Cargando…

Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation

BACKGROUND: Early generation drug‐eluting stents (DESs) showed a high grade of coronary endothelial dysfunction that was attributed to lack of stent reendothelialization. Endothelium‐dependent vasomotor response of current DESs and bioresorbable scaffolds (BRSs) remains unknown. This study sought to...

Descripción completa

Detalles Bibliográficos
Autores principales: Gomez‐Lara, Josep, Oyarzabal, Loreto, Ortega‐Paz, Luis, Brugaletta, Salvatore, Romaguera, Rafael, Salvatella, Neus, Roura, Gerard, Rivero, Fernando, Fuentes, Lara, Alfonso, Fernando, Otaegui, Imanol, Vandeloo, Bert, Vaquerizo, Beatriz, Sabate, Manel, Comin‐Colet, Josep, Gomez‐Hospital, Joan‐Antoni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8751934/
https://www.ncbi.nlm.nih.gov/pubmed/34729992
http://dx.doi.org/10.1161/JAHA.121.022123
_version_ 1784631785375662080
author Gomez‐Lara, Josep
Oyarzabal, Loreto
Ortega‐Paz, Luis
Brugaletta, Salvatore
Romaguera, Rafael
Salvatella, Neus
Roura, Gerard
Rivero, Fernando
Fuentes, Lara
Alfonso, Fernando
Otaegui, Imanol
Vandeloo, Bert
Vaquerizo, Beatriz
Sabate, Manel
Comin‐Colet, Josep
Gomez‐Hospital, Joan‐Antoni
author_facet Gomez‐Lara, Josep
Oyarzabal, Loreto
Ortega‐Paz, Luis
Brugaletta, Salvatore
Romaguera, Rafael
Salvatella, Neus
Roura, Gerard
Rivero, Fernando
Fuentes, Lara
Alfonso, Fernando
Otaegui, Imanol
Vandeloo, Bert
Vaquerizo, Beatriz
Sabate, Manel
Comin‐Colet, Josep
Gomez‐Hospital, Joan‐Antoni
author_sort Gomez‐Lara, Josep
collection PubMed
description BACKGROUND: Early generation drug‐eluting stents (DESs) showed a high grade of coronary endothelial dysfunction that was attributed to lack of stent reendothelialization. Endothelium‐dependent vasomotor response of current DESs and bioresorbable scaffolds (BRSs) remains unknown. This study sought to assess the device‐related endothelial function of current devices and to correlate neointima healing with endothelial function. METHODS AND RESULTS: A total of 206 patients from 4 randomized trials treated with the durable‐polymer everolimus‐eluting Xience (n=44), bioresorbable‐polymer sirolimus‐eluting Orsiro (n=35), polymer‐free biolimus‐eluting Biofreedom (n=24), bioactive endothelial‐progenitor cell‐capturing sirolimus‐eluting Combo DES (n=25), polymer‐based everolimus‐eluting Absorb (n=44), and Mg‐based sirolimus‐eluting Magmaris BRS (n=34) underwent endothelium‐dependent vasomotor tests and optical coherence tomography imaging, as per protocol, at follow‐up. Crude vasomotor responses of distal segments to low‐dose acetylcholine (10(−6) mol/L) were different between groups: bioresorbablepolymer DEShad the worst (−8.4%±12.6%) and durable‐polymer DES had the most physiologic (−0.4%±11.8%; P=0.014). High‐dose acetylcholine (10(−4) mol/L) showed similar responses between groups (ranging from −10.8%±11.6% to −18.1%±15.4%; P=0.229). Device healing was different between devices. Uncovered struts ranged from 6.3%±7.1% (bioresorbable‐polymer DES) to 2.5%±4.5% (bioactive DES; P=0.056). In multivariate models, endothelium‐dependent vasomotor response was associated with age, bioresorbable‐polymer DES, and angiographic lumen loss, but not with strut coverage nor plaque type. Endothelial dysfunction (defined as ≥4% vasoconstriction) was observed in 46.6% of patients with low‐dose and 68.9% with high‐dose acetylcholine, without differences between groups. CONCLUSIONS: At follow‐up, endothelial dysfunction was frequently observed in distal segments treated with current stents without remarkable differences between devices. Although neointima healing was different between devices, poor healing was not associated with endothelial dysfunction.
format Online
Article
Text
id pubmed-8751934
