Cargando…

Safety of Occlutech Septal Occluder ACCELL Flex II for Transcatheter Closure of Secundum Atrial Septal Defects in Children: A Long-Term Follow-Up

OBJECTIVES: To assess the long-term safety and efficacy of the Occlutech® ACCELL® Flex II device used for atrial septal defect (ASD) closure. This device differs from the regular device by having two very thin patches that are made of polyethylene terephthalate (PET). These patches enhance faster se...

Descripción completa

Detalles Bibliográficos
Autores principales: El-Sisi, Amal M., El-Saiedi, Sonia A., Ammar, Rasha, Abdelhameed, Asmaa, Hijazi, Ziyad M., Soliman, Mohammed M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8752296/
https://www.ncbi.nlm.nih.gov/pubmed/35069039
http://dx.doi.org/10.1155/2022/8886813
Descripción
Sumario:OBJECTIVES: To assess the long-term safety and efficacy of the Occlutech® ACCELL® Flex II device used for atrial septal defect (ASD) closure. This device differs from the regular device by having two very thin patches that are made of polyethylene terephthalate (PET). These patches enhance faster sealing of the defect. BACKGROUND: Transcatheter closure has become the method of choice to manage most patients with secundum ASDs. There are different types of devices. The regular Occlutech device used to close an ASD is called the Occlutech Figulla Flex II. A newer modification of this device (Occlutech® ACCELL® Flex II) has been designed to eliminate/reduce thrombus formation and to enhance faster sealing. METHODS: Thirty patients were followed up after occlusion of secundum ASD using the Occlutech® ACCELL® Flex II Device. The follow-up period ranged from 5.2–5.5 years with median of 5.3 years. Detailed history and full clinical examination, twelve-lead electrocardiogram (ECG), plain chest radiograph, and full 2D transthoracic echocardiography (TTE) were performed at discharge, at one month, six months, and yearly thereafter. RESULTS: The mean age of the study group at the last follow-up was 10.4 ± 4.6 years, with 63.3% (nineteen patients) females. There were no residual shunts or complications encountered immediately after the procedure and at the latest follow-up. CONCLUSION: This study confirmed the transcatheter closure (TCC) of secundum ASDs using the Occlutech® ACCELL® Flex II device to be safe and effective with no complications detected in children and adolescents.