih.gov/pubmed/35111525 http://dx.doi.org/10.20407/fmj.2018-017 |
work_keys_str_mv | AT kataokayumi measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors AT nishiohitoshi measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors AT matsukiyoryo measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors AT katoryoichi measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors AT hasegawamidori measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors AT kenmochitakashi measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors AT shirokiryoichi measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors AT toyamahiroshi measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors AT ichiharatakashi measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors AT kobayashishigeki measurementofeffectiverenalplasmaflowusingmodelanalysisofdynamicctinthepreoperativeevaluationoftherenaltransplantdonors |