A 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone

Background. The present study aimed to assess the stress and strain distribution on mini-screws and the surrounding bone in cases of different cortical bone thicknesses (CBTs), mini-screw insertion angles, and force directions using finite element analysis (FEA). Methods. Inventor professional versi...

Descripción completa

Detalles Bibliográficos
Autores principales: Auwer, Omar Nazal, Shamaa, Marwa Sameh, Hammad, Shaza Mohammad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8760373/
https://www.ncbi.nlm.nih.gov/pubmed/35070180
http://dx.doi.org/10.34172/joddd.2021.043
_version_ 1784633304244289536
author Auwer, Omar Nazal
Shamaa, Marwa Sameh
Hammad, Shaza Mohammad
author_facet Auwer, Omar Nazal
Shamaa, Marwa Sameh
Hammad, Shaza Mohammad
author_sort Auwer, Omar Nazal
collection PubMed
description Background. The present study aimed to assess the stress and strain distribution on mini-screws and the surrounding bone in cases of different cortical bone thicknesses (CBTs), mini-screw insertion angles, and force directions using finite element analysis (FEA). Methods. Inventor professional version 8 software was used to construct 24 three-dimensional assemblies of mini-screws inserted with different insertion angles (30º, 60º, and 90º) in alveolar bone blocks with different CBTs (0.5, 1, 1.5, and 2 mm). The models simulated mini-screws inserted in bones with different CBTs and different insertion angles. A 2-N load was applied in two directions to mini-screw heads. The resultant stresses of the applied load were collected from the output of the ANSYS program. Results. The results indicated that force direction affected bone strains as the horizontal force generated more strains on cortical bone than the oblique one. Force applied to 60º inserted mini-screws generated much more strains on cortical bone than 90º and 30º inserted mini-screws. In a 60º inserted mini-screw, the horizontal force generated about 45% more strains on cortical bone than the oblique one. The exerted microstrain on bone decreased as CBT increased. Conclusion. It can be concluded that inserting mini-screws at 60º to the bone surface should be avoided as it generates much more strains on cortical bone than 90º and 30º, especially when a force parallel to the bone surface is applied.
format Online
Article
Text
id pubmed-8760373
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-87603732022-01-21 A 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone Auwer, Omar Nazal Shamaa, Marwa Sameh Hammad, Shaza Mohammad J Dent Res Dent Clin Dent Prospects Original Article Background. The present study aimed to assess the stress and strain distribution on mini-screws and the surrounding bone in cases of different cortical bone thicknesses (CBTs), mini-screw insertion angles, and force directions using finite element analysis (FEA). Methods. Inventor professional version 8 software was used to construct 24 three-dimensional assemblies of mini-screws inserted with different insertion angles (30º, 60º, and 90º) in alveolar bone blocks with different CBTs (0.5, 1, 1.5, and 2 mm). The models simulated mini-screws inserted in bones with different CBTs and different insertion angles. A 2-N load was applied in two directions to mini-screw heads. The resultant stresses of the applied load were collected from the output of the ANSYS program. Results. The results indicated that force direction affected bone strains as the horizontal force generated more strains on cortical bone than the oblique one. Force applied to 60º inserted mini-screws generated much more strains on cortical bone than 90º and 30º inserted mini-screws. In a 60º inserted mini-screw, the horizontal force generated about 45% more strains on cortical bone than the oblique one. The exerted microstrain on bone decreased as CBT increased. Conclusion. It can be concluded that inserting mini-screws at 60º to the bone surface should be avoided as it generates much more strains on cortical bone than 90º and 30º, especially when a force parallel to the bone surface is applied. Tabriz University of Medical Sciences 2021 2021-12-05 /pmc/articles/PMC8760373/ /pubmed/35070180 http://dx.doi.org/10.34172/joddd.2021.043 Text en © 2021 The Author(s). https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Auwer, Omar Nazal
Shamaa, Marwa Sameh
Hammad, Shaza Mohammad
A 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone
title A 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone
title_full A 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone
title_fullStr A 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone
title_full_unstemmed A 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone
title_short A 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone
title_sort 3-dimensional finite element analysis to evaluate the impact of force direction, insertion angle, and cortical bone thickness on mini-screw and its surrounding bone
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8760373/
https://www.ncbi.nlm.nih.gov/pubmed/35070180
http://dx.doi.org/10.34172/joddd.2021.043
work_keys_str_mv AT auweromarnazal a3dimensionalfiniteelementanalysistoevaluatetheimpactofforcedirectioninsertionangleandcorticalbonethicknessonminiscrewanditssurroundingbone
AT shamaamarwasameh a3dimensionalfiniteelementanalysistoevaluatetheimpactofforcedirectioninsertionangleandcorticalbonethicknessonminiscrewanditssurroundingbone
AT hammadshazamohammad a3dimensionalfiniteelementanalysistoevaluatetheimpactofforcedirectioninsertionangleandcorticalbonethicknessonminiscrewanditssurroundingbone
AT auweromarnazal 3dimensionalfiniteelementanalysistoevaluatetheimpactofforcedirectioninsertionangleandcorticalbonethicknessonminiscrewanditssurroundingbone
AT shamaamarwasameh 3dimensionalfiniteelementanalysistoevaluatetheimpactofforcedirectioninsertionangleandcorticalbonethicknessonminiscrewanditssurroundingbone
AT hammadshazamohammad 3dimensionalfiniteelementanalysistoevaluatetheimpactofforcedirectioninsertionangleandcorticalbonethicknessonminiscrewanditssurroundingbone