Cargando…
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
BACKGROUND: This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixation on renal function. METHODS: Between May 2006 and January 2019, a total of 168 patients (135 males, 33 females; mean age: 75.2±8.4 years...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bayçınar Medical Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8762917/ https://www.ncbi.nlm.nih.gov/pubmed/35096439 http://dx.doi.org/10.5606/tgkdc.dergisi.2021.22110 |
_version_ | 1784633846635954176 |
---|---|
author | Sangtae, Choi Wonsuk, Lee Jinmo, Kang Doojin, Kim Daisik, Ko |
author_facet | Sangtae, Choi Wonsuk, Lee Jinmo, Kang Doojin, Kim Daisik, Ko |
author_sort | Sangtae, Choi |
collection | PubMed |
description | BACKGROUND: This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixation on renal function. METHODS: Between May 2006 and January 2019, a total of 168 patients (135 males, 33 females; mean age: 75.2±8.4 years; range, 48 to 93 years) who underwent endovascular aortic repair were retrospectively analyzed. To compare the effects of graft types, we measured the change in pararenal aortic diameter at four levels: below the celiac artery, below the superior mesenteric artery, at the lowest renal artery, and 1 cm below the lowest renal artery. To evaluate the effect of suprarenal fixation on renal function, serial measurements of serum creatinine, glomerular filtration rate, creatinine clearance rate, and estimated glomerular filtration rate were made. We examined the factors related to post-procedural aortic diameter. RESULTS: The mean change in the aortic diameter was statistically significant, being 12.9±10% in the suprarenal fixation group and 6.19±6.9% in the infrarenal fixation group only at the lowest renal artery level (p=0.001). There was no significant difference in the rate of type I endoleak (p=0.330) or renal function and adverse events (p>0.107) between the groups. The formula for calculating post-procedural aortic diameter was as follows: post-procedural aortic diameter (renal artery level, mm) =1.845 (in case of suprarenal fixation) + 1.012 × pre-procedural aortic diameter (renal artery level, mm) + 0.029 × follow-up time (months) + 0.039 × oversizing (%) (R2=0.773, p<0.001). CONCLUSION: Suprarenal fixation affects the infrarenal aortic diameter at the lowest renal artery level without significant type I endoleak. However, it does not result in significant renal dysfunction. Pre-procedural aortic diameter, computed tomography follow-up time, suprarenal fixation type, and stent oversizing are the only definite independent correlation factors for postprocedural aortic diameter. This formula can predict the change of aortic diameter after endovascular aortic repair. |
format | Online Article Text |
id | pubmed-8762917 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Bayçınar Medical Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-87629172022-01-27 Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair Sangtae, Choi Wonsuk, Lee Jinmo, Kang Doojin, Kim Daisik, Ko Turk Gogus Kalp Damar Cerrahisi Derg Original Article BACKGROUND: This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixation on renal function. METHODS: Between May 2006 and January 2019, a total of 168 patients (135 males, 33 females; mean age: 75.2±8.4 years; range, 48 to 93 years) who underwent endovascular aortic repair were retrospectively analyzed. To compare the effects of graft types, we measured the change in pararenal aortic diameter at four levels: below the celiac artery, below the superior mesenteric artery, at the lowest renal artery, and 1 cm below the lowest renal artery. To evaluate the effect of suprarenal fixation on renal function, serial measurements of serum creatinine, glomerular filtration rate, creatinine clearance rate, and estimated glomerular filtration rate were made. We examined the factors related to post-procedural aortic diameter. RESULTS: The mean change in the aortic diameter was statistically significant, being 12.9±10% in the suprarenal fixation group and 6.19±6.9% in the infrarenal fixation group only at the lowest renal artery level (p=0.001). There was no significant difference in the rate of type I endoleak (p=0.330) or renal function and adverse events (p>0.107) between the groups. The formula for calculating post-procedural aortic diameter was as follows: post-procedural aortic diameter (renal artery level, mm) =1.845 (in case of suprarenal fixation) + 1.012 × pre-procedural aortic diameter (renal artery level, mm) + 0.029 × follow-up time (months) + 0.039 × oversizing (%) (R2=0.773, p<0.001). CONCLUSION: Suprarenal fixation affects the infrarenal aortic diameter at the lowest renal artery level without significant type I endoleak. However, it does not result in significant renal dysfunction. Pre-procedural aortic diameter, computed tomography follow-up time, suprarenal fixation type, and stent oversizing are the only definite independent correlation factors for postprocedural aortic diameter. This formula can predict the change of aortic diameter after endovascular aortic repair. Bayçınar Medical Publishing 2021-10-20 /pmc/articles/PMC8762917/ /pubmed/35096439 http://dx.doi.org/10.5606/tgkdc.dergisi.2021.22110 Text en Copyright © 2021, Turkish Society of Cardiovascular Surgery https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Article Sangtae, Choi Wonsuk, Lee Jinmo, Kang Doojin, Kim Daisik, Ko Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair |
title | Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair |
title_full | Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair |
title_fullStr | Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair |
title_full_unstemmed | Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair |
title_short | Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair |
title_sort | effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8762917/ https://www.ncbi.nlm.nih.gov/pubmed/35096439 http://dx.doi.org/10.5606/tgkdc.dergisi.2021.22110 |
work_keys_str_mv | AT sangtaechoi effectofstentgraftfixationtypesonpararenalaorticdiameterandrenalfunctionafterendovascularaorticrepair AT wonsuklee effectofstentgraftfixationtypesonpararenalaorticdiameterandrenalfunctionafterendovascularaorticrepair AT jinmokang effectofstentgraftfixationtypesonpararenalaorticdiameterandrenalfunctionafterendovascularaorticrepair AT doojinkim effectofstentgraftfixationtypesonpararenalaorticdiameterandrenalfunctionafterendovascularaorticrepair AT daisikko effectofstentgraftfixationtypesonpararenalaorticdiameterandrenalfunctionafterendovascularaorticrepair |