Quartz tuning forks resonance frequency matching for laser spectroscopy sensing

In this paper, we report on the performance of quartz tuning fork (QTF) based laser spectroscopy sensing employing multiple QTFs. To avoid that resonance frequency mismatching of the QTFs degrades the sensor performance, two types of resonance frequency matching method are here proposed. A system ba...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Yufei, Hu, Yinqiu, Qiao, Shunda, Lang, Ziting, Liu, Xiaonan, He, Ying, Spagnolo, Vincenzo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8762071/
https://www.ncbi.nlm.nih.gov/pubmed/35070687
http://dx.doi.org/10.1016/j.pacs.2022.100329
_version_ 1784633679945924608
author Ma, Yufei
Hu, Yinqiu
Qiao, Shunda
Lang, Ziting
Liu, Xiaonan
He, Ying
Spagnolo, Vincenzo
author_facet Ma, Yufei
Hu, Yinqiu
Qiao, Shunda
Lang, Ziting
Liu, Xiaonan
He, Ying
Spagnolo, Vincenzo
author_sort Ma, Yufei
collection PubMed
description In this paper, we report on the performance of quartz tuning fork (QTF) based laser spectroscopy sensing employing multiple QTFs. To avoid that resonance frequency mismatching of the QTFs degrades the sensor performance, two types of resonance frequency matching method are here proposed. A system based on the coupling of two sensing modules, one based on quartz-enhanced photoacoustic spectroscopy (QEPAS) and one on light-induced thermoelastic spectroscopy (LITES) technique, was realized to validate the proposed methods. Each module employed a different QTF (QTF1 and QTF2, respectively). Operating temperature or pressure of QTF2 were regulated to match the resonance frequency of QTF1, which operated at 25.0 °C and atmospheric pressure. Without regulation, the difference between QTF1 and QTF2 resonance frequencies was 2.42 Hz and the superposition coefficient η was only 54.7%. When the temperature regulation was carried out, at a QTF2 operating temperature of 67.5 °C, an optimal η value of 95.0% was obtained. For the pressure regulation approach, if operating QTF2 at pressure of 500 Torr, η reached a value of 97.2%. The obtained results show that the proposed two methods are effective in resonance frequency matching of QTFs for gas sensing systems.
format Online
Article
Text
id pubmed-8762071
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-87620712022-01-20 Quartz tuning forks resonance frequency matching for laser spectroscopy sensing Ma, Yufei Hu, Yinqiu Qiao, Shunda Lang, Ziting Liu, Xiaonan He, Ying Spagnolo, Vincenzo Photoacoustics Research Article In this paper, we report on the performance of quartz tuning fork (QTF) based laser spectroscopy sensing employing multiple QTFs. To avoid that resonance frequency mismatching of the QTFs degrades the sensor performance, two types of resonance frequency matching method are here proposed. A system based on the coupling of two sensing modules, one based on quartz-enhanced photoacoustic spectroscopy (QEPAS) and one on light-induced thermoelastic spectroscopy (LITES) technique, was realized to validate the proposed methods. Each module employed a different QTF (QTF1 and QTF2, respectively). Operating temperature or pressure of QTF2 were regulated to match the resonance frequency of QTF1, which operated at 25.0 °C and atmospheric pressure. Without regulation, the difference between QTF1 and QTF2 resonance frequencies was 2.42 Hz and the superposition coefficient η was only 54.7%. When the temperature regulation was carried out, at a QTF2 operating temperature of 67.5 °C, an optimal η value of 95.0% was obtained. For the pressure regulation approach, if operating QTF2 at pressure of 500 Torr, η reached a value of 97.2%. The obtained results show that the proposed two methods are effective in resonance frequency matching of QTFs for gas sensing systems. Elsevier 2022-01-11 /pmc/articles/PMC8762071/ /pubmed/35070687 http://dx.doi.org/10.1016/j.pacs.2022.100329 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Ma, Yufei
Hu, Yinqiu
Qiao, Shunda
Lang, Ziting
Liu, Xiaonan
He, Ying
Spagnolo, Vincenzo
Quartz tuning forks resonance frequency matching for laser spectroscopy sensing
title Quartz tuning forks resonance frequency matching for laser spectroscopy sensing
title_full Quartz tuning forks resonance frequency matching for laser spectroscopy sensing
title_fullStr Quartz tuning forks resonance frequency matching for laser spectroscopy sensing
title_full_unstemmed Quartz tuning forks resonance frequency matching for laser spectroscopy sensing
title_short Quartz tuning forks resonance frequency matching for laser spectroscopy sensing
title_sort quartz tuning forks resonance frequency matching for laser spectroscopy sensing
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8762071/
https://www.ncbi.nlm.nih.gov/pubmed/35070687
http://dx.doi.org/10.1016/j.pacs.2022.100329
work_keys_str_mv AT mayufei quartztuningforksresonancefrequencymatchingforlaserspectroscopysensing
AT huyinqiu quartztuningforksresonancefrequencymatchingforlaserspectroscopysensing
AT qiaoshunda quartztuningforksresonancefrequencymatchingforlaserspectroscopysensing
AT langziting quartztuningforksresonancefrequencymatchingforlaserspectroscopysensing
AT liuxiaonan quartztuningforksresonancefrequencymatchingforlaserspectroscopysensing
AT heying quartztuningforksresonancefrequencymatchingforlaserspectroscopysensing
AT spagnolovincenzo quartztuningforksresonancefrequencymatchingforlaserspectroscopysensing