The “Defibrillation Testing, Why Not?” survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice()

BACKGROUND: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter–defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended...

Descripción completa

Detalles Bibliográficos
Autores principales: Migliore, Federico, Viani, Stefano, Ziacchi, Matteo, Ottaviano, Luca, Francia, Pietro, Bianchi, Valter, De Bonis, Silvana, De Filippo, Paolo, Tola, Gianfranco, Vicentini, Alessandro, Taravelli, Erika, Calvi, Valeria Ilia, Lovecchio, Mariolina, Valsecchi, Sergio, Botto, Giovanni Luca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8761693/
https://www.ncbi.nlm.nih.gov/pubmed/35071727
http://dx.doi.org/10.1016/j.ijcha.2022.100952
_version_ 1784633587637682176
author Migliore, Federico
Viani, Stefano
Ziacchi, Matteo
Ottaviano, Luca
Francia, Pietro
Bianchi, Valter
De Bonis, Silvana
De Filippo, Paolo
Tola, Gianfranco
Vicentini, Alessandro
Taravelli, Erika
Calvi, Valeria Ilia
Lovecchio, Mariolina
Valsecchi, Sergio
Botto, Giovanni Luca
author_facet Migliore, Federico
Viani, Stefano
Ziacchi, Matteo
Ottaviano, Luca
Francia, Pietro
Bianchi, Valter
De Bonis, Silvana
De Filippo, Paolo
Tola, Gianfranco
Vicentini, Alessandro
Taravelli, Erika
Calvi, Valeria Ilia
Lovecchio, Mariolina
Valsecchi, Sergio
Botto, Giovanni Luca
author_sort Migliore, Federico
collection PubMed
description BACKGROUND: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter–defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended on implantation of subcutaneous ICD (S-ICD). The aim of the present survey was to analyze the current practice of DT during T-ICD and S-ICD implantations. METHODS: In March 2021, an ad hoc questionnaire on the current performance of DT and the standard practice adopted during testing was completed at 72 Italian centers implanting S-ICD and T-ICD. RESULTS: 48 (67%) operators reported never performing DT during de-novo T-ICD implantations, while no operators perform it systematically. The remaining respondents perform it for patients at risk for a high defibrillation threshold. DT is never performed at T-ICD generator change. At the time of de-novo S-ICD implantation, DT is never performed by 9 (13%) operators and performed systematically by 48 (66%). The remaining operators frequently omit DT in patients with more severe systolic dysfunction. DT is not performed at S-ICD generator change by 92% of operators. DT is conducted by delivering a first shock energy of 65 J by 60% of operators, while the remaining 40% test lower energy values. CONCLUSIONS: In current clinical practice, most operators omit DT at T-ICD implantation, even when still recommended in the guidelines. DT is also frequently omitted at S-ICD implantation, and a wide variability exists among operators in the procedures followed during DT.
format Online
Article
Text
id pubmed-8761693
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-87616932022-01-20 The “Defibrillation Testing, Why Not?” survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice() Migliore, Federico Viani, Stefano Ziacchi, Matteo Ottaviano, Luca Francia, Pietro Bianchi, Valter De Bonis, Silvana De Filippo, Paolo Tola, Gianfranco Vicentini, Alessandro Taravelli, Erika Calvi, Valeria Ilia Lovecchio, Mariolina Valsecchi, Sergio Botto, Giovanni Luca Int J Cardiol Heart Vasc Original Paper BACKGROUND: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter–defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended on implantation of subcutaneous ICD (S-ICD). The aim of the present survey was to analyze the current practice of DT during T-ICD and S-ICD implantations. METHODS: In March 2021, an ad hoc questionnaire on the current performance of DT and the standard practice adopted during testing was completed at 72 Italian centers implanting S-ICD and T-ICD. RESULTS: 48 (67%) operators reported never performing DT during de-novo T-ICD implantations, while no operators perform it systematically. The remaining respondents perform it for patients at risk for a high defibrillation threshold. DT is never performed at T-ICD generator change. At the time of de-novo S-ICD implantation, DT is never performed by 9 (13%) operators and performed systematically by 48 (66%). The remaining operators frequently omit DT in patients with more severe systolic dysfunction. DT is not performed at S-ICD generator change by 92% of operators. DT is conducted by delivering a first shock energy of 65 J by 60% of operators, while the remaining 40% test lower energy values. CONCLUSIONS: In current clinical practice, most operators omit DT at T-ICD implantation, even when still recommended in the guidelines. DT is also frequently omitted at S-ICD implantation, and a wide variability exists among operators in the procedures followed during DT. Elsevier 2022-01-11 /pmc/articles/PMC8761693/ /pubmed/35071727 http://dx.doi.org/10.1016/j.ijcha.2022.100952 Text en © 2022 The Authors. Published by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Paper
Migliore, Federico
Viani, Stefano
Ziacchi, Matteo
Ottaviano, Luca
Francia, Pietro
Bianchi, Valter
De Bonis, Silvana
De Filippo, Paolo
Tola, Gianfranco
Vicentini, Alessandro
Taravelli, Erika
Calvi, Valeria Ilia
Lovecchio, Mariolina
Valsecchi, Sergio
Botto, Giovanni Luca
The “Defibrillation Testing, Why Not?” survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice()
title The “Defibrillation Testing, Why Not?” survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice()
title_full The “Defibrillation Testing, Why Not?” survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice()
title_fullStr The “Defibrillation Testing, Why Not?” survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice()
title_full_unstemmed The “Defibrillation Testing, Why Not?” survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice()
title_short The “Defibrillation Testing, Why Not?” survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice()
title_sort “defibrillation testing, why not?” survey. testing of subcutaneous and transvenous defibrillators in the italian clinical practice()
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8761693/
https://www.ncbi.nlm.nih.gov/pubmed/35071727
http://dx.doi.org/10.1016/j.ijcha.2022.100952
work_keys_str_mv AT migliorefederico thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT vianistefano thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT ziacchimatteo thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT ottavianoluca thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT franciapietro thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT bianchivalter thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT debonissilvana thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT defilippopaolo thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT tolagianfranco thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT vicentinialessandro thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT taravellierika thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT calvivaleriailia thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT lovecchiomariolina thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT valsecchisergio thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT bottogiovanniluca thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT thedefibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT migliorefederico defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT vianistefano defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT ziacchimatteo defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT ottavianoluca defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT franciapietro defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT bianchivalter defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT debonissilvana defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT defilippopaolo defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT tolagianfranco defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT vicentinialessandro defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT taravellierika defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT calvivaleriailia defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT lovecchiomariolina defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT valsecchisergio defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT bottogiovanniluca defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice
AT defibrillationtestingwhynotsurveytestingofsubcutaneousandtransvenousdefibrillatorsintheitalianclinicalpractice