Cargando…
A Novel Ventilator Design for COVID-19 and Resource-Limited Settings
There has existed a severe ventilator deficit in much of the world for many years, due in part to the high cost and complexity of traditional ICU ventilators. This was highlighted and exacerbated by the emergence of the COVID-19 pandemic, during which the increase in ventilator production rapidly ov...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8757831/ https://www.ncbi.nlm.nih.gov/pubmed/35047946 http://dx.doi.org/10.3389/fmedt.2021.707826 |
_version_ | 1784632766365696000 |
---|---|
author | Madekurozwa, Michael Bonneuil, Willy V. Frattolin, Jennifer Watson, Daniel J. Moore, Axel C. Stevens, Molly M. Moore, James Mathiszig-Lee, Jakob van Batenburg-Sherwood, Joseph |
author_facet | Madekurozwa, Michael Bonneuil, Willy V. Frattolin, Jennifer Watson, Daniel J. Moore, Axel C. Stevens, Molly M. Moore, James Mathiszig-Lee, Jakob van Batenburg-Sherwood, Joseph |
author_sort | Madekurozwa, Michael |
collection | PubMed |
description | There has existed a severe ventilator deficit in much of the world for many years, due in part to the high cost and complexity of traditional ICU ventilators. This was highlighted and exacerbated by the emergence of the COVID-19 pandemic, during which the increase in ventilator production rapidly overran the global supply chains for components. In response, we propose a new approach to ventilator design that meets the performance requirements for COVID-19 patients, while using components that minimise interference with the existing ventilator supply chains. The majority of current ventilator designs use proportional valves and flow sensors, which remain in short supply over a year into the pandemic. In the proposed design, the core components are on-off valves. Unlike proportional valves, on-off valves are widely available, but accurate control of ventilation using on-off valves is not straightforward. Our proposed solution combines four on-off valves, a two-litre reservoir, an oxygen sensor and two pressure sensors. Benchtop testing of a prototype was performed with a commercially available flow analyser and test lungs. We investigated the accuracy and precision of the prototype using both compressed gas supplies and a portable oxygen concentrator, and demonstrated the long-term durability over 15 days. The precision and accuracy of ventilation parameters were within the ranges specified in international guidelines in all tests. A numerical model of the system was developed and validated against experimental data. The model was used to determine usable ranges of valve flow coefficients to increase supply chain flexibility. This new design provides the performance necessary for the majority of patients that require ventilation. Applications include COVID-19 as well as pneumonia, influenza, and tuberculosis, which remain major causes of mortality in low and middle income countries. The robustness, energy efficiency, ease of maintenance, price and availability of on-off valves are all advantageous over proportional valves. As a result, the proposed ventilator design will cost significantly less to manufacture and maintain than current market designs and has the potential to increase global ventilator availability. |
format | Online Article Text |
id | pubmed-8757831 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-87578312022-01-18 A Novel Ventilator Design for COVID-19 and Resource-Limited Settings Madekurozwa, Michael Bonneuil, Willy V. Frattolin, Jennifer Watson, Daniel J. Moore, Axel C. Stevens, Molly M. Moore, James Mathiszig-Lee, Jakob van Batenburg-Sherwood, Joseph Front Med Technol Medical Technology There has existed a severe ventilator deficit in much of the world for many years, due in part to the high cost and complexity of traditional ICU ventilators. This was highlighted and exacerbated by the emergence of the COVID-19 pandemic, during which the increase in ventilator production rapidly overran the global supply chains for components. In response, we propose a new approach to ventilator design that meets the performance requirements for COVID-19 patients, while using components that minimise interference with the existing ventilator supply chains. The majority of current ventilator designs use proportional