Cargando…

Retrieval of a Dislocated Stent Using a Grasping Forceps and a Steerable Sheath in a Fontan Patient

In Fontan patients, any pulmonary stenosis may impede free passive inflow into the pulmonary circuit and elevate central venous pressure. When stenting such pulmonary stenosis, dislocation of a stent is a feared complication. Here, we report on a successful retrieval of a dislocated Cook Formula ste...

Descripción completa

Detalles Bibliográficos
Autores principales: Kehl, Torben, Müller, Götz, Rickers, Carsten, Kozlik-Feldmann, Rainer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8763580/
https://www.ncbi.nlm.nih.gov/pubmed/35059279
http://dx.doi.org/10.1055/s-0041-1736207
_version_ 1784633975737679872
author Kehl, Torben
Müller, Götz
Rickers, Carsten
Kozlik-Feldmann, Rainer
author_facet Kehl, Torben
Müller, Götz
Rickers, Carsten
Kozlik-Feldmann, Rainer
author_sort Kehl, Torben
collection PubMed
description In Fontan patients, any pulmonary stenosis may impede free passive inflow into the pulmonary circuit and elevate central venous pressure. When stenting such pulmonary stenosis, dislocation of a stent is a feared complication. Here, we report on a successful retrieval of a dislocated Cook Formula stent into the peripheral left pulmonary artery in a Fontan patient with protein-losing enteropathy using a steerable sheath and a grasping forceps. Furthermore, a successful stent implantation for treating the stenosis was possible. Subsequently, we simulated the retraction technique ex vivo. To manage stent dislocation during complex pediatric catheter interventions, we can recommend the use of a steerable sheath guiding a grasping forceps. A dislocated stent can be grasped, completely longitudinally refolded, and safely retrieved.
format Online
Article
Text
id pubmed-8763580
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-87635802022-01-19 Retrieval of a Dislocated Stent Using a Grasping Forceps and a Steerable Sheath in a Fontan Patient Kehl, Torben Müller, Götz Rickers, Carsten Kozlik-Feldmann, Rainer Thorac Cardiovasc Surg Rep In Fontan patients, any pulmonary stenosis may impede free passive inflow into the pulmonary circuit and elevate central venous pressure. When stenting such pulmonary stenosis, dislocation of a stent is a feared complication. Here, we report on a successful retrieval of a dislocated Cook Formula stent into the peripheral left pulmonary artery in a Fontan patient with protein-losing enteropathy using a steerable sheath and a grasping forceps. Furthermore, a successful stent implantation for treating the stenosis was possible. Subsequently, we simulated the retraction technique ex vivo. To manage stent dislocation during complex pediatric catheter interventions, we can recommend the use of a steerable sheath guiding a grasping forceps. A dislocated stent can be grasped, completely longitudinally refolded, and safely retrieved. Georg Thieme Verlag KG 2022-01-17 /pmc/articles/PMC8763580/ /pubmed/35059279 http://dx.doi.org/10.1055/s-0041-1736207 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Kehl, Torben
Müller, Götz
Rickers, Carsten
Kozlik-Feldmann, Rainer
Retrieval of a Dislocated Stent Using a Grasping Forceps and a Steerable Sheath in a Fontan Patient
title Retrieval of a Dislocated Stent Using a Grasping Forceps and a Steerable Sheath in a Fontan Patient
title_full Retrieval of a Dislocated Stent Using a Grasping Forceps and a Steerable Sheath in a Fontan Patient
title_fullStr Retrieval of a Dislocated Stent Using a Grasping Forceps and a Steerable Sheath in a Fontan Patient
title_full_unstemmed Retrieval of a Dislocated Stent Using a Grasping Forceps and a Steerable Sheath in a Fontan Patient
title_short Retrieval of a Dislocated Stent Using a Grasping Forceps and a Steerable Sheath in a Fontan Patient
title_sort retrieval of a dislocated stent using a grasping forceps and a steerable sheath in a fontan patient
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8763580/
https://www.ncbi.nlm.nih.gov/pubmed/35059279
http://dx.doi.org/10.1055/s-0041-1736207
work_keys_str_mv AT kehltorben retrievalofadislocatedstentusingagraspingforcepsandasteerablesheathinafontanpatient
AT mullergotz retrievalofadislocatedstentusingagraspingforcepsandasteerablesheathinafontanpatient
AT rickerscarsten retrievalofadislocatedstentusingagraspingforcepsandasteerablesheathinafontanpatient
AT kozlikfeldmannrainer retrievalofadislocatedstentusingagraspingforcepsandasteerablesheathinafontanpatient