Cargando…

Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes

PURPOSE: To evaluate the frequency of and identify the factors that influence the artifacts of swept-source optical coherence tomography angiography (SS-OCTA) in glaucomatous and normal eyes. METHODS: Artifacts of OCTA images of open-angle glaucoma (OAG) and normal subjects were analyzed using SS-OC...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Weijing, Song, Yunhe, Lin, Fengbin, Xiong, Jian, Li, Fei, Jin, Ling, Wang, Zhenyu, Yang, Chunman, Yang, Bin, Wang, Fanyin, Ning, Guili, Wang, Wei, Zhang, Xiulan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8764211/
https://www.ncbi.nlm.nih.gov/pubmed/35040917
http://dx.doi.org/10.1167/tvst.11.1.23
_version_ 1784634114615279616
author Cheng, Weijing
Song, Yunhe
Lin, Fengbin
Xiong, Jian
Li, Fei
Jin, Ling
Wang, Zhenyu
Yang, Chunman
Yang, Bin
Wang, Fanyin
Ning, Guili
Wang, Wei
Zhang, Xiulan
author_facet Cheng, Weijing
Song, Yunhe
Lin, Fengbin
Xiong, Jian
Li, Fei
Jin, Ling
Wang, Zhenyu
Yang, Chunman
Yang, Bin
Wang, Fanyin
Ning, Guili
Wang, Wei
Zhang, Xiulan
author_sort Cheng, Weijing
collection PubMed
description PURPOSE: To evaluate the frequency of and identify the factors that influence the artifacts of swept-source optical coherence tomography angiography (SS-OCTA) in glaucomatous and normal eyes. METHODS: Artifacts of OCTA images of open-angle glaucoma (OAG) and normal subjects were analyzed using SS-OCTA. Univariate and multivariate logistic regression analyses were performed to evaluate the association of age, sex, best-corrected visual acuity, axial length (AL), intraocular pressure, presence and severity of OAG, and image quality score (IQS) with the presence of artifacts. RESULTS: Images from 4426 subjects were included in the study. At least one type of artifact was present in 24.54% of the images. The most common artifacts were occurrence of motion (705 eyes, 15.93%), followed by defocus (628 eyes, 14.19%), decentration (134 eyes, 3.03%), masking (62 eyes,1.40%), and segmentation errors (23 eyes, 0.52%). Multivariate logistic analyses showed that the presence of OAG (odds ratio [OR] = 2.71; 95% confidence interval [CI], 2.09–3.51; P < 0.001), female sex (OR = 1.34; 95% CI, 1.12–1.61; P = 0.001), longer AL (OR = 1.09; 95% CI, 1.02–1.17; P = 0.017), and IQS < 40 (OR = 3.75; 95% CI, 3.15–4.48; P < 0.001) were significantly associated with higher odds for the presence of any artifact. The IQS had poor performance for detecting artifacts, with an area under the curve of 0.723, sensitivity of 73.04%, and specificity of 62.53%. CONCLUSIONS: OAG eyes had more SS-OCTA image artifacts than normal eyes. IQS is an imperfect tool for identifying artifacts. TRANSLATIONAL RELEVANCE: Special attention should be paid to the effect of artifacts when using SS-OCTA in the clinical setting to assess vascular parameters in patients with glaucoma.
format Online
Article
Text
id pubmed-8764211
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-87642112022-01-26 Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes Cheng, Weijing Song, Yunhe Lin, Fengbin Xiong, Jian Li, Fei Jin, Ling Wang, Zhenyu Yang, Chunman Yang, Bin Wang, Fanyin Ning, Guili Wang, Wei Zhang, Xiulan Transl Vis Sci Technol Article PURPOSE: To evaluate the frequency of and identify the factors that influence the artifacts of swept-source optical coherence tomography angiography (SS-OCTA) in glaucomatous and normal eyes. METHODS: Artifacts of OCTA images of open-angle glaucoma (OAG) and normal subjects were analyzed using SS-OCTA. Univariate and multivariate logistic regression analyses were performed to evaluate the association of age, sex, best-corrected visual acuity, axial length (AL), intraocular pressure, presence and severity of OAG, and image quality score (IQS) with the presence of artifacts. RESULTS: Images from 4426 subjects were included in the study. At least one type of artifact was present in 24.54% of the images. The most common artifacts were occurrence of motion (705 eyes, 15.93%), followed by defocus (628 eyes, 14.19%), decentration (134 eyes, 3.03%), masking (62 eyes,1.40%), and segmentation errors (23 eyes, 0.52%). Multivariate logistic analyses showed that the presence of OAG (odds ratio [OR] = 2.71; 95% confidence interval [CI], 2.09–3.51; P < 0.001), female sex (OR = 1.34; 95% CI, 1.12–1.61; P = 0.001), longer AL (OR = 1.09; 95% CI, 1.02–1.17; P = 0.017), and IQS < 40 (OR = 3.75; 95% CI, 3.15–4.48; P < 0.001) were significantly associated with higher odds for the presence of any artifact. The IQS had poor performance for detecting artifacts, with an area under the curve of 0.723, sensitivity of 73.04%, and specificity of 62.53%. CONCLUSIONS: OAG eyes had more SS-OCTA image artifacts than normal eyes. IQS is an imperfect tool for identifying artifacts. TRANSLATIONAL RELEVANCE: Special attention should be paid to the effect of artifacts when using SS-OCTA in the clinical setting to assess vascular parameters in patients with glaucoma. The Association for Research in Vision and Ophthalmology 2022-01-18 /pmc/articles/PMC8764211/ /pubmed/35040917 http://dx.doi.org/10.1167/tvst.11.1.23 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Cheng, Weijing
Song, Yunhe
Lin, Fengbin
Xiong, Jian
Li, Fei
Jin, Ling
Wang, Zhenyu
Yang, Chunman
Yang, Bin
Wang, Fanyin
Ning, Guili
Wang, Wei
Zhang, Xiulan
Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes
title Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes
title_full Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes
title_fullStr Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes
title_full_unstemmed Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes
title_short Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes
title_sort assessment of artifacts in swept-source optical coherence tomography angiography for glaucomatous and normal eyes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8764211/
https://www.ncbi.nlm.nih.gov/pubmed/35040917
http://dx.doi.org/10.1167/tvst.11.1.23
work_keys_str_mv AT chengweijing assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT songyunhe assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT linfengbin assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT xiongjian assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT lifei assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT jinling assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT wangzhenyu assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT yangchunman assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT yangbin assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT wangfanyin assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT ningguili assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT wangwei assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes
AT zhangxiulan assessmentofartifactsinsweptsourceopticalcoherencetomographyangiographyforglaucomatousandnormaleyes