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-87519342022-01-14 Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation Gomez‐Lara, Josep Oyarzabal, Loreto Ortega‐Paz, Luis Brugaletta, Salvatore Romaguera, Rafael Salvatella, Neus Roura, Gerard Rivero, Fernando Fuentes, Lara Alfonso, Fernando Otaegui, Imanol Vandeloo, Bert Vaquerizo, Beatriz Sabate, Manel Comin‐Colet, Josep Gomez‐Hospital, Joan‐Antoni J Am Heart Assoc Original Research BACKGROUND: Early generation drug‐eluting stents (DESs) showed a high grade of coronary endothelial dysfunction that was attributed to lack of stent reendothelialization. Endothelium‐dependent vasomotor response of current DESs and bioresorbable scaffolds (BRSs) remains unknown. This study sought to assess the device‐related endothelial function of current devices and to correlate neointima healing with endothelial function. METHODS AND RESULTS: A total of 206 patients from 4 randomized trials treated with the durable‐polymer everolimus‐eluting Xience (n=44), bioresorbable‐polymer sirolimus‐eluting Orsiro (n=35), polymer‐free biolimus‐eluting Biofreedom (n=24), bioactive endothelial‐progenitor cell‐capturing sirolimus‐eluting Combo DES (n=25), polymer‐based everolimus‐eluting Absorb (n=44), and Mg‐based sirolimus‐eluting Magmaris BRS (n=34) underwent endothelium‐dependent vasomotor tests and optical coherence tomography imaging, as per protocol, at follow‐up. Crude vasomotor responses of distal segments to low‐dose acetylcholine (10(−6) mol/L) were different between groups: bioresorbablepolymer DEShad the worst (−8.4%±12.6%) and durable‐polymer DES had the most physiologic (−0.4%±11.8%; P=0.014). High‐dose acetylcholine (10(−4) mol/L) showed similar responses between groups (ranging from −10.8%±11.6% to −18.1%±15.4%; P=0.229). Device healing was different between devices. Uncovered struts ranged from 6.3%±7.1% (bioresorbable‐polymer DES) to 2.5%±4.5% (bioactive DES; P=0.056). In multivariate models, endothelium‐dependent vasomotor response was associated with age, bioresorbable‐polymer DES, and angiographic lumen loss, but not with strut coverage nor plaque type. Endothelial dysfunction (defined as ≥4% vasoconstriction) was observed in 46.6% of patients with low‐dose and 68.9% with high‐dose acetylcholine, without differences between groups. CONCLUSIONS: At follow‐up, endothelial dysfunction was frequently observed in distal segments treated with current stents without remarkable differences between devices. Although neointima healing was different between devices, poor healing was not associated with endothelial dysfunction. John Wiley and Sons Inc. 2021-11-03 /pmc/articles/PMC8751934/ /pubmed/34729992 http://dx.doi.org/10.1161/JAHA.121.022123 Text en © 2021 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Research
Gomez‐Lara, Josep
Oyarzabal, Loreto
Ortega‐Paz, Luis
Brugaletta, Salvatore
Romaguera, Rafael
Salvatella, Neus
Roura, Gerard
Rivero, Fernando
Fuentes, Lara
Alfonso, Fernando
Otaegui, Imanol
Vandeloo, Bert
Vaquerizo, Beatriz
Sabate, Manel
Comin‐Colet, Josep
Gomez‐Hospital, Joan‐Antoni
Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation
title Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation
title_full Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation
title_fullStr Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation
title_full_unstemmed Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation
title_short Coronary Endothelium‐Dependent Vasomotor Function After Drug‐Eluting Stent and Bioresorbable Scaffold Implantation
title_sort coronary endothelium‐dependent vasomotor function after drug‐eluting stent and bioresorbable scaffold implantation
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8751934/
https://www.ncbi.nlm.nih.gov/pubmed/34729992
http://dx.doi.org/10.1161/JAHA.121.022123
work_keys_str_mv AT gomezlarajosep coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT oyarzaballoreto coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT ortegapazluis coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT brugalettasalvatore coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT romaguerarafael coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT salvatellaneus coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT rouragerard coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT riverofernando coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT fuenteslara coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT alfonsofernando coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT otaeguiimanol coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT vandeloobert coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT vaquerizobeatriz coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT sabatemanel coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT comincoletjosep coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation
AT gomezhospitaljoanantoni coronaryendotheliumdependentvasomotorfunctionafterdrugelutingstentandbioresorbablescaffoldimplantation