Cargando…

Simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry

The use of quaternary ammonium compounds (QACs) as disinfectants has increased tremendously in the COVID-19 pandemic to inactivate Severe Acute Respiratory Syndrome Coronavirus type 2 (SARS-CoV2). Dialkyldimethylammonium halides represent a frequently used type among QACs. Different halide anions, e...

Descripción completa

Detalles Bibliográficos
Autores principales: Thalhamer, Bernhard, Guntner, Armin Sebastian, Buchberger, Wolfgang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Authors. Published by Elsevier B.V. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8763416/
https://www.ncbi.nlm.nih.gov/pubmed/35068626
http://dx.doi.org/10.1016/j.jaap.2022.105447
_version_ 1784633930608017408
author Thalhamer, Bernhard
Guntner, Armin Sebastian
Buchberger, Wolfgang
author_facet Thalhamer, Bernhard
Guntner, Armin Sebastian
Buchberger, Wolfgang
author_sort Thalhamer, Bernhard
collection PubMed
description The use of quaternary ammonium compounds (QACs) as disinfectants has increased tremendously in the COVID-19 pandemic to inactivate Severe Acute Respiratory Syndrome Coronavirus type 2 (SARS-CoV2). Dialkyldimethylammonium halides represent a frequently used type among QACs. Different halide anions, each ionically linked to the same quaternary ammonium cation, show clear differences in biocidal activity, toxicity and allergic potential. Likewise, the alkyl chain length at the ammonium cation induces different biocidal efficacy and toxicology. Therefore, the object of this research was to develop a rapid and reliable method for the detection of ammonium cation and halide anion in a single analytical run. For that purpose, a gas chromatography mass spectrometry (GC/MS) method was developed for QACs of the dialkyldimethylammonium type. Pyrolytic conversion of the QACs in the injector port of the gas chromatograph into volatile molecule species allows fast and reliable subsequent GC/MS analysis. The developed method is suited for the determination of both the quaternary ammonium cation and the corresponding halide anion in a single gas chromatographic run. The application of this method to bulk material and standard material of explicitly specified didecyldimethylammonium chloride revealed deviations from the manufacturer’s specifications in a range up to four-fifths. Furthermore, didecyldimethylammonium chloride was detected in a disinfectant that does not comply with the labeling requirement for biocidal ingredients. With the method presented, results can be obtained for disinfectants with minimum effort within seven minutes.
format Online
Article
Text
id pubmed-8763416
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Authors. Published by Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-87634162022-01-18 Simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry Thalhamer, Bernhard Guntner, Armin Sebastian Buchberger, Wolfgang J Anal Appl Pyrolysis Article The use of quaternary ammonium compounds (QACs) as disinfectants has increased tremendously in the COVID-19 pandemic to inactivate Severe Acute Respiratory Syndrome Coronavirus type 2 (SARS-CoV2). Dialkyldimethylammonium halides represent a frequently used type among QACs. Different halide anions, each ionically linked to the same quaternary ammonium cation, show clear differences in biocidal activity, toxicity and allergic potential. Likewise, the alkyl chain length at the ammonium cation induces different biocidal efficacy and toxicology. Therefore, the object of this research was to develop a rapid and reliable method for the detection of ammonium cation and halide anion in a single analytical run. For that purpose, a gas chromatography mass spectrometry (GC/MS) method was developed for QACs of the dialkyldimethylammonium type. Pyrolytic conversion of the QACs in the injector port of the gas chromatograph into volatile molecule species allows fast and reliable subsequent GC/MS analysis. The developed method is suited for the determination of both the quaternary ammonium cation and the corresponding halide anion in a single gas chromatographic run. The application of this method to bulk material and standard material of explicitly specified didecyldimethylammonium chloride revealed deviations from the manufacturer’s specifications in a range up to four-fifths. Furthermore, didecyldimethylammonium chloride was detected in a disinfectant that does not comply with the labeling requirement for biocidal ingredients. With the method presented, results can be obtained for disinfectants with minimum effort within seven minutes. The Authors. Published by Elsevier B.V. 2022-03 2022-01-18 /pmc/articles/PMC8763416/ /pubmed/35068626 http://dx.doi.org/10.1016/j.jaap.2022.105447 Text en © 2022 The Authors Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Thalhamer, Bernhard
Guntner, Armin Sebastian
Buchberger, Wolfgang
Simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry
title Simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry
title_full Simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry
title_fullStr Simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry
title_full_unstemmed Simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry
title_short Simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry
title_sort simultaneous analysis of quaternary ammonium cations and corresponding halide counterions by pyrolysis gas chromatography / mass spectrometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8763416/
https://www.ncbi.nlm.nih.gov/pubmed/35068626
http://dx.doi.org/10.1016/j.jaap.2022.105447
work_keys_str_mv AT thalhamerbernhard simultaneousanalysisofquaternaryammoniumcationsandcorrespondinghalidecounterionsbypyrolysisgaschromatographymassspectrometry
AT guntnerarminsebastian simultaneousanalysisofquaternaryammoniumcationsandcorrespondinghalidecounterionsbypyrolysisgaschromatographymassspectrometry
AT buchbergerwolfgang simultaneousanalysisofquaternaryammoniumcationsandcorrespondinghalidecounterionsbypyrolysisgaschromatographymassspectrometry