valves and flow sensors, which remain in short supply over a year into the pandemic. In the proposed design, the core components are on-off valves. Unlike proportional valves, on-off valves are widely available, but accurate control of ventilation using on-off valves is not straightforward. Our proposed solution combines four on-off valves, a two-litre reservoir, an oxygen sensor and two pressure sensors. Benchtop testing of a prototype was performed with a commercially available flow analyser and test lungs. We investigated the accuracy and precision of the prototype using both compressed gas supplies and a portable oxygen concentrator, and demonstrated the long-term durability over 15 days. The precision and accuracy of ventilation parameters were within the ranges specified in international guidelines in all tests. A numerical model of the system was developed and validated against experimental data. The model was used to determine usable ranges of valve flow coefficients to increase supply chain flexibility. This new design provides the performance necessary for the majority of patients that require ventilation. Applications include COVID-19 as well as pneumonia, influenza, and tuberculosis, which remain major causes of mortality in low and middle income countries. The robustness, energy efficiency, ease of maintenance, price and availability of on-off valves are all advantageous over proportional valves. As a result, the proposed ventilator design will cost significantly less to manufacture and maintain than current market designs and has the potential to increase global ventilator availability. Frontiers Media S.A. 2021-10-04 /pmc/articles/PMC8757831/ /pubmed/35047946 http://dx.doi.org/10.3389/fmedt.2021.707826 Text en Copyright © 2021 Madekurozwa, Bonneuil, Frattolin, Watson, Moore, Stevens, Moore, Mathiszig-Lee and van Batenburg-Sherwood. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medical Technology Madekurozwa, Michael Bonneuil, Willy V. Frattolin, Jennifer Watson, Daniel J. Moore, Axel C. Stevens, Molly M. Moore, James Mathiszig-Lee, Jakob van Batenburg-Sherwood, Joseph A Novel Ventilator Design for COVID-19 and Resource-Limited Settings |
title | A Novel Ventilator Design for COVID-19 and Resource-Limited Settings |
title_full | A Novel Ventilator Design for COVID-19 and Resource-Limited Settings |
title_fullStr | A Novel Ventilator Design for COVID-19 and Resource-Limited Settings |
title_full_unstemmed | A Novel Ventilator Design for COVID-19 and Resource-Limited Settings |
title_short | A Novel Ventilator Design for COVID-19 and Resource-Limited Settings |
title_sort | novel ventilator design for covid-19 and resource-limited settings |
topic | Medical Technology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8757831/ https://www.ncbi.nlm.nih.gov/pubmed/35047946 http://dx.doi.org/10.3389/fmedt.2021.707826 |
work_keys_str_mv | AT madekurozwamichael anovelventilatordesignforcovid19andresourcelimitedsettings AT bonneuilwillyv anovelventilatordesignforcovid19andresourcelimitedsettings AT frattolinjennifer anovelventilatordesignforcovid19andresourcelimitedsettings AT watsondanielj anovelventilatordesignforcovid19andresourcelimitedsettings AT mooreaxelc anovelventilatordesignforcovid19andresourcelimitedsettings AT stevensmollym anovelventilatordesignforcovid19andresourcelimitedsettings AT moorejames anovelventilatordesignforcovid19andresourcelimitedsettings AT mathiszigleejakob anovelventilatordesignforcovid19andresourcelimitedsettings AT vanbatenburgsherwoodjoseph anovelventilatordesignforcovid19andresourcelimitedsettings AT madekurozwamichael novelventilatordesignforcovid19andresourcelimitedsettings AT bonneuilwillyv novelventilatordesignforcovid19andresourcelimitedsettings AT frattolinjennifer novelventilatordesignforcovid19andresourcelimitedsettings AT watsondanielj novelventilatordesignforcovid19andresourcelimitedsettings AT mooreaxelc novelventilatordesignforcovid19andresourcelimitedsettings AT stevensmollym novelventilatordesignforcovid19andresourcelimitedsettings AT moorejames novelventilatordesignforcovid19andresourcelimitedsettings AT mathiszigleejakob novelventilatordesignforcovid19andresourcelimitedsettings AT vanbatenburgsherwoodjoseph novelventilatordesignforcovid19andresourcelimitedsettings |