Cargando…
An International, Multicenter Retrospective Observational Study to Assess Technical Success and Clinical Outcomes of Patients Treated with an Endovascular Aneurysm Sealing Device for Type III Endoleak
INTRODUCTION: Type III endoleaks post-endovascular aortic aneurysm repair (EVAR) warrant treatment because they increase pressure within the aneurysm sac leading to increased rupture risk. The treatment may be difficult with regular endovascular devices. Endovascular aneurysm sealing (EVAS) might pr...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8750149/ https://www.ncbi.nlm.nih.gov/pubmed/34342235 http://dx.doi.org/10.1177/15266028211031933 |
_version_ | 1784631395382984704 |
---|---|
author | Zoethout, Aleksandra C. Ketting, Shirley Zeebregts, Clark J. Apostolou, Dimitri Mees, Barend M.E. Berg, Patrick Beyrouti, Hazem El De Vries, Jean-Paul P.M. Torella, Francesco Migliari, Mattia Silingardi, Roberto Reijnen, Michel M.P.J. |
author_facet | Zoethout, Aleksandra C. Ketting, Shirley Zeebregts, Clark J. Apostolou, Dimitri Mees, Barend M.E. Berg, Patrick Beyrouti, Hazem El De Vries, Jean-Paul P.M. Torella, Francesco Migliari, Mattia Silingardi, Roberto Reijnen, Michel M.P.J. |
author_sort | Zoethout, Aleksandra C. |
collection | PubMed |
description | INTRODUCTION: Type III endoleaks post-endovascular aortic aneurysm repair (EVAR) warrant treatment because they increase pressure within the aneurysm sac leading to increased rupture risk. The treatment may be difficult with regular endovascular devices. Endovascular aneurysm sealing (EVAS) might provide a treatment option for type III endoleaks, especially if located near the flow divider. This study aims to analyze clinical outcomes of EVAS for type III endoleaks after EVAR. METHODS: This is an international, retrospective, observational cohort study including data from 8 European institutions. RESULTS: A total of 20 patients were identified of which 80% had a type IIIb endoleak and the remainder (20%) a type IIIa endoleak. The median time between EVAR and EVAS was 49.5 months (28.5–89). Mean AAA diameter prior to EVAS revision was 76.6±19.9 mm. Technical success was achieved in 95%, 1 patient had technical failure due to a postoperative myocardial infarction resulting in death. Mean follow-up was 22.8±15.2 months. During follow-up 1 patient had a type Ia endoleak, and 1 patient had a new type IIIa endoleak at an untreated location. There were 5 patients with aneurysm growth. Five patients underwent AAA-related reinterventions indications being: growth with type II endoleak (n=3), type Ia endoleak (n=1), and iliac aneurysm (n=1). At 1-year follow-up, the freedom from clinical failure was 77.5%, freedom from all-cause mortality 94.7%, freedom from aneurysm-related mortality 95%, and freedom from aneurysm-related reinterventions 93.8%. CONCLUSION: The EVAS relining can be safely performed to treat type III endoleaks with an acceptable technical success rate, a low 30-day mortality rate and no secondary ruptures at short-term follow-up. The relatively low clinical success rates, related to reinterventions and AAA enlargement, highlight the need for prolonged follow-up. |
format | Online Article Text |
id | pubmed-8750149 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-87501492022-01-12 An International, Multicenter Retrospective Observational Study to Assess Technical Success and Clinical Outcomes of Patients Treated with an Endovascular Aneurysm Sealing Device for Type III Endoleak Zoethout, Aleksandra C. Ketting, Shirley Zeebregts, Clark J. Apostolou, Dimitri Mees, Barend M.E. Berg, Patrick Beyrouti, Hazem El De Vries, Jean-Paul P.M. Torella, Francesco Migliari, Mattia Silingardi, Roberto Reijnen, Michel M.P.J. J Endovasc Ther Clinical Investigations INTRODUCTION: Type III endoleaks post-endovascular aortic aneurysm repair (EVAR) warrant treatment because they increase pressure within the aneurysm sac leading to increased rupture risk. The treatment may be difficult with regular endovascular devices. Endovascular aneurysm sealing (EVAS) might provide a treatment option for type III endoleaks, especially if located near the flow divider. This study aims to analyze clinical outcomes of EVAS for type III endoleaks after EVAR. METHODS: This is an international, retrospective, observational cohort study including data from 8 European institutions. RESULTS: A total of 20 patients were identified of which 80% had a type IIIb endoleak and the remainder (20%) a type IIIa endoleak. The median time between EVAR and EVAS was 49.5 months (28.5–89). Mean AAA diameter prior to EVAS revision was 76.6±19.9 mm. Technical success was achieved in 95%, 1 patient had technical failure due to a postoperative myocardial infarction resulting in death. Mean follow-up was 22.8±15.2 months. During follow-up 1 patient had a type Ia endoleak, and 1 