Cargando…

Development and validation of quantitative thin layer chromatographic technique for determination of total aflatoxins in poultry feed and food grains without sample clean-up

OBJECTIVE: The purpose of this work is to develop and validate an appropriate solvent solution and quantitative thin layer chromatography (TLC) method for determining the aflatoxins content of chicken feeds and dietary grains. MATERIALS AND METHODS: To obtain the optimal mobile phase, samples were e...

Descripción completa

Detalles Bibliográficos
Autores principales: Salisu, Bahauddeen, Anua, Siti Marwanis, Ishak, Wan Rosli Wan, Mazlan, Nurzafirah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: A periodical of the Network for the Veterinarians of Bangladesh (BDvetNET) 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8757678/
https://www.ncbi.nlm.nih.gov/pubmed/35106307
http://dx.doi.org/10.5455/javar.2021.h558
_version_ 1784632728709234688
author Salisu, Bahauddeen
Anua, Siti Marwanis
Ishak, Wan Rosli Wan
Mazlan, Nurzafirah
author_facet Salisu, Bahauddeen
Anua, Siti Marwanis
Ishak, Wan Rosli Wan
Mazlan, Nurzafirah
author_sort Salisu, Bahauddeen
collection PubMed
description OBJECTIVE: The purpose of this work is to develop and validate an appropriate solvent solution and quantitative thin layer chromatography (TLC) method for determining the aflatoxins content of chicken feeds and dietary grains. MATERIALS AND METHODS: To obtain the optimal mobile phase, samples were extracted with methanol/water (3:1) + 5% sodium chloride and partitioned using several solvent systems using preparative TLC. Camag TLC scanner 3 was used to scan the TLC plates at 366 nm and quantify them using JustTLC software. The method was tested for linearity, specificity, accuracy, precision, sensitivity, and robustness in accordance with ICH recommendations, and then utilized to screen 132 Nigerian poultry/food samples for total aflatoxins (TAFs). RESULTS: The best separation of aflatoxins was achieved using acetonitrile and dichloromethane (3:17) mobile phase over an average run time of 45 min, resulting in linear calibration curves (R(2) > 0.99) in the concentration range limit of quantitation (LoQ) to 50 ng/spot with a limit of detection of <2.0 ng/g and a LoQ of <4.0 ng/gm for all aflatoxins in all spiked samples. When the proposed TLC method was compared to an optimized high-performance liquid chromatography method, an excellent linear regression was obtained (R(2) > 95%). Seventy seven (58.33%) of the 132 samples examined were positive for aflatoxins, with mean values ranging from 3.57 ± 2.55 to 37.31 ± 34.06 ng/gm for aflatoxin B1 and 6.67 ± 0.00 to 38.02 ± 31.52 ng/gm for TAFs, respectively. CONCLUSIONS: The results demonstrate the feasibility of using the suggested TLC method in conjunction with a novel solvent solution (free of carcinogenic chloroform) for the rapid and accurate measurement of TAFs in foods/feeds.
format Online
Article
Text
id pubmed-8757678
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher A periodical of the Network for the Veterinarians of Bangladesh (BDvetNET)
record_format MEDLINE/PubMed
spelling pubmed-87576782022-01-31 Development and validation of quantitative thin layer chromatographic technique for determination of total aflatoxins in poultry feed and food grains without sample clean-up Salisu, Bahauddeen Anua, Siti Marwanis Ishak, Wan Rosli Wan Mazlan, Nurzafirah J Adv Vet Anim Res Original Article OBJECTIVE: The purpose of this work is to develop and validate an appropriate solvent solution and quantitative thin layer chromatography (TLC) method for determining the aflatoxins content of chicken feeds and dietary grains. MATERIALS AND METHODS: To obtain the optimal mobile phase, samples were extracted with methanol/water (3:1) + 5% sodium chloride and partitioned using several solvent systems using preparative TLC. Camag TLC scanner 3 was used to scan the TLC plates at 366 nm and quantify them using JustTLC software. The method was tested for linearity, specificity, accuracy, precision, sensitivity, and robustness in accordance with ICH recommendations, and then utilized to screen 132 Nigerian poultry/food samples for total aflatoxins (TAFs). RESULTS: The best separation of aflatoxins was achieved using acetonitrile and dichloromethane (3:17) mobile phase over an average run time of 45 min, resulting in linear calibration curves (R(2) > 0.99) in the concentration range limit of quantitation (LoQ) to 50 ng/spot with a limit of detection of <2.0 ng/g and a LoQ of <4.0 ng/gm for all aflatoxins in all spiked samples. When the proposed TLC method was compared to an optimized high-performance liquid chromatography method, an excellent linear regression was obtained (R(2) > 95%). Seventy seven (58.33%) of the 132 samples examined were positive for aflatoxins, with mean values ranging from 3.57 ± 2.55 to 37.31 ± 34.06 ng/gm for aflatoxin B1 and 6.67 ± 0.00 to 38.02 ± 31.52 ng/gm for TAFs, respectively. CONCLUSIONS: The results demonstrate the feasibility of using the suggested TLC method in conjunction with a novel solvent solution (free of carcinogenic chloroform) for the rapid and accurate measurement of TAFs in foods/feeds. A periodical of the Network for the Veterinarians of Bangladesh (BDvetNET) 2021-11-06 /pmc/articles/PMC8757678/ /pubmed/35106307 http://dx.doi.org/10.5455/javar.2021.h558 Text en Copyright: © Journal of Advanced Veterinary and Animal Research https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License (http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/) )
spellingShingle Original Article
Salisu, Bahauddeen
Anua, Siti Marwanis
Ishak, Wan Rosli Wan
Mazlan, Nurzafirah
Development and validation of quantitative thin layer chromatographic technique for determination of total aflatoxins in poultry feed and food grains without sample clean-up
title Development and validation of quantitative thin layer chromatographic technique for determination of total aflatoxins in poultry feed and food grains without sample clean-up
title_full Development and validation of quantitative thin layer chromatographic technique for determination of total aflatoxins in poultry feed and food grains without sample clean-up
title_fullStr Development and validation of quantitative thin layer chromatographic technique for determination of total aflatoxins in poultry feed and food grains without sample clean-up
title_full_unstemmed Development and validation of quantitative thin layer chromatographic technique for determination of total aflatoxins in poultry feed and food grains without sample clean-up
title_short Development and validation of quantitative thin layer chromatographic technique for determination of total aflatoxins in poultry feed and food grains without sample clean-up
title_sort development and validation of quantitative thin layer chromatographic technique for determination of total aflatoxins in poultry feed and food grains without sample clean-up
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8757678/
https://www.ncbi.nlm.nih.gov/pubmed/35106307
http://dx.doi.org/10.5455/javar.2021.h558
work_keys_str_mv AT salisubahauddeen developmentandvalidationofquantitativethinlayerchromatographictechniquefordeterminationoftotalaflatoxinsinpoultryfeedandfoodgrainswithoutsamplecleanup
AT anuasitimarwanis developmentandvalidationofquantitativethinlayerchromatographictechniquefordeterminationoftotalaflatoxinsinpoultryfeedandfoodgrainswithoutsamplecleanup
AT ishakwanrosliwan developmentandvalidationofquantitativethinlayerchromatographictechniquefordeterminationoftotalaflatoxinsinpoultryfeedandfoodgrainswithoutsamplecleanup
AT mazlannurzafirah developmentandvalidationofquantitativethinlayerchromatographictechniquefordeterminationoftotalaflatoxinsinpoultryfeedandfoodgrainswithoutsamplecleanup