Cargando…

A Novel Ventilator Design for COVID-19 and Resource-Limited Settings

There has existed a severe ventilator deficit in much of the world for many years, due in part to the high cost and complexity of traditional ICU ventilators. This was highlighted and exacerbated by the emergence of the COVID-19 pandemic, during which the increase in ventilator production rapidly ov...

Descripción completa

Detalles Bibliográficos
Autores principales: Madekurozwa, Michael, Bonneuil, Willy V., Frattolin, Jennifer, Watson, Daniel J., Moore, Axel C., Stevens, Molly M., Moore, James, Mathiszig-Lee, Jakob, van Batenburg-Sherwood, Joseph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8757831/
https://www.ncbi.nlm.nih.gov/pubmed/35047946
http://dx.doi.org/10.3389/fmedt.2021.707826
_version_ 1784632766365696000
author Madekurozwa, Michael
Bonneuil, Willy V.
Frattolin, Jennifer
Watson, Daniel J.
Moore, Axel C.
Stevens, Molly M.
Moore, James
Mathiszig-Lee, Jakob
van Batenburg-Sherwood, Joseph
author_facet Madekurozwa, Michael
Bonneuil, Willy V.
Frattolin, Jennifer
Watson, Daniel J.
Moore, Axel C.
Stevens, Molly M.
Moore, James
Mathiszig-Lee, Jakob
van Batenburg-Sherwood, Joseph
author_sort Madekurozwa, Michael
collection PubMed
description There has existed a severe ventilator deficit in much of the world for many years, due in part to the high cost and complexity of traditional ICU ventilators. This was highlighted and exacerbated by the emergence of the COVID-19 pandemic, during which the increase in ventilator production rapidly overran the global supply chains for components. In response, we propose a new approach to ventilator design that meets the performance requirements for COVID-19 patients, while using components that minimise interference with the existing ventilator supply chains. The majority of current ventilator designs use proportional valves and flow sensors, which remain in short supply over a year into the pandemic. In the proposed design, the core components are on-off valves. Unlike proportional valves, on-off valves are widely available, but accurate control of ventilation using on-off valves is not straightforward. Our proposed solution combines four on-off valves, a two-litre reservoir, an oxygen sensor and two pressure sensors. Benchtop testing of a prototype was performed with a commercially available flow analyser and test lungs. We investigated the accuracy and precision of the prototype using both compressed gas supplies and a portable oxygen concentrator, and demonstrated the long-term durability over 15 days. The precision and accuracy of ventilation parameters were within the ranges specified in international guidelines in all tests. A numerical model of the system was developed and validated against experimental data. The model was used to determine usable ranges of valve flow coefficients to increase supply chain flexibility. This new design provides the performance necessary for the majority of patients that require ventilation. Applications include COVID-19 as well as pneumonia, influenza, and tuberculosis, which remain major causes of mortality in low and middle income countries. The robustness, energy efficiency, ease of maintenance, price and availability of on-off valves are all advantageous over proportional valves. As a result, the proposed ventilator design will cost significantly less to manufacture and maintain than current market designs and has the potential to increase global ventilator availability.
format Online
Article
Text
id pubmed-8757831
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87578312022-01-18 A Novel Ventilator Design for COVID-19 and Resource-Limited Settings Madekurozwa, Michael Bonneuil, Willy V. Frattolin, Jennifer Watson, Daniel J. Moore, Axel C. Stevens, Molly M. Moore, James Mathiszig-Lee, Jakob van Batenburg-Sherwood, Joseph Front Med Technol Medical Technology There has existed a severe ventilator deficit in much of the world for many years, due in part to the high cost and complexity of traditional ICU ventilators. This was highlighted and exacerbated by the emergence of the COVID-19 pandemic, during which the increase in ventilator production rapidly overran the global supply chains for components. In response, we propose a new approach to ventilator design that meets the performance requirements for COVID-19 patients, while using components that