patient had a new type IIIa endoleak at an untreated location. There were 5 patients with aneurysm growth. Five patients underwent AAA-related reinterventions indications being: growth with type II endoleak (n=3), type Ia endoleak (n=1), and iliac aneurysm (n=1). At 1-year follow-up, the freedom from clinical failure was 77.5%, freedom from all-cause mortality 94.7%, freedom from aneurysm-related mortality 95%, and freedom from aneurysm-related reinterventions 93.8%. CONCLUSION: The EVAS relining can be safely performed to treat type III endoleaks with an acceptable technical success rate, a low 30-day mortality rate and no secondary ruptures at short-term follow-up. The relatively low clinical success rates, related to reinterventions and AAA enlargement, highlight the need for prolonged follow-up. SAGE Publications 2021-08-03 2022-02 /pmc/articles/PMC8750149/ /pubmed/34342235 http://dx.doi.org/10.1177/15266028211031933 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Clinical Investigations Zoethout, Aleksandra C. Ketting, Shirley Zeebregts, Clark J. Apostolou, Dimitri Mees, Barend M.E. Berg, Patrick Beyrouti, Hazem El De Vries, Jean-Paul P.M. Torella, Francesco Migliari, Mattia Silingardi, Roberto Reijnen, Michel M.P.J. An International, Multicenter Retrospective Observational Study to Assess Technical Success and Clinical Outcomes of Patients Treated with an Endovascular Aneurysm Sealing Device for Type III Endoleak |
title | An International, Multicenter Retrospective Observational Study to
Assess Technical Success and Clinical Outcomes of Patients Treated with an
Endovascular Aneurysm Sealing Device for Type III Endoleak |
title_full | An International, Multicenter Retrospective Observational Study to
Assess Technical Success and Clinical Outcomes of Patients Treated with an
Endovascular Aneurysm Sealing Device for Type III Endoleak |
title_fullStr | An International, Multicenter Retrospective Observational Study to
Assess Technical Success and Clinical Outcomes of Patients Treated with an
Endovascular Aneurysm Sealing Device for Type III Endoleak |
title_full_unstemmed | An International, Multicenter Retrospective Observational Study to
Assess Technical Success and Clinical Outcomes of Patients Treated with an
Endovascular Aneurysm Sealing Device for Type III Endoleak |
title_short | An International, Multicenter Retrospective Observational Study to
Assess Technical Success and Clinical Outcomes of Patients Treated with an
Endovascular Aneurysm Sealing Device for Type III Endoleak |
title_sort | international, multicenter retrospective observational study to
assess technical success and clinical outcomes of patients treated with an
endovascular aneurysm sealing device for type iii endoleak |
topic | Clinical Investigations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8750149/ https://www.ncbi.nlm.nih.gov/pubmed/34342235 http://dx.doi.org/10.1177/15266028211031933 |
work_keys_str_mv | AT zoethoutaleksandrac aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT kettingshirley aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT zeebregtsclarkj aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT apostoloudimitri aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT meesbarendme aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT bergpatrick aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT beyroutihazemel aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT devriesjeanpaulpm aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT torellafrancesco aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT migliarimattia aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT silingardiroberto aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT reijnenmichelmpj aninternationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT zoethoutaleksandrac internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT kettingshirley internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT zeebregtsclarkj internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT apostoloudimitri internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT meesbarendme internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT bergpatrick internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT beyroutihazemel internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT devriesjeanpaulpm internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT torellafrancesco internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT migliarimattia internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT silingardiroberto internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak AT reijnenmichelmpj internationalmulticenterretrospectiveobservationalstudytoassesstechnicalsuccessandclinicaloutcomesofpatientstreatedwithanendovascularaneurysmsealingdevicefortypeiiiendoleak |