Cargando…

Effects of Revision Rod Position on Spinal Construct Stability in Lumbar Revision Surgery: A Finite Element Study

Revision surgery (RS) is a necessary surgical intervention in clinical practice to treat spinal instrumentation–related symptomatic complications. Three constructs with different configurations have been applied in RS. One distinguishing characteristic of these configurations is that the revision ro...

Descripción completa

Detalles Bibliográficos
Autores principales: Tan, Quan-Chang, Huang, Jin-Feng, Bai, Hao, Liu, Zi-Xuan, Huang, Xin-Yi, Zhao, Xiong, Yang, Zhao, Du, Cheng-Fei, Lei, Wei, Wu, Zi-Xiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8766337/
https://www.ncbi.nlm.nih.gov/pubmed/35071208
http://dx.doi.org/10.3389/fbioe.2021.799727
_version_ 1784634507066867712
author Tan, Quan-Chang
Huang, Jin-Feng
Bai, Hao
Liu, Zi-Xuan
Huang, Xin-Yi
Zhao, Xiong
Yang, Zhao
Du, Cheng-Fei
Lei, Wei
Wu, Zi-Xiang
author_facet Tan, Quan-Chang
Huang, Jin-Feng
Bai, Hao
Liu, Zi-Xuan
Huang, Xin-Yi
Zhao, Xiong
Yang, Zhao
Du, Cheng-Fei
Lei, Wei
Wu, Zi-Xiang
author_sort Tan, Quan-Chang
collection PubMed
description Revision surgery (RS) is a necessary surgical intervention in clinical practice to treat spinal instrumentation–related symptomatic complications. Three constructs with different configurations have been applied in RS. One distinguishing characteristic of these configurations is that the revision rods connecting previous segments and revision segments are placed alongside, outside, or inside the previous rods at the level of facetectomy. Whether the position of the revision rod could generate mechanical disparities in revision constructs is unknown. The objective of this study was to assess the influence of the revision rod position on the construct after RS. A validated spinal finite element (FE) model was developed to simulate RS after previous instrumented fusion using a modified dual-rod construct (DRCm), satellite-rod construct (SRC), and cortical bone trajectory construct (CBTC). Thereafter, maximum von Mises stress (VMS) on the annulus fibrosus and cages and the ligament force of the interspinous ligament, supraspinous ligament, and ligamentum flavum under a pure moment load and a follower load in six directions were applied to assess the influence of the revision rod position on the revision construct. An approximately identical overall reducing tendency of VMS was observed among the three constructs. The changing tendency of the maximum VMS on the cages placed at L4-L5 was nearly equal among the three constructs. However, the changing tendency of the maximum VMS on the cage placed at L2-L3 was notable, especially in the CBTC under right bending and left axial rotation. The overall changing tendency of the ligament force in the DRCm, SRC, and CBTC was also approximately equal, while the ligament force of the CBTC was found to be significantly greater than that of the DRCm and SRC at L1-L2. The results indicated that the stiffness associated with the CBTC might be lower than that associated with the DRCm and SRC in RS. The results of the present study indicated that the DRCm, SRC, and CBTC could provide sufficient stabilization in RS. The CBTC was a less rigid construct. Rather than the revision rod position, the method of constructing spinal instrumentation played a role in influencing the biomechanics of revision.
format Online
Article
Text
id pubmed-8766337
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87663372022-01-20 Effects of Revision Rod Position on Spinal Construct Stability in Lumbar Revision Surgery: A Finite Element Study Tan, Quan-Chang Huang, Jin-Feng Bai, Hao Liu, Zi-Xuan Huang, Xin-Yi Zhao, Xiong Yang, Zhao Du, Cheng-Fei Lei, Wei Wu, Zi-Xiang Front Bioeng Biotechnol Bioengineering and Biotechnology Revision surgery (RS) is a necessary surgical intervention in clinical practice to treat spinal instrumentation–related symptomatic complications. Three constructs with different configurations have been applied in RS. One distinguishing characteristic of these configurations is that the revision rods connecting previous segments and revision segments are placed alongside, outside, or inside the previous rods at the level of facetectomy. Whether the position of the revision rod could generate mechanical disparities in revision constructs is unknown. The objective of this study was to assess the influence of the revision rod position on the construct after RS. A validated spinal finite element (FE) model was developed to simulate RS after previous instrumented fusion using a modified dual-rod construct (DRCm), satellite-rod construct (SRC), and cortical bone trajectory construct (CBTC). Thereafter, maximum von Mises stress (VMS) on the annulus fibrosus and cages and the ligament force of the interspinous ligament, supraspinous ligament, and ligamentum flavum under a pure moment load and a follower load in six directions were applied to assess the influence of the revision rod position on the revision construct. An approximately identical overall reducing tendency of VMS was observed among the three constructs. The changing tendency of the maximum VMS on the cages placed at L4-L5 was nearly equal among the three constructs. However, the changing tendency of the maximum VMS on the cage placed at L2-L3 was notable, especially in the CBTC under right bending and left axial rotation. The overall changing tendency of the ligament force in the DRCm, SRC, and CBTC was also approximately equal, while the ligament force of the CBTC was found to be significantly greater than that of the DRCm and SRC at L1-L2. The results indicated that the stiffness associated with the CBTC might be lower than that associated with the DRCm and SRC in RS. The results of the present study indicated that the DRCm, SRC, and CBTC could provide sufficient stabilization in RS. The CBTC was a less rigid construct. Rather than the revision rod position, the method of constructing spinal instrumentation played a role in influencing the biomechanics of revision. Frontiers Media S.A. 2022-01-05 /pmc/articles/PMC8766337/ /pubmed/35071208 http://dx.doi.org/10.3389/fbioe.2021.799727 Text en Copyright © 2022 Tan, Huang, Bai, Liu, Huang, Zhao, Yang, Du, Lei and Wu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Tan, Quan-Chang
Huang, Jin-Feng
Bai, Hao
Liu, Zi-Xuan
Huang, Xin-Yi
Zhao, Xiong
Yang, Zhao
Du, Cheng-Fei
Lei, Wei
Wu, Zi-Xiang
Effects of Revision Rod Position on Spinal Construct Stability in Lumbar Revision Surgery: A Finite Element Study
title Effects of Revision Rod Position on Spinal Construct Stability in Lumbar Revision Surgery: A Finite Element Study
title_full Effects of Revision Rod Position on Spinal Construct Stability in Lumbar Revision Surgery: A Finite Element Study
title_fullStr Effects of Revision Rod Position on Spinal Construct Stability in Lumbar Revision Surgery: A Finite Element Study
title_full_unstemmed Effects of Revision Rod Position on Spinal Construct Stability in Lumbar Revision Surgery: A Finite Element Study
title_short Effects of Revision Rod Position on Spinal Construct Stability in Lumbar Revision Surgery: A Finite Element Study
title_sort effects of revision rod position on spinal construct stability in lumbar revision surgery: a finite element study
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8766337/
https://www.ncbi.nlm.nih.gov/pubmed/35071208
http://dx.doi.org/10.3389/fbioe.2021.799727
work_keys_str_mv AT tanquanchang effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy
AT huangjinfeng effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy
AT baihao effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy
AT liuzixuan effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy
AT huangxinyi effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy
AT zhaoxiong effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy
AT yangzhao effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy
AT duchengfei effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy
AT leiwei effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy
AT wuzixiang effectsofrevisionrodpositiononspinalconstructstabilityinlumbarrevisionsurgeryafiniteelementstudy