Cargando…

Detection of Clenbuterol-Induced Changes in Heart Rate Using At-Home Recorded Smartwatch Data: Randomized Controlled Trial

BACKGROUND: Although electrocardiography is the gold standard for heart rate (HR) recording in clinical trials, the increasing availability of smartwatch-based HR monitors opens up possibilities for drug development studies. Smartwatches allow for inexpensive, unobtrusive, and continuous HR estimati...

Descripción completa

Detalles Bibliográficos
Autores principales: Elzinga, Willem O, Prins, Samantha, Borghans, Laura G J M, Gal, Pim, Vargas, Gabriel A, Groeneveld, Geert J, Doll, Robert J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8759015/
https://www.ncbi.nlm.nih.gov/pubmed/34967757
http://dx.doi.org/10.2196/31890
_version_ 1784633025605140480
author Elzinga, Willem O
Prins, Samantha
Borghans, Laura G J M
Gal, Pim
Vargas, Gabriel A
Groeneveld, Geert J
Doll, Robert J
author_facet Elzinga, Willem O
Prins, Samantha
Borghans, Laura G J M
Gal, Pim
Vargas, Gabriel A
Groeneveld, Geert J
Doll, Robert J
author_sort Elzinga, Willem O
collection PubMed
description BACKGROUND: Although electrocardiography is the gold standard for heart rate (HR) recording in clinical trials, the increasing availability of smartwatch-based HR monitors opens up possibilities for drug development studies. Smartwatches allow for inexpensive, unobtrusive, and continuous HR estimation for potential detection of treatment effects outside the clinic, during daily life. OBJECTIVE: The aim of this study is to evaluate the repeatability and sensitivity of smartwatch-based HR estimates collected during a randomized clinical trial. METHODS: The data were collected as part of a multiple-dose, investigator-blinded, randomized, placebo-controlled, parallel-group study of 12 patients with Parkinson disease. After a 6-day baseline period, 4 and 8 patients were treated for 7 days with an ascending dose of placebo and clenbuterol, respectively. Throughout the study, the smartwatch provided HR and sleep state estimates. The HR estimates were quantified as the 2.5th, 50th, and 97.5th percentiles within awake and asleep segments. Linear mixed models were used to calculate the following: (1) the intraclass correlation coefficient (ICC) of estimated sleep durations, (2) the ICC and minimum detectable effect (MDE) of the HR estimates, and (3) the effect sizes of the HR estimates. RESULTS: Sleep duration was moderately repeatable (ICC=0.64) and was not significantly affected by study day (P=.83), clenbuterol (P=.43), and study day by clenbuterol (P=.73). Clenbuterol-induced changes were detected in the asleep HR as of the first night (+3.79 beats per minute [bpm], P=.04) and in the awake HR as of the third day (+8.79 bpm, P=.001). The median HR while asleep had the highest repeatability (ICC=0.70). The MDE (N=12) was found to be smaller when patients were asleep (6.8 bpm to 11.7 bpm) than while awake (10.7 bpm to 22.1 bpm). Overall, the effect sizes for clenbuterol-induced changes were higher while asleep (0.49 to 2.75) than while awake (0.08 to 1.94). CONCLUSIONS: We demonstrated the feasibility of using smartwatch-based HR estimates to detect clenbuterol-induced changes during clinical trials. The asleep HR estimates were most repeatable and sensitive to treatment effects. We conclude that smartwatch-based HR estimates obtained during daily living in a clinical trial can be used to detect and track treatment effects. TRIAL REGISTRATION: Netherlands Trials Register NL8002; https://www.trialregister.nl/trial/8002
format Online
Article
Text
id pubmed-8759015
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-87590152022-02-03 Detection of Clenbuterol-Induced Changes in Heart Rate Using At-Home Recorded Smartwatch Data: Randomized Controlled Trial Elzinga, Willem O Prins, Samantha Borghans, Laura G J M Gal, Pim Vargas, Gabriel A Groeneveld, Geert J Doll, Robert J JMIR Form Res Original Paper BACKGROUND: Although electrocardiography is the gold standard for heart rate (HR) recording in clinical trials, the increasing availability of smartwatch-based HR monitors opens up possibilities for drug development studies. Smartwatches allow for inexpensive, unobtrusive, and continuous HR estimation for potential detection of treatment effects outside the clinic, during daily life. OBJECTIVE: The aim of this study is to evaluate the repeatability and sensitivity of smartwatch-based HR estimates collected during a randomized