Cargando…

Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance

OBJECTIVES: The authors developed a fully automated framework to quantify myocardial blood flow (MBF) from contrast-enhanced cardiac magnetic resonance (CMR) perfusion imaging and evaluated its diagnostic performance in patients. BACKGROUND: Fully quantitative CMR perfusion pixel maps were previousl...

Descripción completa

Detalles Bibliográficos
Autores principales: Hsu, Li-Yueh, Jacobs, Matthew, Benovoy, Mitchel, Ta, Allison D., Conn, Hannah M., Winkler, Susanne, Greve, Anders M., Chen, Marcus Y., Shanbhag, Sujata M., Bandettini, W. Patricia, Arai, Andrew E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8760891/
https://www.ncbi.nlm.nih.gov/pubmed/29454767
http://dx.doi.org/10.1016/j.jcmg.2018.01.005
_version_ 1784633416797388800
author Hsu, Li-Yueh
Jacobs, Matthew
Benovoy, Mitchel
Ta, Allison D.
Conn, Hannah M.
Winkler, Susanne
Greve, Anders M.
Chen, Marcus Y.
Shanbhag, Sujata M.
Bandettini, W. Patricia
Arai, Andrew E.
author_facet Hsu, Li-Yueh
Jacobs, Matthew
Benovoy, Mitchel
Ta, Allison D.
Conn, Hannah M.
Winkler, Susanne
Greve, Anders M.
Chen, Marcus Y.
Shanbhag, Sujata M.
Bandettini, W. Patricia
Arai, Andrew E.
author_sort Hsu, Li-Yueh
collection PubMed
description OBJECTIVES: The authors developed a fully automated framework to quantify myocardial blood flow (MBF) from contrast-enhanced cardiac magnetic resonance (CMR) perfusion imaging and evaluated its diagnostic performance in patients. BACKGROUND: Fully quantitative CMR perfusion pixel maps were previously validated with microsphere MBF measurements and showed potential in clinical applications, but the methods required laborious manual processes and were excessively time-consuming. METHODS: CMR perfusion imaging was performed on 80 patients with known or suspected coronary artery disease (CAD) and 17 healthy volunteers. Significant CAD was defined by quantitative coronary angiography (QCA) as ≥70% stenosis. Nonsignificant CAD was defined by: 1) QCA as <70% stenosis; or 2) coronary computed tomography angiography as <30% stenosis and a calcium score of 0 in all vessels. Automatically generated MBF maps were compared with manual quantification on healthy volunteers. Diagnostic performance of the automated MBF pixel maps was analyzed on patients using absolute MBF, myocardial perfusion reserve (MPR), and relative measurements of MBF and MPR. RESULTS: The correlation between automated and manual quantification was excellent (r = 0.96). Stress MBF and MPR in the ischemic zone were lower than those in the remote myocardium in patients with significant CAD (both p < 0.001). Stress MBF and MPR in the remote zone of the patients were lower than those in the normal volunteers (both p < 0.001). All quantitative metrics had good area under the curve (0.864 to 0.926), sensitivity (82.9% to 91.4%), and specificity (75.6% to 91.1%) on per-patient analysis. On a per-vessel analysis of the quantitative metrics, area under the curve (0.837 to 0.864), sensitivity (75.0% to 82.7%), and specificity (71.8% to 80.9%) were good. CONCLUSIONS: Fully quantitative CMR MBF pixel maps can be generated automatically, and the results agree well with manual quantification. These methods can discriminate regional perfusion variations and have high diagnostic performance for detecting significant CAD. (Technical Development of Cardiovascular Magnetic Resonance Imaging; NCT00027170)
format Online
Article
Text
id pubmed-8760891
institution National Center for Biotechnology Information
language English
publishDate 2018
record_format MEDLINE/PubMed
spelling pubmed-87608912022-01-15 Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance Hsu, Li-Yueh Jacobs, Matthew Benovoy, Mitchel Ta, Allison D. Conn, Hannah M. Winkler, Susanne Greve, Anders M. Chen, Marcus Y. Shanbhag, Sujata M. Bandettini, W. Patricia Arai, Andrew E. JACC Cardiovasc Imaging Article OBJECTIVES: The authors developed a fully automated framework to quantify myocardial blood flow (MBF) from contrast-enhanced cardiac magnetic resonance (CMR) perfusion imaging and evaluated its diagnostic performance in patients. BACKGROUND: Fully quantitative CMR perfusion pixel maps were previously validated with microsphere MBF measurements and showed potential in clinical applications, but the methods required laborious manual processes and were excessively time-consuming. METHODS: CMR perfusion imaging was performed on 80 patients with known or suspected coronary artery disease (CAD) and 17 healthy volunteers. Significant CAD was defined by quantitative coronary angiography (QCA) as ≥70% stenosis. Nonsignificant CAD was defined by: 1) QCA as <70% stenosis; or 2) coronary computed tomography angiography as <30% stenosis and a calcium score of 0 in all vessels. Automatically generated MBF maps were compared with manual quantification on healthy volunteers. Diagnostic performance of the automated MBF pixel maps was analyzed on patients using absolute MBF, myocardial perfusion reserve (MPR), and relative measurements of MBF and MPR. RESULTS: The correlation between automated and manual quantification was excellent (r = 0.96). Stress MBF and MPR in the ischemic zone were lower than those in the remote myocardium in patients with significant CAD (both p < 0.001). Stress MBF and MPR in the remote zone of the patients were lower than those in the normal volunteers (both p < 0.001). All quantitative metrics had good area under the curve (0.864 to 0.926), sensitivity (82.9% to 91.4%), and specificity (75.6% to 91.1%) on per-patient analysis. On a per-vessel analysis of the quantitative metrics, area under the curve (0.837 to 0.864), sensitivity (75.0% to 82.7%), and specificity (71.8% to 80.9%) were good. CONCLUSIONS: Fully quantitative CMR MBF pixel maps can be generated automatically, and the results agree well with manual quantification. These methods can discriminate regional perfusion variations and have high diagnostic performance for detecting significant CAD. (Technical Development of Cardiovascular Magnetic Resonance Imaging; NCT00027170) 2018-05 2018-02-14 /pmc/articles/PMC8760891/ /pubmed/29454767 http://dx.doi.org/10.1016/j.jcmg.2018.01.005 Text en https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
Hsu, Li-Yueh
Jacobs, Matthew
Benovoy, Mitchel
Ta, Allison D.
Conn, Hannah M.
Winkler, Susanne
Greve, Anders M.
Chen, Marcus Y.
Shanbhag, Sujata M.
Bandettini, W. Patricia
Arai, Andrew E.
Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance
title Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance
title_full Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance
title_fullStr Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance
title_full_unstemmed Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance
title_short Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance
title_sort diagnostic performance of fully automated pixel-wise quantitative myocardial perfusion imaging by cardiovascular magnetic resonance
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8760891/
https://www.ncbi.nlm.nih.gov/pubmed/29454767
http://dx.doi.org/10.1016/j.jcmg.2018.01.005
work_keys_str_mv AT hsuliyueh diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT jacobsmatthew diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT benovoymitchel diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT taallisond diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT connhannahm diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT winklersusanne diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT greveandersm diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT chenmarcusy diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT shanbhagsujatam diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT bandettiniwpatricia diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance
AT araiandrewe diagnosticperformanceoffullyautomatedpixelwisequantitativemyocardialperfusionimagingbycardiovascularmagneticresonance