Cargando…

Effects of Platelet‐Rich Plasma on Tendon‐Bone Healing After Anterior Cruciate Ligament Reconstruction

OBJECTIVE: To investigate the effect of platelet‐rich plasma on tendon‐bone healing after anterior cruciate ligament reconstruction. METHODS: This retrospective study included 85 patients (range, 18–50 years; mean age, 33.95 ± 10.53 years; male/female, 49/36) who underwent anterior cruciate ligament...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Rong‐jin, Zhu, Hao‐zhong, Gu, Xin‐yi, Xiang, Xian‐xiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8755887/
https://www.ncbi.nlm.nih.gov/pubmed/34870370
http://dx.doi.org/10.1111/os.13175
_version_ 1784632466856738816
author Chen, Rong‐jin
Zhu, Hao‐zhong
Gu, Xin‐yi
Xiang, Xian‐xiang
author_facet Chen, Rong‐jin
Zhu, Hao‐zhong
Gu, Xin‐yi
Xiang, Xian‐xiang
author_sort Chen, Rong‐jin
collection PubMed
description OBJECTIVE: To investigate the effect of platelet‐rich plasma on tendon‐bone healing after anterior cruciate ligament reconstruction. METHODS: This retrospective study included 85 patients (range, 18–50 years; mean age, 33.95 ± 10.53 years; male/female, 49/36) who underwent anterior cruciate ligament reconstruction using autologous hamstring tendons between August 2017 and June 2019 at our institute. The participants in the study group (n = 42) were injected with platelet‐rich plasma at both ends of the tendon graft, while those in the control group (n = 43) received an injection of normal saline. Magnetic resonance imaging signal/noise quotient values of the femoral and tibial ends, knee Lysholm scores, and International Knee Documentation Committee scores were compared at 3, 6, and 12 months postoperatively. RESULTS: The signal/noise quotient values of the femoral and tibial ends in both groups were higher at 6 months than at 3 and 12 months postoperatively. The signal/noise quotient values of the tibial end were significantly lower in the platelet‐rich plasma group than in the normal saline group at all follow‐up time points (P < 0.05). The signal/noise quotient values of the tibial and femoral ends in both groups were significantly different at 3, 6, and 12 months postoperatively (P < 0.05). Additionally, the signal/noise quotient values of the tibia were significantly lower than those of the femur in both groups (P < 0.05). The Lysholm and International Knee Documentation Committee scores were significantly better in the platelet‐rich plasma group than in the normal saline group only at 3 months postoperatively. No complications, such as knee joint infection or vascular and nerve injuries, occurred in any of the 85 patients. The knee flexion of all patients were more than 90°, and the straight degree was 0°. No joint stiffness was observed in all patients. CONCLUSION: Platelet‐rich plasma can promote tendon‐bone healing in grafts and can improve early postoperative knee joint function.
format Online
Article
Text
id pubmed-8755887
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-87558872022-01-19 Effects of Platelet‐Rich Plasma on Tendon‐Bone Healing After Anterior Cruciate Ligament Reconstruction Chen, Rong‐jin Zhu, Hao‐zhong Gu, Xin‐yi Xiang, Xian‐xiang Orthop Surg Clinical Articles OBJECTIVE: To investigate the effect of platelet‐rich plasma on tendon‐bone healing after anterior cruciate ligament reconstruction. METHODS: This retrospective study included 85 patients (range, 18–50 years; mean age, 33.95 ± 10.53 years; male/female, 49/36) who underwent anterior cruciate ligament reconstruction using autologous hamstring tendons between August 2017 and June 2019 at our institute. The participants in the study group (n = 42) were injected with platelet‐rich plasma at both ends of the tendon graft, while those in the control group (n = 43) received an injection of normal saline. Magnetic resonance imaging signal/noise quotient values of the femoral and tibial ends, knee Lysholm scores, and International Knee Documentation Committee scores were compared at 3, 6, and 12 months postoperatively. RESULTS: The signal/noise quotient values of the femoral and tibial ends in both groups were higher at 6 months than at 3 and 12 months postoperatively. The signal/noise quotient values of the tibial end were significantly lower in the platelet‐rich plasma group than in the normal saline group at all follow‐up time points (P < 0.05). The signal/noise quotient values of the tibial and femoral ends in both groups were significantly different at 3, 6, and 12 months postoperatively (P < 0.05). Additionally, the signal/noise quotient values of the tibia were significantly lower than those of the femur in both groups (P < 0.05). The Lysholm and International Knee Documentation Committee scores were significantly better in the platelet‐rich plasma group than in the normal saline group only at 3 months postoperatively. No complications, such as knee joint infection or vascular and nerve injuries, occurred in any of the 85 patients. The knee flexion of all patients were more than 90°, and the straight degree was 0°. No joint stiffness was observed in all patients. CONCLUSION: Platelet‐rich plasma can promote tendon‐bone healing in grafts and can improve early postoperative knee joint function. John Wiley & Sons Australia, Ltd 2021-12-06 /pmc/articles/PMC8755887/ /pubmed/34870370 http://dx.doi.org/10.1111/os.13175 Text en © 2021 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Clinical Articles
Chen, Rong‐jin
Zhu, Hao‐zhong
Gu, Xin‐yi
Xiang, Xian‐xiang
Effects of Platelet‐Rich Plasma on Tendon‐Bone Healing After Anterior Cruciate Ligament Reconstruction
title Effects of Platelet‐Rich Plasma on Tendon‐Bone Healing After Anterior Cruciate Ligament Reconstruction
title_full Effects of Platelet‐Rich Plasma on Tendon‐Bone Healing After Anterior Cruciate Ligament Reconstruction
title_fullStr Effects of Platelet‐Rich Plasma on Tendon‐Bone Healing After Anterior Cruciate Ligament Reconstruction
title_full_unstemmed Effects of Platelet‐Rich Plasma on Tendon‐Bone Healing After Anterior Cruciate Ligament Reconstruction
title_short Effects of Platelet‐Rich Plasma on Tendon‐Bone Healing After Anterior Cruciate Ligament Reconstruction
title_sort effects of platelet‐rich plasma on tendon‐bone healing after anterior cruciate ligament reconstruction
topic Clinical Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8755887/
https://www.ncbi.nlm.nih.gov/pubmed/34870370
http://dx.doi.org/10.1111/os.13175
work_keys_str_mv AT chenrongjin effectsofplateletrichplasmaontendonbonehealingafteranteriorcruciateligamentreconstruction
AT zhuhaozhong effectsofplateletrichplasmaontendonbonehealingafteranteriorcruciateligamentreconstruction
AT guxinyi effectsofplateletrichplasmaontendonbonehealingafteranteriorcruciateligamentreconstruction
AT xiangxianxiang effectsofplateletrichplasmaontendonbonehealingafteranteriorcruciateligamentreconstruction