clinical trial. METHODS: The data were collected as part of a multiple-dose, investigator-blinded, randomized, placebo-controlled, parallel-group study of 12 patients with Parkinson disease. After a 6-day baseline period, 4 and 8 patients were treated for 7 days with an ascending dose of placebo and clenbuterol, respectively. Throughout the study, the smartwatch provided HR and sleep state estimates. The HR estimates were quantified as the 2.5th, 50th, and 97.5th percentiles within awake and asleep segments. Linear mixed models were used to calculate the following: (1) the intraclass correlation coefficient (ICC) of estimated sleep durations, (2) the ICC and minimum detectable effect (MDE) of the HR estimates, and (3) the effect sizes of the HR estimates. RESULTS: Sleep duration was moderately repeatable (ICC=0.64) and was not significantly affected by study day (P=.83), clenbuterol (P=.43), and study day by clenbuterol (P=.73). Clenbuterol-induced changes were detected in the asleep HR as of the first night (+3.79 beats per minute [bpm], P=.04) and in the awake HR as of the third day (+8.79 bpm, P=.001). The median HR while asleep had the highest repeatability (ICC=0.70). The MDE (N=12) was found to be smaller when patients were asleep (6.8 bpm to 11.7 bpm) than while awake (10.7 bpm to 22.1 bpm). Overall, the effect sizes for clenbuterol-induced changes were higher while asleep (0.49 to 2.75) than while awake (0.08 to 1.94). CONCLUSIONS: We demonstrated the feasibility of using smartwatch-based HR estimates to detect clenbuterol-induced changes during clinical trials. The asleep HR estimates were most repeatable and sensitive to treatment effects. We conclude that smartwatch-based HR estimates obtained during daily living in a clinical trial can be used to detect and track treatment effects. TRIAL REGISTRATION: Netherlands Trials Register NL8002; https://www.trialregister.nl/trial/8002 JMIR Publications 2021-12-30 /pmc/articles/PMC8759015/ /pubmed/34967757 http://dx.doi.org/10.2196/31890 Text en ©Willem O Elzinga, Samantha Prins, Laura G J M Borghans, Pim Gal, Gabriel A Vargas, Geert J Groeneveld, Robert J Doll. Originally published in JMIR Formative Research (https://formative.jmir.org), 30.12.2021. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on https://formative.jmir.org, as well as this copyright and license information must be included.
spellingShingle Original Paper
Elzinga, Willem O
Prins, Samantha
Borghans, Laura G J M
Gal, Pim
Vargas, Gabriel A
Groeneveld, Geert J
Doll, Robert J
Detection of Clenbuterol-Induced Changes in Heart Rate Using At-Home Recorded Smartwatch Data: Randomized Controlled Trial
title Detection of Clenbuterol-Induced Changes in Heart Rate Using At-Home Recorded Smartwatch Data: Randomized Controlled Trial
title_full Detection of Clenbuterol-Induced Changes in Heart Rate Using At-Home Recorded Smartwatch Data: Randomized Controlled Trial
title_fullStr Detection of Clenbuterol-Induced Changes in Heart Rate Using At-Home Recorded Smartwatch Data: Randomized Controlled Trial
title_full_unstemmed Detection of Clenbuterol-Induced Changes in Heart Rate Using At-Home Recorded Smartwatch Data: Randomized Controlled Trial
title_short Detection of Clenbuterol-Induced Changes in Heart Rate Using At-Home Recorded Smartwatch Data: Randomized Controlled Trial
title_sort detection of clenbuterol-induced changes in heart rate using at-home recorded smartwatch data: randomized controlled trial
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8759015/
https://www.ncbi.nlm.nih.gov/pubmed/34967757
http://dx.doi.org/10.2196/31890
work_keys_str_mv AT elzingawillemo detectionofclenbuterolinducedchangesinheartrateusingathomerecordedsmartwatchdatarandomizedcontrolledtrial
AT prinssamantha detectionofclenbuterolinducedchangesinheartrateusingathomerecordedsmartwatchdatarandomizedcontrolledtrial
AT borghanslauragjm detectionofclenbuterolinducedchangesinheartrateusingathomerecordedsmartwatchdatarandomizedcontrolledtrial
AT galpim detectionofclenbuterolinducedchangesinheartrateusingathomerecordedsmartwatchdatarandomizedcontrolledtrial
AT vargasgabriela detectionofclenbuterolinducedchangesinheartrateusingathomerecordedsmartwatchdatarandomizedcontrolledtrial
AT groeneveldgeertj detectionofclenbuterolinducedchangesinheartrateusingathomerecordedsmartwatchdatarandomizedcontrolledtrial
AT dollrobertj detectionofclenbuterolinducedchangesinheartrateusingathomerecordedsmartwatchdatarandomizedcontrolledtrial