Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population
OBJECTIVE: This research aimed to developing customized pedicle screw based on Indonesian vertebral anatomy and compare the insertion time, pull-out strength, and screw-media interface area of different screw design. We have developed 3 different types of pedicle screws (v-thread cylinder-core, squa...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8756690/ https://www.ncbi.nlm.nih.gov/pubmed/35022083 http://dx.doi.org/10.1186/s13104-021-05803-5 |
_version_ | 1784632611882139648 |
---|---|
author | Magetsari, Rahadyan Rukmoyo, Tedjo Saputra, Marda Ade Sakti, Yudha Mathan |
author_facet | Magetsari, Rahadyan Rukmoyo, Tedjo Saputra, Marda Ade Sakti, Yudha Mathan |
author_sort | Magetsari, Rahadyan |
collection | PubMed |
description | OBJECTIVE: This research aimed to developing customized pedicle screw based on Indonesian vertebral anatomy and compare the insertion time, pull-out strength, and screw-media interface area of different screw design. We have developed 3 different types of pedicle screws (v-thread cylinder-core, square-thread cylinder-core and square-thread conical-core). The thread diameter was calculated from pedicle width of Indonesian population (6 mm). We used commercially available pedicle screw as control group (6.2 mm). RESULT: The insertion time were significantly difference between v-thread cylinder-core pedicle screw (22.94 s) with commercially available pedicle screw (15.86 s) (p < 0.05). The pull-out strength was significantly difference between commercially available pedicle screw (408.60 N) with square-thread conical pedicle screw (836.60 N) (p < 0.05). The square-thread conical-core group have the highest interface area (1486.21 mm(2)). The data comparison showed that the square-thread conical-core customized pedicle screw group has comparable insertion time and has better pull-out strength than commercially available pedicle screw. |
format | Online Article Text |
id | pubmed-8756690 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-87566902022-01-18 Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population Magetsari, Rahadyan Rukmoyo, Tedjo Saputra, Marda Ade Sakti, Yudha Mathan BMC Res Notes Research Note OBJECTIVE: This research aimed to developing customized pedicle screw based on Indonesian vertebral anatomy and compare the insertion time, pull-out strength, and screw-media interface area of different screw design. We have developed 3 different types of pedicle screws (v-thread cylinder-core, square-thread cylinder-core and square-thread conical-core). The thread diameter was calculated from pedicle width of Indonesian population (6 mm). We used commercially available pedicle screw as control group (6.2 mm). RESULT: The insertion time were significantly difference between v-thread cylinder-core pedicle screw (22.94 s) with commercially available pedicle screw (15.86 s) (p < 0.05). The pull-out strength was significantly difference between commercially available pedicle screw (408.60 N) with square-thread conical pedicle screw (836.60 N) (p < 0.05). The square-thread conical-core group have the highest interface area (1486.21 mm(2)). The data comparison showed that the square-thread conical-core customized pedicle screw group has comparable insertion time and has better pull-out strength than commercially available pedicle screw. BioMed Central 2022-01-12 /pmc/articles/PMC8756690/ /pubmed/35022083 http://dx.doi.org/10.1186/s13104-021-05803-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Note Magetsari, Rahadyan Rukmoyo, Tedjo Saputra, Marda Ade Sakti, Yudha Mathan Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population |
title | Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population |
title_full | Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population |
title_fullStr | Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population |
title_full_unstemmed | Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population |
title_short | Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population |
title_sort | comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on indonesian population |
topic | Research Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8756690/ https://www.ncbi.nlm.nih.gov/pubmed/35022083 http://dx.doi.org/10.1186/s13104-021-05803-5 |
work_keys_str_mv | AT magetsarirahadyan comparisonofinsertiontimepulloutstrengthandscrewmediainterfaceareaofcustomizedpediclescrewwithdifferentcoreandthreaddesignagainstcommercialpediclescrewapilotstudyonindonesianpopulation AT rukmoyotedjo comparisonofinsertiontimepulloutstrengthandscrewmediainterfaceareaofcustomizedpediclescrewwithdifferentcoreandthreaddesignagainstcommercialpediclescrewapilotstudyonindonesianpopulation AT saputramardaade comparisonofinsertiontimepulloutstrengthandscrewmediainterfaceareaofcustomizedpediclescrewwithdifferentcoreandthreaddesignagainstcommercialpediclescrewapilotstudyonindonesianpopulation AT saktiyudhamathan comparisonofinsertiontimepulloutstrengthandscrewmediainterfaceareaofcustomizedpediclescrewwithdifferentcoreandthreaddesignagainstcommercialpediclescrewapilotstudyonindonesianpopulation |