minimise interference with the existing ventilator supply chains. The majority of current ventilator designs use proportional valves and flow sensors, which remain in short supply over a year into the pandemic. In the proposed design, the core components are on-off valves. Unlike proportional valves, on-off valves are widely available, but accurate control of ventilation using on-off valves is not straightforward. Our proposed solution combines four on-off valves, a two-litre reservoir, an oxygen sensor and two pressure sensors. Benchtop testing of a prototype was performed with a commercially available flow analyser and test lungs. We investigated the accuracy and precision of the prototype using both compressed gas supplies and a portable oxygen concentrator, and demonstrated the long-term durability over 15 days. The precision and accuracy of ventilation parameters were within the ranges specified in international guidelines in all tests. A numerical model of the system was developed and validated against experimental data. The model was used to determine usable ranges of valve flow coefficients to increase supply chain flexibility. This new design provides the performance necessary for the majority of patients that require ventilation. Applications include COVID-19 as well as pneumonia, influenza, and tuberculosis, which remain major causes of mortality in low and middle income countries. The robustness, energy efficiency, ease of maintenance, price and availability of on-off valves are all advantageous over proportional valves. As a result, the proposed ventilator design will cost significantly less to manufacture and maintain than current market designs and has the potential to increase global ventilator availability. Frontiers Media S.A. 2021-10-04 /pmc/articles/PMC8757831/ /pubmed/35047946 http://dx.doi.org/10.3389/fmedt.2021.707826 Text en Copyright © 2021 Madekurozwa, Bonneuil, Frattolin, Watson, Moore, Stevens, Moore, Mathiszig-Lee and van Batenburg-Sherwood. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medical Technology
Madekurozwa, Michael
Bonneuil, Willy V.
Frattolin, Jennifer
Watson, Daniel J.
Moore, Axel C.
Stevens, Molly M.
Moore, James
Mathiszig-Lee, Jakob
van Batenburg-Sherwood, Joseph
A Novel Ventilator Design for COVID-19 and Resource-Limited Settings
title A Novel Ventilator Design for COVID-19 and Resource-Limited Settings
title_full A Novel Ventilator Design for COVID-19 and Resource-Limited Settings
title_fullStr A Novel Ventilator Design for COVID-19 and Resource-Limited Settings
title_full_unstemmed A Novel Ventilator Design for COVID-19 and Resource-Limited Settings
title_short A Novel Ventilator Design for COVID-19 and Resource-Limited Settings
title_sort novel ventilator design for covid-19 and resource-limited settings
topic Medical Technology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8757831/
https://www.ncbi.nlm.nih.gov/pubmed/35047946
http://dx.doi.org/10.3389/fmedt.2021.707826
work_keys_str_mv AT madekurozwamichael anovelventilatordesignforcovid19andresourcelimitedsettings
AT bonneuilwillyv anovelventilatordesignforcovid19andresourcelimitedsettings
AT frattolinjennifer anovelventilatordesignforcovid19andresourcelimitedsettings
AT watsondanielj anovelventilatordesignforcovid19andresourcelimitedsettings
AT mooreaxelc anovelventilatordesignforcovid19andresourcelimitedsettings
AT stevensmollym anovelventilatordesignforcovid19andresourcelimitedsettings
AT moorejames anovelventilatordesignforcovid19andresourcelimitedsettings
AT mathiszigleejakob anovelventilatordesignforcovid19andresourcelimitedsettings
AT vanbatenburgsherwoodjoseph anovelventilatordesignforcovid19andresourcelimitedsettings
AT madekurozwamichael novelventilatordesignforcovid19andresourcelimitedsettings
AT bonneuilwillyv novelventilatordesignforcovid19andresourcelimitedsettings
AT frattolinjennifer novelventilatordesignforcovid19andresourcelimitedsettings
AT watsondanielj novelventilatordesignforcovid19andresourcelimitedsettings
AT mooreaxelc novelventilatordesignforcovid19andresourcelimitedsettings
AT stevensmollym novelventilatordesignforcovid19andresourcelimitedsettings
AT moorejames novelventilatordesignforcovid19andresourcelimitedsettings
AT mathiszigleejakob novelventilatordesignforcovid19andresourcelimitedsettings
AT vanbatenburgsherwoodjoseph novelventilatordesignforcovid19andresourcelimitedsettings