Cargando…

Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles

The aim of the present in vivo study was to analyze and compare the effects on the crestal bone healing of two different implant macrogeometries installed in fresh socket areas and in normal bone areas with different insertion torque values. Two implant macrogeometries were used in the present study...

Descripción completa

Detalles Bibliográficos
Autores principales: Gehrke, Sergio Alexandre, Júnior, Jaime Aramburú, Treichel, Tiago Luis Eirles, do Prado, Tales Dias, Dedavid, Berenice Anina, de Aza, Piedad N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8752839/
https://www.ncbi.nlm.nih.gov/pubmed/35017552
http://dx.doi.org/10.1038/s41598-021-04313-5
_version_ 1784631961206128640
author Gehrke, Sergio Alexandre
Júnior, Jaime Aramburú
Treichel, Tiago Luis Eirles
do Prado, Tales Dias
Dedavid, Berenice Anina
de Aza, Piedad N.
author_facet Gehrke, Sergio Alexandre
Júnior, Jaime Aramburú
Treichel, Tiago Luis Eirles
do Prado, Tales Dias
Dedavid, Berenice Anina
de Aza, Piedad N.
author_sort Gehrke, Sergio Alexandre
collection PubMed
description The aim of the present in vivo study was to analyze and compare the effects on the crestal bone healing of two different implant macrogeometries installed in fresh socket areas and in normal bone areas with different insertion torque values. Two implant macrogeometries were used in the present study, DuoCone implant (DC) and Maestro implant (MAE), forming four groups: group DCws, in which the implants were installed in healing bone (without a socket); group DCfs, in which the implants were installed in post-extraction areas (fresh sockets); group MAEws, in which the implants were installed in healing bone (without a socket); group MAEfs, in which the implants were installed in post-extraction areas (fresh sockets). After 30 and 90 days of implantations in the bilateral mandibles of 10 sheep, eighty implants were evaluated through digital X-ray images and histologic slices. The crestal bone position in relation to the implant platform shoulder was measured and compared. The measured insertion torque was 47.2 ± 4.69 Ncm for the DCws group, 43.4 ± 4.87 Ncm for the DCfs group, 29.3 ± 3.16 Ncm for the MAEws group, and 27.7 ± 4.41 Ncm for the MAEfs group. The radiographic mesio-distal and histological bucco-lingual analyses showed significantly greater vertical bone loss in the implants installed with high torque (DC groups) in comparison to the implants installed with a low torque (MAE groups) (p < 0.05), at both evaluation times. In general, low insertion torque values (Maestro implants) showed better results of MBL when compared to implants installed with higher torque values (Duo Cone implants). Moreover, our results showed that the implants installed in the sites without sockets showed a less MBL in comparison with the implants installed in sites of fresh sockets.
format Online
Article
Text
id pubmed-8752839
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-87528392022-01-13 Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles Gehrke, Sergio Alexandre Júnior, Jaime Aramburú Treichel, Tiago Luis Eirles do Prado, Tales Dias Dedavid, Berenice Anina de Aza, Piedad N. Sci Rep Article The aim of the present in vivo study was to analyze and compare the effects on the crestal bone healing of two different implant macrogeometries installed in fresh socket areas and in normal bone areas with different insertion torque values. Two implant macrogeometries were used in the present study, DuoCone implant (DC) and Maestro implant (MAE), forming four groups: group DCws, in which the implants were installed in healing bone (without a socket); group DCfs, in which the implants were installed in post-extraction areas (fresh sockets); group MAEws, in which the implants were installed in healing bone (without a socket); group MAEfs, in which the implants were installed in post-extraction areas (fresh sockets). After 30 and 90 days of implantations in the bilateral mandibles of 10 sheep, eighty implants were evaluated through digital X-ray images and histologic slices. The crestal bone position in relation to the implant platform shoulder was measured and compared. The measured insertion torque was 47.2 ± 4.69 Ncm for the DCws group, 43.4 ± 4.87 Ncm for the DCfs group, 29.3 ± 3.16 Ncm for the MAEws group, and 27.7 ± 4.41 Ncm for the MAEfs group. The radiographic mesio-distal and histological bucco-lingual analyses showed significantly greater vertical bone loss in the implants installed with high torque (DC groups) in comparison to the implants installed with a low torque (MAE groups) (p < 0.05), at both evaluation times. In general, low insertion torque values (Maestro implants) showed better results of MBL when compared to implants installed with higher torque values (Duo Cone implants). Moreover, our results showed that the implants installed in the sites without sockets showed a less MBL in comparison with the implants installed in sites of fresh sockets. Nature Publishing Group UK 2022-01-11 /pmc/articles/PMC8752839/ /pubmed/35017552 http://dx.doi.org/10.1038/s41598-021-04313-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Gehrke, Sergio Alexandre
Júnior, Jaime Aramburú
Treichel, Tiago Luis Eirles
do Prado, Tales Dias
Dedavid, Berenice Anina
de Aza, Piedad N.
Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles
title Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles
title_full Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles
title_fullStr Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles
title_full_unstemmed Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles
title_short Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles
title_sort effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8752839/
https://www.ncbi.nlm.nih.gov/pubmed/35017552
http://dx.doi.org/10.1038/s41598-021-04313-5
work_keys_str_mv AT gehrkesergioalexandre effectsofinsertiontorquevaluesonthemarginalbonelossofdentalimplantsinstalledinsheepmandibles
AT juniorjaimearamburu effectsofinsertiontorquevaluesonthemarginalbonelossofdentalimplantsinstalledinsheepmandibles
AT treicheltiagoluiseirles effectsofinsertiontorquevaluesonthemarginalbonelossofdentalimplantsinstalledinsheepmandibles
AT dopradotalesdias effectsofinsertiontorquevaluesonthemarginalbonelossofdentalimplantsinstalledinsheepmandibles
AT dedavidbereniceanina effectsofinsertiontorquevaluesonthemarginalbonelossofdentalimplantsinstalledinsheepmandibles
AT deazapiedadn effectsofinsertiontorquevaluesonthemarginalbonelossofdentalimplantsinstalledinsheepmandibles