Converging Proton Minibeams with Magnetic Fields for Optimized Radiation Therapy: A Proof of Concept
SIMPLE SUMMARY: Healthy tissue tolerance to radiation is one of the main limitations in radiotherapy treatment. To broaden the therapeutic index, innovative approaches using non-conventional spatial and temporal beam structure are currently being investigated. Among them, proton minibeam radiation t...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8750079/ https://www.ncbi.nlm.nih.gov/pubmed/35008189 http://dx.doi.org/10.3390/cancers14010026 |
_version_ | 1784631379375423488 |
---|---|
author | Cavallone, Marco Prezado, Yolanda De Marzi, Ludovic |
author_facet | Cavallone, Marco Prezado, Yolanda De Marzi, Ludovic |
author_sort | Cavallone, Marco |
collection | PubMed |
description | SIMPLE SUMMARY: Healthy tissue tolerance to radiation is one of the main limitations in radiotherapy treatment. To broaden the therapeutic index, innovative approaches using non-conventional spatial and temporal beam structure are currently being investigated. Among them, proton minibeam radiation therapy is a promising solution that has already shown a remarkable increase in healthy tissue tolerance in various preclinical models. The purpose of this study is to propose potential strategies to further optimize proton minibeam spatial modulation with the use of magnetic fields. By generating a converging minibeam pattern with dipole magnetic fields, we show that spatial modulation can be improved at shallow depth for the same dose distribution at the tumor location. This indicates that proton minibeam radiation therapy could be efficiently combined with magnetic fields to further increase healthy tissue tolerance. ABSTRACT: Proton MiniBeam Radiation Therapy (pMBRT) is a novel strategy that combines the benefits of minibeam radiation therapy with the more precise ballistics of protons to further optimize the dose distribution and reduce radiation side effects. The aim of this study is to investigate possible strategies to couple pMBRT with dipole magnetic fields to generate a converging minibeam pattern and increase the center-to-center distance between minibeams. Magnetic field optimization was performed so as to obtain the same transverse dose profile at the Bragg peak position as in a reference configuration with no magnetic field. Monte Carlo simulations reproducing realistic pencil beam scanning settings were used to compute the dose in a water phantom. We analyzed different minibeam generation techniques, such as the use of a static multislit collimator or a dynamic aperture, and different magnetic field positions, i.e., before or within the water phantom. The best results were obtained using a dynamic aperture coupled with a magnetic field within the water phantom. For a center-to-center distance increase from 4 mm to 6 mm, we obtained an increase of peak-to-valley dose ratio and decrease of valley dose above 50%. The results indicate that magnetic fields can be effectively used to improve the spatial modulation at shallow depth for enhanced healthy tissue sparing. |
format | Online Article Text |
id | pubmed-8750079 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87500792022-01-12 Converging Proton Minibeams with Magnetic Fields for Optimized Radiation Therapy: A Proof of Concept Cavallone, Marco Prezado, Yolanda De Marzi, Ludovic Cancers (Basel) Article SIMPLE SUMMARY: Healthy tissue tolerance to radiation is one of the main limitations in radiotherapy treatment. To broaden the therapeutic index, innovative approaches using non-conventional spatial and temporal beam structure are currently being investigated. Among them, proton minibeam radiation therapy is a promising solution that has already shown a remarkable increase in healthy tissue tolerance in various preclinical models. The purpose of this study is to propose potential strategies to further optimize proton minibeam spatial modulation with the use of magnetic fields. By generating a converging minibeam pattern with dipole magnetic fields, we show that spatial modulation can be improved at shallow depth for the same dose distribution at the tumor location. This indicates that proton minibeam radiation therapy could be efficiently combined with magnetic fields to further increase healthy tissue tolerance. ABSTRACT: Proton MiniBeam Radiation Therapy (pMBRT) is a novel strategy that combines the benefits of minibeam radiation therapy with the more precise ballistics of protons to further optimize the dose distribution and reduce radiation side effects. The aim of this study is to investigate possible strategies to couple pMBRT with dipole magnetic fields to generate a converging minibeam pattern and increase the center-to-center distance between minibeams. Magnetic field optimization was performed so as to obtain the same transverse dose profile at the Bragg peak position as in a reference configuration with no magnetic field. Monte Carlo simulations reproducing realistic pencil beam scanning settings were used to compute the dose in a water phantom. We analyzed different minibeam generation techniques, such as the use of a static multislit collimator or a dynamic aperture, and different magnetic field positions, i.e., before or within the water phantom. The best results were obtained using a dynamic aperture coupled with a magnetic field within the water phantom. For a center-to-center distance increase from 4 mm to 6 mm, we obtained an increase of peak-to-valley dose ratio and decrease of valley dose above 50%. The results indicate that magnetic fields can be effectively used to improve the spatial modulation at shallow depth for enhanced healthy tissue sparing. MDPI 2021-12-22 /pmc/articles/PMC8750079/ /pubmed/35008189 http://dx.doi.org/10.3390/cancers14010026 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Cavallone, Marco Prezado, Yolanda De Marzi, Ludovic Converging Proton Minibeams with Magnetic Fields for Optimized Radiation Therapy: A Proof of Concept |
title | Converging Proton Minibeams with Magnetic Fields for Optimized Radiation Therapy: A Proof of Concept |
title_full | Converging Proton Minibeams with Magnetic Fields for Optimized Radiation Therapy: A Proof of Concept |
title_fullStr | Converging Proton Minibeams with Magnetic Fields for Optimized Radiation Therapy: A Proof of Concept |
title_full_unstemmed | Converging Proton Minibeams with Magnetic Fields for Optimized Radiation Therapy: A Proof of Concept |
title_short | Converging Proton Minibeams with Magnetic Fields for Optimized Radiation Therapy: A Proof of Concept |
title_sort | converging proton minibeams with magnetic fields for optimized radiation therapy: a proof of concept |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8750079/ https://www.ncbi.nlm.nih.gov/pubmed/35008189 http://dx.doi.org/10.3390/cancers14010026 |
work_keys_str_mv | AT cavallonemarco convergingprotonminibeamswithmagneticfieldsforoptimizedradiationtherapyaproofofconcept AT prezadoyolanda convergingprotonminibeamswithmagneticfieldsforoptimizedradiationtherapyaproofofconcept AT demarziludovic convergingprotonminibeamswithmagneticfieldsforoptimizedradiationtherapyaproofofconcept |