Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis
BACKGROUND: The ability of end-tidal carbon dioxide (ΔEtCO2) for predicting fluid responsiveness has been extensively studied with conflicting results. This meta-analysis aimed to explore the value of ΔEtCO2 for predicting fluid responsiveness during the passive leg raising (PLR) test in patients wi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8760720/ https://www.ncbi.nlm.nih.gov/pubmed/35031070 http://dx.doi.org/10.1186/s13054-022-03890-9 |
_version_ | 1784633382331744256 |
---|---|
author | Huang, Haijun Wu, Chenxia Shen, Qinkang Fang, Yixin Xu, Hua |
author_facet | Huang, Haijun Wu, Chenxia Shen, Qinkang Fang, Yixin Xu, Hua |
author_sort | Huang, Haijun |
collection | PubMed |
description | BACKGROUND: The ability of end-tidal carbon dioxide (ΔEtCO2) for predicting fluid responsiveness has been extensively studied with conflicting results. This meta-analysis aimed to explore the value of ΔEtCO2 for predicting fluid responsiveness during the passive leg raising (PLR) test in patients with mechanical ventilation. METHODS: PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched up to November 2021. The diagnostic odds ratio (DOR), sensitivity, and specificity were calculated. The summary receiver operating characteristic curve was estimated, and the area under the curve (AUROC) was calculated. Q test and I(2) statistics were used for study heterogeneity and publication bias was assessed by Deeks’ funnel plot asymmetry test. We performed meta-regression analysis for heterogeneity exploration and sensitivity analysis for the publication bias. RESULTS: Overall, six studies including 298 patients were included in this review, of whom 149 (50%) were fluid responsive. The cutoff values of ΔEtCO2 in four studies was 5%, one was 5.8% and the other one was an absolute increase 2 mmHg. Heterogeneity between studies was assessed with an overall Q = 4.098, I(2) = 51%, and P = 0.064. The pooled sensitivity and specificity for the overall population were 0.79 (95% CI 0.72–0.85) and 0.90 (95% CI 0.77–0.96), respectively. The DOR was 35 (95% CI 12–107). The pooled AUROC was 0.81 (95% CI 0.77–0.84). On meta-regression analysis, the number of patients was sources of heterogeneity. The sensitivity analysis showed that the pooled DOR ranged from 21 to 140 and the pooled AUC ranged from 0.92 to 0.96 when one study was omitted. CONCLUSIONS: Though the limited number of studies included and study heterogeneity, our meta-analysis confirmed that the ΔEtCO2 performed moderately in predicting fluid responsiveness during the PLR test in patients with mechanical ventilation. |
format | Online Article Text |
id | pubmed-8760720 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-87607202022-01-18 Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis Huang, Haijun Wu, Chenxia Shen, Qinkang Fang, Yixin Xu, Hua Crit Care Research BACKGROUND: The ability of end-tidal carbon dioxide (ΔEtCO2) for predicting fluid responsiveness has been extensively studied with conflicting results. This meta-analysis aimed to explore the value of ΔEtCO2 for predicting fluid responsiveness during the passive leg raising (PLR) test in patients with mechanical ventilation. METHODS: PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched up to November 2021. The diagnostic odds ratio (DOR), sensitivity, and specificity were calculated. The summary receiver operating characteristic curve was estimated, and the area under the curve (AUROC) was calculated. Q test and I(2) statistics were used for study heterogeneity and publication bias was assessed by Deeks’ funnel plot asymmetry test. We performed meta-regression analysis for heterogeneity exploration and sensitivity analysis for the publication bias. RESULTS: Overall, six studies including 298 patients were included in this review, of whom 149 (50%) were fluid responsive. The cutoff values of ΔEtCO2 in four studies was 5%, one was 5.8% and the other one was an absolute increase 2 mmHg. Heterogeneity between studies was assessed with an overall Q = 4.098, I(2) = 51%, and P = 0.064. The pooled sensitivity and specificity for the overall population were 0.79 (95% CI 0.72–0.85) and 0.90 (95% CI 0.77–0.96), respectively. The DOR was 35 (95% CI 12–107). The pooled AUROC was 0.81 (95% CI 0.77–0.84). On meta-regression analysis, the number of patients was sources of heterogeneity. The sensitivity analysis showed that the pooled DOR ranged from 21 to 140 and the pooled AUC ranged from 0.92 to 0.96 when one study was omitted. CONCLUSIONS: Though the limited number of studies included and study heterogeneity, our meta-analysis confirmed that the ΔEtCO2 performed moderately in predicting fluid responsiveness during the PLR test in patients with mechanical ventilation. BioMed Central 2022-01-14 /pmc/articles/PMC8760720/ /pubmed/35031070 http://dx.doi.org/10.1186/s13054-022-03890-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Huang, Haijun Wu, Chenxia Shen, Qinkang Fang, Yixin Xu, Hua Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis |
title | Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis |
title_full | Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis |
title_fullStr | Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis |
title_full_unstemmed | Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis |
title_short | Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis |
title_sort | value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8760720/ https://www.ncbi.nlm.nih.gov/pubmed/35031070 http://dx.doi.org/10.1186/s13054-022-03890-9 |
work_keys_str_mv | AT huanghaijun valueofvariationofendtidalcarbondioxideforpredictingfluidresponsivenessduringthepassivelegraisingtestinpatientswithmechanicalventilationasystematicreviewandmetaanalysis AT wuchenxia valueofvariationofendtidalcarbondioxideforpredictingfluidresponsivenessduringthepassivelegraisingtestinpatientswithmechanicalventilationasystematicreviewandmetaanalysis AT shenqinkang valueofvariationofendtidalcarbondioxideforpredictingfluidresponsivenessduringthepassivelegraisingtestinpatientswithmechanicalventilationasystematicreviewandmetaanalysis AT fangyixin valueofvariationofendtidalcarbondioxideforpredictingfluidresponsivenessduringthepassivelegraisingtestinpatientswithmechanicalventilationasystematicreviewandmetaanalysis AT xuhua valueofvariationofendtidalcarbondioxideforpredictingfluidresponsivenessduringthepassivelegraisingtestinpatientswithmechanicalventilationasystematicreviewandmetaanalysis |